16 resultados para Responsive
em Cambridge University Engineering Department Publications Database
Resumo:
Computer modelling approaches have significant potential to enable decision-making about various aspects of responsive manufacturing. In order to understand the system prior to the selection of any responsiveness strategy, multiple process segments of organisations need to be modelled. The article presents a novel systematic approach for creating coherent sets of unified enterprise, simulation and other supporting models that collectively facilitate responsiveness. In this approach, enterprise models are used to explicitly define relatively enduring relationships between (i) production planning and control (PPC) processes, that implement a particular strategy and (ii) process-oriented elements of production systems, that are work loaded by the PPC processes. Coherent simulation models, can in part be derived from the enterprise models, so that they computer execute production system behaviours. In this way, time-based performance outcomes can be simulated; so that the impacts of alternative PPC strategies on the planning and controlling historical or forecasted patterns of workflow, through (current and possible future) production system models, can be analysed. The article describes the unified modelling approach conceived and its application in a furniture industry case study small and medium enterprise (SME). Copyright © 2010 Inderscience Enterprises Ltd.
Resumo:
Salmonella enterica sv. typhimurium (S. enterica sv. Typhimurium) has two metal-transporting P(1)-type ATPases whose actions largely overlap with respect to growth in elevated copper. Mutants lacking both ATPases over-accumulate copper relative to wild-type or either single mutant. Such duplication of ATPases is unusual in bacterial copper tolerance. Both ATPases are under the control of MerR family metal-responsive transcriptional activators. Analyses of periplasmic copper complexes identified copper-CueP as one of the predominant metal pools. Expression of cueP was recently shown to be controlled by the same metal-responsive activator as one of the P(1)-type ATPase genes (copA), and copper-CueP is a further atypical feature of copper homeostasis in S. enterica sv. Typhimurium. Elevated copper is detected by a reporter construct driven by the promoter of copA in wild-type S. enterica sv. Typhimurium during infection of macrophages. Double mutants missing both ATPases also show reduced survival inside cultured macrophages. It is hypothesized that elevated copper within macrophages may have selected for specialized copper-resistance systems in pathogenic microorganism such as S. enterica sv. Typhimurium.
Resumo:
A multi-disciplinary team based at Heriot-Watt University and other Universities has been set up to tackle the design and manufacturing of lab-on-a-chip for industries as one of the demonstrators of the EPSRC Grand Challenge project "3D-Mintegration". The team focuses on the analysis of foetal genetic material extracted from maternal blood as a smart alternative to invasive prenatal testing such as amniocentesis. The first module of the microsystem envisaged achieves a separation of blood cells from plasma. This system permits the testing of different manufacturing techniques.
Resumo:
The self-organization of the helical structure of chiral nematic liquid crystals combined with their sensitivity to electric fields makes them particularly interesting for low-threshold, wavelength tunable laser devices. We have studied these organic lasers in detail, ranging from the influence specific macroscopic properties, such as birefringence and order parameter, have on the output characteristics, to practical systems in the form of two-dimensional arrays, double-pass geometries and paintable lasers. Furthermore, even though chiral nematics are responsive to electric fields there is no facile means by which the helix periodicity can be adjusted, thereby allowing laser wavelength tuning, without adversely affecting the optical quality of the resonator. Therefore, in addition to studying the liquid crystal lasers, we have focused on finding a novel method with which to alter the periodicity of a chiral nematic using electric fields without inducing defects and degrading the optical quality factor of the resonator. This paper presents an overview of our research, describing (i) the correlation between laser output and material properties,(ii) the importance of the gain medium,(iii) multicolor laser arrays, and (iv) high slope efficiency (>60%) silicon back-plane devices. Overall we conclude that these materials have great potential for use in versatile organic laser systems.
Resumo:
Driven by the need for more responsive manufacturing processes and as a consequence of increasing complexity in products and production systems, this short paper introduces a number of developments in the area of modular, distributed manufacturing systems. Requirements for the development of such systems are addressed and, in particular, the relevance to current and future integrated control systems is examined. One of the key issues for integrated control systems in the future is the need to provide support for distributed decision-making in addition to existing distributed control capabilities.
Resumo:
We describe a methods of locating an RFID tag. One method comprises: transmitting tag location signals from a plurality of different transmit antennas, wherein said antennas are spaced apart by more than a near field limit distance at a frequency of a said signal; receiving a corresponding plurality of receiving return signals from said tag; and processing said tag return signals to determine a range to said tag; wherein said transmitting comprises transmitting at a plurality of different frequencies; wherein said processing comprises determining a phase difference at said plurality of different frequencies to determine said range, and wherein said determining of said phase difference determines a phase difference between either i) two or more of said transmit signals resulting in a maxima in the returned signal RSSI or ii) a first transmit signal and its corresponding return signal; and wherein said determining of said range to said tag uses said return signals weighted responsive to a respective received signal strength of the return signal. Further data which may be used for averaging may be generated by using the above techniques along with changes in the polarisation state of the transmit and receive antennas and/or physical reconfiguration of the antennas (e.g. switch the transmit and receive elements).
Resumo:
Several agencies in the United Kingdom have interest in the water quality of old navigational canals that have fallen into disuse after the decline of commercial canal transportation. The interested agencies desired a model to predict the water quantity and quality of inland navigational canals in order to evaluate management options to address the issues in the natural streams to which they discharge. Inland navigational canals have unique drivers of their hydrology and water quality compared to either natural streams, irrigation canals, or larger navigational canals connected to seas or oceans. Water in an inland canal is typically sourced from a reservoir and artificially pumped to a summit reach; its movement downhill is controlled by the activity of boats and overflow weirs. Stagnant impoundments between locks, which might normally be expected to result in a decrease in the concentration of sediment-associated pollutants, actually have surprisingly high levels of sediment due to boat traffic. Algal growth in the stagnant reach can be high. This paper describes a canal model developed to simulate hydrology and water quality in inland navigational canals. This model was successfully applied to the Kennet and Avon Canal to predict hydrology, sediment generation and transport, and algal growth and transport. The model is responsive to external influences such as sunlight, temperature, nutrient concentrations, boat traffic, and runoff from the contributing catchment area.
