42 resultados para Oscillating mirrors
em Cambridge University Engineering Department Publications Database
Resumo:
A combined experimental and numerical study of a transonic shock wave in a parallel walled duct subject to downstream pressure perturbations has been conducted. Experiments and simulations have been carried out with a shock strength of M∞ = 1.4 for pressure perturbation frequencies in the range 16-90 Hz. The dynamics of unsteady shock motion and the interaction structure between the unsteady transonic shock wave and the turbulent tunnel floor boundary layer have been investigated. It is found that the (experimentally measured) dynamics of shock motion are generally well predicted by the computational scheme, especially at relatively low (≈ 40 Hz) frequencies. However, at higher frequencies (≈ 90 Hz), some subtle differences between the shock dynamics measured in experiments and those predicted by Computational Fluid Dynamics (CFD) exist. There is evidence from experiments that variations in shock / boundary layer interaction (SBLI) structure caused by shock motion are responsible for a change in the nature of shock dynamics between low and high frequency. In contrast, numerical results at low and high frequencies do not differ significantly and this suggests that the numerical method is not fully capturing the physics of the unsteady flow. Possible reasons for this are considered and a number of areas where CFD is unable to replicate experimental observations are identified. Significantly, CFD predicts changes in SBLI structure due to shock motion that are much too large and this may explain why none of the subtle effects on shock dynamics seen in experiments occur in CFD. Further work developing numerical methods that demonstrate a more realistic sensitivity of SBLI structure to unsteady shock motion is required. Copyright © 2010 by P.J.K. Bruce.
Resumo:
Commercially available integrated compact fluorescent lamps (CFLs) use self-resonant ballasts on grounds of simplicity and cost. To understand how to improve ballast efficiency, it is necessary to quantify the losses. The losses occurring in these ballasts have been directly measured using a precision mini-calorimeter. In addition, a Pspice model has been used to simulate the performance of an 18 W integrated CFL. The lamp has been represented by a behavioural model and Jiles-Atherton equations were used to model the current transformer core. The total loss is in close agreement with measurements from the mini-calorimeter, confirming the accuracy of the model. The total loss was then disaggregated into component losses by simulation, showing that the output inductor is the primary source of loss, followed by the inverter switches. © 2011 The Institution of Engineering and Technology.