35 resultados para MM TUBE

em Cambridge University Engineering Department Publications Database


Relevância:

20.00% 20.00%

Publicador:

Resumo:

As part of a study of the wear of candidate heat exchanger tube materials for use in fluidized bed combustors, two similar laboratory-scale rigs have been built and characterized. Specimens of selected alloys are carried on counter-rotating rotors immersed in a fluidized bed, and are exposed to particle impact velocities of up to approximately 3 ms-1 at temperatures up to 1000°C. The performance of this design of apparatus has been investigated in detail. The effects of several experimental variables have been studied, including angle of particle impact, specimen speed, position of the rotor within the fluidized bed, duration of exposure, bed material particle size, degradation of the bed material, degree of fluidization of the bed, and size of specimen. In many cases the results obtained with steel specimens at elevated temperatures are similar to those observed with polymeric specimens at low temperatures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hybrid quantum mechanics/molecular mechanics (QM/MM) simulations provide a powerful tool for studying chemical reactions, especially in complex biochemical systems. In most works to date, the quantum region is kept fixed throughout the simulation and is defined in an ad hoc way based on chemical intuition and available computational resources. The simulation errors associated with a given choice of the quantum region are, however, rarely assessed in a systematic manner. Here we study the dependence of two relevant quantities on the QM region size: the force error at the center of the QM region and the free energy of a proton transfer reaction. Taking lysozyme as our model system, we find that in an apolar region the average force error rapidly decreases with increasing QM region size. In contrast, the average force error at the polar active site is considerably higher, exhibits large oscillations and decreases more slowly, and may not fall below acceptable limits even for a quantum region radius of 9.0 A. Although computation of free energies could only be afforded until 6.0 A, results were found to change considerably within these limits. These errors demonstrate that the results of QM/MM calculations are heavily affected by the definition of the QM region (not only its size), and a convergence test is proposed to be a part of setting up QM/MM simulations.

Relevância:

20.00% 20.00%

Publicador: