23 resultados para Low Level light Therapy
em Cambridge University Engineering Department Publications Database
Resumo:
Laser ablation of solid Silicon targets using pulsed Yb fiber lasers of pulse duration 1.5-400 ns Yb fiber lasers is studied in this work. Material responses of a range of pulse envelopes are examined including front peak (FP) and double peak (DP) pulses. Theoretical models for the interactions are examined and qualitative explanations of material response experiments are presented.
Resumo:
Motor control strongly relies on neural processes that predict the sensory consequences of self-generated actions. Previous research has demonstrated deficits in such sensory-predictive processes in schizophrenic patients and these low-level deficits are thought to contribute to the emergence of delusions of control. Here, we examined the extent to which individual differences in sensory prediction are associated with a tendency towards delusional ideation in healthy participants. We used a force-matching task to quantify sensory-predictive processes, and administered questionnaires to assess schizotypy and delusion-like thinking. Individuals with higher levels of delusional ideation showed more accurate force matching suggesting that such thinking is associated with a reduced tendency to predict and attenuate the sensory consequences of self-generated actions. These results suggest that deficits in sensory prediction in schizophrenia are not simply consequences of the deluded state and are not related to neuroleptic medication. Rather they appear to be stable, trait-like characteristics of an individual, a finding that has important implications for our understanding of the neurocognitive basis of delusions.
Resumo:
We investigate the transient ventilation flow within a confined ventilated space, with high- and low-level openings, when the strength of a low-level point source of heat is changed instantaneously. The steady-flow regime in the space involves a turbulent buoyant plume, which rises from the point source to a well-mixed warm upper layer. The steady-state height of the interface between this layer and the lower layer of exterior fluid is independent of the heat flux, but the upper layer becomes progressively warmer with heat flux. New analogue laboratory experiments of the transient adjustment between steady states identify that if the heat flux is increased, the continuing plume propagates to the top of the room forming a new, warmer layer. This layer gradually deepens, and as the turbulent plume entrains fluid from the original warm layer, the original layer is gradually depleted and disappears, and a new steady state is established. In contrast, if the source buoyancy flux is decreased, the continuing plume is cooler than the original plume, so that on reaching the interface it is of intermediate density between the original warm layer and the external fluid. The plume supplies a new intermediate layer, which gradually deepens with the continuing flow. In turn, the original upper layer becomes depleted, both as a result of being vented through the upper opening of the space, but also due to some penetrative entrainment of this layer by the plume, as the plume overshoots the interface before falling back to supply the new intermediate layer. We develop quantitative models which are in good accord with our experimental data, by combining classical plume theory with models of the penetrative entrainment for the case of a decrease in heating. Typically, we find that the effect of penetrative entrainment on the density of the intruding layer is relatively weak, provided the change in source strength is sufficiently large. However, penetrative entrainment measurably increases the rate at which the depth of the draining layer decreases. We conclude with a discussion of the importance of these results for the control of naturally ventilated spaces.
Resumo:
We report on an experimental and theoretical study of the transient flows which develop as a naturally ventilated room adjusts from one temperature to another. We focus on a room heated from below by a uniform heat source, with both high- and low-level ventilation openings. Depending on the initial temperature of the room relative to (i) the final equilibrium temperature and (ii) the exterior temperature, three different modes of ventilation may develop. First, if the room temperature lies between the exterior and the equilibrium temperature, the interior remains well-mixed and gradually heats up to the equilibrium temperature. Secondly, if the room is initially warmer than the equilibrium temperature, then a thermal stratification develops in which the upper layer of originally hot air is displaced upwards by a lower layer of relatively cool inflowing air. At the interface, some mixing occurs owing to the effects of penetrative convection. Thirdly, if the room is initially cooler than the exterior, then on opening the vents, the original air is displaced downwards and a layer of ambient air deepens from above. As this lower layer drains, it is eventually heated to the ambient temperature, and is then able to mix into the overlying layer of external air, and the room becomes well-mixed. For each case, we present new laboratory experiments and compare these with some new quantitative models of the transient flows. We conclude by considering the implications of our work for natural ventilation of large auditoria.
