This paper describes the effect of the state of the inlet boundary layer (laminar or turbulent) on the structure of the endwall flow on two different profiles of low-pressure (LP) turbine blades (solid thin and hollow thick). At present the state of the endwall boundary layer at the inlet of a real LP turbine is not known. The intention of this paper is to show that, for different designs of LP turbine, the state of the inlet boundary layer affects the performance of the blade in very different ways. The testing was completed at low speed in a linear cascade using area traversing, flow visualization and static pressure measurements. The paper shows that, for a laminar inlet boundary layer, the two profiles have a similar loss distribution and structure of endwall flow. However, for a turbulent inlet boundary layer the two profiles are shown to differ significantly in both the total loss and endwall flow structure. The pressure side separation bubble on the solid thin profile is shown to interact with the passage vortex, causing a higher endwall loss than that measured on the hollow thick profile.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Distributed hybrid testing is a natural extension to and builds upon the local hybrid testing technique. Taking advantage of the hybrid nature of the test, it allows a sharing of resources and expertise between researchers from different disciplines by connecting multiple geographically distributed sites for joint testing. As part of the UK-NEES project, a successful series of three-site distributed hybrid tests have been carried out between Bristol, Cambridge and Oxford Universities. The first known multi-site distributed hybrid tests in the UK, they connected via a dedicated fibre network, using custom software, the geotechnical centrifuge at Cambridge to structural components at Bristol and Oxford. These experiments were to prove the connection and useful insights were gained into the issues involved with this distributed environment. A wider aim is towards providing a flexible testing framework to facilitate multi-disciplinary experiments such as the accurate investigation of the influence of foundations on structural systems under seismic and other loading. Time scaling incompatibilities mean true seismic soil structure interaction using a centrifuge at g is not possible, though it is clear that distributed centrifuge testing can be valuable in other problems. Development is continuing to overcome the issues encountered, in order to improve future distributed tests in the UK and beyond.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tunnelling in urban areas continues to increase and has highlighted the need for a better understanding of the impact of tunnel excavations on existing buildings. This paper considers the influence of surface structures on ground displacements caused by tunnelling in sand through finite element modelling and centrifuge testing. First, the importance of modelling assumptions is evaluated by comparing centrifuge modelling results to finite element modelling results for various soil constitutive models: both a Young's modulus that linearly increases with depth and a power law relation between the soil stiffness and stresses are considered. Second, the most effective soil constitutive model was used to perform a sensitivity study on the effect of different factors governing the structural response. In particular, the effect of the building stiffness and weight on the modification of soil displacements is investigated by introducing a simple surface structure. The use of a no-tension interface between the building and the soil was found to be essential to investigate the effect of weight on gap formation between the soil and the structure, as observed during the experimental tests. Results show the importance of considering the relation between the building weight and the relative stiffness between the building and the soil when assessing the structural response. © 2014 Korean Geotechnical Society.