54 resultados para Oscillatory bath
em Cambridge University Engineering Department Publications Database
Resumo:
The dynamics of a fluid in a vertical tube, subjected to an oscillatory pressure gradient, is studied experimentally for both a Newtonian and a viscoelastic shear-thinning fluid. Particle image velocimetry is used to determine the two-dimensional velocity fields in the vertical plane of the tube axis, in a range of driving amplitudes from 0.8 to 2.5 mm and of driving frequencies from 2.0 to 11.5 Hz. The Newtonian fluid exhibits a laminar flow regime, independent of the axial position, in the whole range of drivings. For the complex fluid, instead, the parallel shear flow regime exhibited at low amplitudes [Torralba, Phys. Rev. E 72, 016308 (2005)] becomes unstable at higher drivings against the formation of symmetric vortices, equally spaced along the tube. At even higher drivings the vortex structure itself becomes unstable, and complex nonsymmetric structures develop. Given that inertial effects remain negligible even at the hardest drivings (Re < 10(-1)), it is the complex rheology of the fluid that is responsible for the instabilities observed. The system studied represents an interesting example of the development of shear-induced instabilities in nonlinear complex fluids in purely parallel shear flow.
Resumo:
Globally unstable wakes with co-flow at intermediate Reynolds numbers are studied, to quantify important spatial regions for the development and control of the global instability. One region of high structural sensitivity is found close to the inlet for all wakes, in agreement with previous findings for cylinder wakes. A second, elongated region of high structural sensitivity is seen downstream of the first one for unconfined wakes at Re = 400. When base flow modifications are considered, a spatially oscillating sensitivity pattern is found inside the downstream high structural sensitivity region. This implies that the same change in the base flow can either destabilize or stabilize the flow, depending on the exact position where it is applied. It is shown that the sensitivity pattern remains unchanged for different choices of streamwise boundary conditions and numerical resolution. Actual base flow modifications are applied in selected configurations, and the linear global modes recomputed. It is confirmed that the linear global eigenvalues move according to the predicted sensitivity pattern for small amplitude base flow modifications, for which the theory applies. We also look at the implications of a small control cylinder on the flow. Only the upstream high sensitivity region proves to be robust in terms of control, but one should be careful not to disturb the flow in the downstream high sensitivity region, in order to achieve control. The findings can have direct implications on the numerical resolution requirements for wakes at higher Reynolds numbers. Furthermore, they provide one more possible explanation to why confined wakes have a more narrow frequency spectrum than unconfined wakes.
Resumo:
The prediction of turbulent oscillatory flow at around transitional Reynolds numbers is considered for an idealized electronics system. To assess the accuracy of turbulence models, comparison is made with measurements. A stochastic procedure is used to recover instantaneous velocity time traces from predictions. This procedure enables more direct comparison with turbulence intensity measurements which have not been filtered to remove the oscillatory flow component. Normal wall distances, required in some turbulence models, are evaluated using a modified Poisson equation based technique. A range of zero, one and two equation turbulence models are tested, including zonal and a non-linear eddy viscosity models. The non-linear and zonal models showed potential for accuracy improvements.
Resumo:
A novel method for obtaining information on the charge density of an immersed surface is presented. The technique uses focused ultrasound to excite oscillatory fluid motion in the plane of the solid-liquid interface, over a localised area. The displacement current (resulting from the motion of fluid-borne ions in the outer double-layer) is detected by electrodes in the liquid. The method is demonstrated as a means for monitoring protein adsorption, and for monitoring interactions between two different proteins. A second electrokinetic effect at the interface is identified, isolated from the first, and shown to provide additional information on the compressibility and charge density of the double-layer. © 2001 Elsevier Science B.V. All rights reserved.