Resumo:
This paper describes two applications in speech recognition of the use of stochastic context-free grammars (SCFGs) trained automatically via the Inside-Outside Algorithm. First, SCFGs are used to model VQ encoded speech for isolated word recognition and are compared directly to HMMs used for the same task. It is shown that SCFGs can model this low-level VQ data accurately and that a regular grammar based pre-training algorithm is effective both for reducing training time and obtaining robust solutions. Second, an SCFG is inferred from a transcription of the speech used to train a phoneme-based recognizer in an attempt to model phonotactic constraints. When used as a language model, this SCFG gives improved performance over a comparable regular grammar or bigram. © 1991.
Resumo:
This talk describes a new version of the Multivariable Frequency Domain Toolbox for Matlab. The intellectual issue which arises here is whether there is a role for Matlab-4 GUI facilities in a Toolbox which provides relatively low-level functionality, with a correspondingly random pattern of user interaction. My belief is that there is a role, but it is very restricted: in effect only for providing convenient 'viewing' facilities for low-level objects (which are multivariable frequency responses in the case of the MFD Toolbox). There is a more obvious role for a GUI with higher-level functions, such as frequency domain identification or parametric controller optimisation.
Resumo:
The effect of an opposing wind on the stratification and flow produced by a buoyant plume rising from a heat source on the floor of a ventilated enclosure is investigated. Ventilation openings located at high level on the windward side of the enclosure and at low level on the leeward side allow a wind-driven flow from high to low level, opposite to the buoyancy-driven flow. One of two stable steady flow regimes is established depending on a dimensionless parameter F that characterizes the relative magnitudes of the wind-driven and buoyancy-driven velocities within the enclosure, and on the time history of the flow. A third, unstable steady flow solution is identified. For small opposing winds (small F) a steady, two-layer stratification and displacement ventilation is established. Exterior fluid enters through the lower leeward openings and buoyant interior fluid leaves through the upper windward openings. As the wind speed increases, the opposing wind may cause a reversal in the flow direction. In this case, cool exterior fluid enters through the high windward openings and mixes the interior fluid, which exits through the leeward openings. There are now two possibilities. If the rate of heat input by the source exceeds the rate of heat loss through the leeward openings, the temperature of the interior increases and this flow reversal is only maintained temporarily. The buoyancy force increases with time, the flow reverts to its original direction, and steady two-layer displacement ventilation is re-established and maintained. In this regime, the increase in wind speed increases the depth and temperature of the warm upper layer, and reduces the ventilation flow rate. If, on the other hand, the heat loss exceeds the heat input, the interior cools and the buoyancy-driven flow decreases. The reversed flow is maintained, the stratification is destroyed and mixing ventilation occurs. Further increases in wind speed increase the ventilation rate and decrease the interior temperature. The transitions between the two ventilation flow patterns exhibit hysteresis. The change from displacement ventilation to mixing ventilation occurs at a higher F than the transition from mixing to displacement. Further, we find that the transition from mixing to displacement ventilation occurs at a fixed value of F, whereas the transition from displacement to mixing flow is dependent on the details of the time history of the flow and the geometry of the openings, and is not determined solely by the value of F. Theoretical models that predic t the steady stratification profiles and flow rates for the displacement and mixing ventilation, and the transitions between them, are presented and compared with measurements from laboratory experiments. The transition between these ventilation patterns completely changes the internal environment, and we discuss some of the implications for the natural ventilation of buildings. © 2004 Cambridge University Press.
Resumo:
Vision based tracking can provide the spatial location of project related entities such as equipment, workers, and materials in a large-scale congested construction site. It tracks entities in a video stream by inferring their motion. To initiate the process, it is required to determine the pixel areas of the entities to be tracked in the following consecutive video frames. For the purpose of fully automating the process, this paper presents an automated way of initializing trackers using Semantic Texton Forests (STFs) method. STFs method performs simultaneously the segmentation of the image and the classification of the segments based on the low-level semantic information and the context information. In this paper, STFs method is tested in the case of wheel loaders recognition. In the experiments, wheel loaders are further divided into several parts such as wheels and body parts to help learn the context information. The results show 79% accuracy of recognizing the pixel areas of the wheel loader. These results signify that STFs method has the potential to automate the initialization process of vision based tracking.
Resumo:
Carbon nanotube (CNT) based nano electromechanical system (NEMS) were developed to apply to the logic and the memory circuit. The electrical 'on-off' behavior induced by the mechanical movements of CNTs can promise low power consumption in circuit with very low level leakage current. Additionally, the unique vertical structure of nanotubes allows high integration density for devices. © 2012 IEEE.