284 resultados para Mechanics, Applied.

em Cambridge University Engineering Department Publications Database


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of PC-based PD6493:1991 fracture assessment procedures has revealed that, under certain circumstances, flaws of different dimensions may be found as being limiting or critical for identical applied conditions. The main causes for multiple solutions are a steep applied stress gradient, residual stress relaxation and flaw re-characterisation. This work uses several case studies to illustrate some of the circumstances under which multiple solutions occurs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The peel test is commonly used to determine the strength of adhesive joints. In its simplest form, a thin flexible strip which has been bonded to a rigid surface is peeled from the substrate at a constant rate and the peeling force which is applied to the debonding surfaces by the tension in the tape is measured. Peeling can be carried out with the peel angle, i.e. the angle made by the peel force with the substrate surface, from any value above about 10° although peeling tests at 90 and 180° are most common. If the tape is sufficiently thin for its bending resistance to be negligibly small then as well as the debonding or decohesion energy associated with the adhesive in and around the point of separation, the relation between the peeling force and the peeling angle is influenced both by the mechanical properties of the tape and any pre-strain locked into the tape during its application to the substrate. The analytic solution for a tape material which can be idealised as elastic perfectly-plastic is well established. Here, we present a more general form of analysis, applicable in principle to any constitutive relation between tape load and tape extension. Non-linearity between load and extension is of increasing significance as the peel angle is decreased: the model presented is consistent with existing equations describing the failure of a lap joint between non-linear materials. The analysis also allows for energy losses within the adhesive layer which themselves may be influenced by both peel rate and peel angle. We have experimentally examined the application of this new analysis to several specific peeling cases including tapes of cellophane, poly-vinyl chloride and PTFE. © 2005 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

One-cell-thick monolayers are the simplest tissues in multicellular organisms, yet they fulfill critical roles in development and normal physiology. In early development, embryonic morphogenesis results largely from monolayer rearrangement and deformation due to internally generated forces. Later, monolayers act as physical barriers separating the internal environment from the exterior and must withstand externally applied forces. Though resisting and generating mechanical forces is an essential part of monolayer function, simple experimental methods to characterize monolayer mechanical properties are lacking. Here, we describe a system for tensile testing of freely suspended cultured monolayers that enables the examination of their mechanical behavior at multi-, uni-, and subcellular scales. Using this system, we provide measurements of monolayer elasticity and show that this is two orders of magnitude larger than the elasticity of their isolated cellular components. Monolayers could withstand more than a doubling in length before failing through rupture of intercellular junctions. Measurement of stress at fracture enabled a first estimation of the average force needed to separate cells within truly mature monolayers, approximately ninefold larger than measured in pairs of isolated cells. As in single cells, monolayer mechanical properties were strongly dependent on the integrity of the actin cytoskeleton, myosin, and intercellular adhesions interfacing adjacent cells. High magnification imaging revealed that keratin filaments became progressively stretched during extension, suggesting they participate in monolayer mechanics. This multiscale study of monolayer response to deformation enabled by our device provides the first quantitative investigation of the link between monolayer biology and mechanics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study is the first step in the psychoacoustic exploration of perceptual differences between the sounds of different violins. A method was used which enabled the same performance to be replayed on different "virtual violins," so that the relationships between acoustical characteristics of violins and perceived qualities could be explored. Recordings of real performances were made using a bridge-mounted force transducer, giving an accurate representation of the signal from the violin string. These were then played through filters corresponding to the admittance curves of different violins. Initially, limits of listener performance in detecting changes in acoustical characteristics were characterized. These consisted of shifts in frequency or increases in amplitude of single modes or frequency bands that have been proposed previously to be significant in the perception of violin sound quality. Thresholds were significantly lower for musically trained than for nontrained subjects but were not significantly affected by the violin used as a baseline. Thresholds for the musicians typically ranged from 3 to 6 dB for amplitude changes and 1.5%-20% for frequency changes. interpretation of the results using excitation patterns showed that thresholds for the best subjects were quite well predicted by a multichannel model based on optimal processing. (c) 2007 Acoustical Society of America.