Resumo:
We demonstrate the fabrication and integration of active microstructures based on composites of 3D carbon nanotube (CNT) frameworks and hydrogels. The alignment of the CNTs within the microstructures converts the isotropic expansion of the gel into a directed anisotropic motion. Actuation by a moisture-responsive gel is observed by changing the ambient humidity, and is predicted by a finite element model of the composite system. These shape changes are rapid and can be transduced electrically within a microfluidic channel, by measuring the resistance change across a CNT microstructure during expansion of the gel. Our results suggest that combinations of gels with aligned CNTs can be a platform for directing the actuation of gels and measuring their response to stimuli. © 2011 The Royal Society of Chemistry.
Resumo:
Film bulk acoustic resonators (FBARs) and solidly mounted resonators (SMRs) have the potential to significantly improve upon the sensitivity and minimum detection limit of traditional gravimetric sensors based on quartz crystal microbalances (QCMs) and surface acoustic wave resonators (SAWs). To date, neither FBAR nor SMR devices have been demonstrated to be superior to the other; hence the choice between them depends primarily on the users' ability to design/fabricate membranes and/or Bragg reflectors. In this work, it is shown that identically designed FBAR and SMR devices resonating at the same frequency exhibit different responsivities to mass loadings, Rm, and that the SMRs are less responsive than the FBARs. For the specific device design and resonant frequency (~2 GHz) of the resonators presented here, the FBARs' mass responsivity is ~20% greater than that of the SMRs', and although this value is not universal for all possible device designs, it clearly shows that FBAR devices should be favoured over SMRs in gravimetric sensing applications where the FBARs' fragility is not an issue. Numerical calculations based on Mason's model offer an insight into the physical mechanisms behind the greater FBARs responsivity, and it was shown that the Bragg reflector has an effect on the acoustic load at one of the facets of the piezoelectric films which is in turn responsible for the SMRs' lower responsivity to mass loadings. © 2013 Elsevier B.V.
Resumo:
The Responsive Particle Dynamics model is a very efficient method to account for the transient forces present in complex fluids, such as solutions of entangled polymers. This coarse-grained model considers a solution of particles that are made of a core and a corona. The cores typically interact through conservative interactions, while the coronae transiently penetrate each other to form short-lived temporary interactions, typically of entropic origin. In this study, we reformulate the resulting rheological model within the general framework of nonequilibrium thermodynamics called General Equation for the Nonequilibrium Reversible-Irreversible Coupling. This allows us to determine the consistency of the model, from a mechanistic and thermodynamic point of view, and to isolate the reversible and irreversible contributions to the dynamics of the model system. © 2012 Springer-Verlag Berlin Heidelberg.
Resumo:
The utilisation of thin film technology to develop film bulk acoustic resonators (FBARs) and solidly mounted resonators (SMRs), offers great potential to outperform the sensitivity and minimum detection limit of gravimetric sensors. Up to now, the choice between FBARs and SMRs depends primarily on the users' ability to design and fabricate Bragg reflectors and/or membranes, because neither of these two types of resonators has been demonstrated to be superior to the other. In the work reported here, it is shown that identically designed FBARs and SMRs resonating at the same frequency exhibit different responsitivities, Rm, to mass loadings, being the FBARs more responsive than the SMRs. For the specific device design and resonant frequency (∼2 GHz) of the resonators presented, FBARs' mass responsitivity is ∼20% greater than that of SMRs, and although this value should not be taken as universal for all possible device designs, it clearly indicates that FBAR devices should be favoured over SMRs in gravimetric sensing applications. © 2012 IEEE.
Resumo:
This tunable holographic sensor offers interrogation and a reporting transducer as well as an analyte-responsive hydrogel, rendering it label-free and reusable. A single 6 ns laser pulse is used to fabricate holographic sensors consisting of silver nanoparticles arranged periodically within a polymer film. The tunability of the sensor is demonstrated through pH sensing of artificial urine and validated through computational modeling. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Computational modelling and characterisation of nanoparticle-based tuneable photonic crystal sensors
Resumo:
Photonic crystals are materials that are used to control or manipulate the propagation of light through a medium for a desired application. Common fabrication methods to prepare photonic crystals are both costly and intricate. However, through a cost-effective laser-induced photochemical patterning, one-dimensional responsive and tuneable photonic crystals can easily be fabricated. These structures act as optical transducers and respond to external stimuli. These photonic crystals are generally made of a responsive hydrogel that can host metallic nanoparticles in the form of arrays. The hydrogel-based photonic crystal has the capability to alter its periodicity in situ but also recover its initial geometrical dimensions, thereby rendering it fully reversible and reusable. Such responsive photonic crystals have applications in various responsive and tuneable optical devices. In this study, we fabricated a pH-sensitive photonic crystal sensor through photochemical patterning and demonstrated computational simulations of the sensor through a finite element modelling technique in order to analyse its optical properties on varying the pattern and characteristics of the nanoparticle arrays within the responsive hydrogel matrix. Both simulations and experimental results show the wavelength tuneability of the sensor with good agreement. Various factors, including nanoparticle size and distribution within the hydrogel-based responsive matrices that directly affect the performance of the sensors, are also studied computationally. © 2014 The Royal Society of Chemistry.