6 resultados para Hot-water heating

em Cambridge University Engineering Department Publications Database


Relevância:

80.00% 80.00%

Publicador:

Resumo:

If a product is being designed to be genuinely inclusive, then the designers need to be able to assess the level of exclusion of the product that they are working on and to identify possible areas of improvement. To be of practical use, the assessments need to be quick, consistent and repeatable. The aim of this workshop is to invite attendees to participate in the evaluation of a number of everyday objects using an assessment technique being considered by the workshop organisers. The objectives of the workshop include evaluating the effectiveness of the assessment method, evaluating the accessibility of the products being assessed and to suggest revisions to the assessment scales being used. The assessment technique is to be based on the ONS capability measures [1]. This source recognises fourteen capability scales of which seven are particularly pertinent to product evaluation, namely: motion, dexterity, reach and stretch, vision, hearing, communication, and intellectual functioning. Each of these scales ranges from 0 (fully able) through 1 (minimal impairment) to 10 (severe impairment). The attendees will be asked to rate the products on these scales. Clearly the assessed accessibility of the product depends on the assumptions made about the context of use. The attendees will be asked to clearly note the assumptions that they are making about the context in which the product is being assessed. For instance, with a hot water bottle, assumptions have to be made about the availability of hot water and these can affect the overall accessibility rating. The workshop organisers will not specify the context of use as the aim is to identify how assessors would use the assessment method in the real world. The objects being assessed will include items such as remote controls, pill bottles, food packaging, hot water bottles and mobile telephones. the attendees will be encouraged to assess two or more products in detail. Helpers will be on hand to assist and observe the assessments. The assessments will be collated and compared and feedback about the assessment method sought from the attendees. Drawing on a preliminary review of the assessment results, initial conclusions will be presented at the end of the workshop. More detailed analyses will be made available in subsequent proceedings. It is intended that the workshop will provide workshop attendees with an opportunity to perform hands-on assessment of a number everyday products and identify features which are inclusive and those that are not. It is also intended to encourage an appreciation of the capabilities to be considered when evaluating accessibility.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Shortly after the loading of a pressurized water reactor (PWR) core, the axial power distribution in fresh fuel has already attained the characteristic, almost flat shape, typical of burned fuel. At beginning of cycle (BOC), however, the axial distribution is centrally peaked. In assemblies hosting uniform burnable boron rods, this BOC peaking is even more pronounced. A reduction in the axial peaking is today often achieved by shortening the burnable boron rods by some 30 cm at each edge. It is shown that a two-zone grading of the boron rod leads, in a representative PWR cycle, to a reduction of the hot-spot temperature of approximately 70 °C, compared with the nongraded case. However, with a proper three-zone grading of the boron rod, an additional 20 °C may be cut off the hot-spot temperature. Further, with a slightly skewed application of this three-zone grading, an additional 50 °C may be cut off. The representative PWR cycle studied was cycle 11 of the Indian Point 2 station, with a simplification in the number of fuel types and in the burnup distribution. The analysis was based on a complete three-dimensional burnup calculation. The code system was ELCOS, with BOXER as an assembly code for the generation of burnup-dependent cross sections and SILWER as a three-dimensional core code with thermal-hydraulic feedback.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The natural ventilation of a well-mixed, pre-heated room with a point source of heating, and openings at the base and roof is investigated. The transient draining associated with the room being warmer than the exterior combined with the convective ow produced by the point source of heat leads to a fascinating series of transient ow regimes as the system evolves to the two-layer steady-state regime described by Linden, Lane-Ser_ and Smeed [1]. As the room begins to ventilate, a turbulent plume rises from the point source of heat to the ceiling, and typically forms a deepening layer of hot air. However, with a weak heat source, then at some point the ascending plume will intrude beneath the layer of original uid. Otherwise, the ascending plume always reaches the top of the room as the system evolves to a steady state. We develop a simpli_ed model of the transient evolution and test this with some new laboratory experiments. We conclude with a discussion of the implications of our results for real buildings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In recent years, the presence of crusts within near surface sediments found in deep water locations off the west coast of Angola has been of interest to hot-oil pipeline designers. The origin for these crusts is considered to be of biological origin, based on the observation of thousands of faecal pellets in natural crust core samples. This paper presents the results of laboratory tests undertaken on natural and faecal pellet-only samples. These tests investigate the role faecal pellets play in modifying the gemechanical behaviour of clayey sediments. It is found that faecal pellets are able to significantly alter both the strength and the average grain-size of natural sediments, and therefore, influence the permeability and stiffness. Hot-oil pipelines self-embed into and subsequent shear on crusts containing faecal pellets. Being able to predict the time required for installed pipelines to consolidate the underlying sediment and thus, how soon after pipe-laying, the interface strength will develop is of great interest to pipeline designers. It is concluded from wet-sieving samples before and after oedometer tests, that the process of pipe laying is unlikely to destroy pellets. They will therefore, be a major constituent of the sediment subject to soil-pipeline shearing behaviour during axial pipe-walking and lateral buckling. Based on the presented results, a discussion highlighting the key implications for pipeline design is therefore provided. Copyright © 2011 by ASME.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have investigated the dynamics of hot charge carriers in InP nanowire ensembles containing a range of densities of zinc-blende inclusions along the otherwise wurtzite nanowires. From time-dependent photoluminescence spectra, we extract the temperature of the charge carriers as a function of time after nonresonant excitation. We find that charge-carrier temperature initially decreases rapidly with time in accordance with efficient heat transfer to lattice vibrations. However, cooling rates are subsequently slowed and are significantly lower for nanowires containing a higher density of stacking faults. We conclude that the transfer of charges across the type II interface is followed by release of additional energy to the lattice, which raises the phonon bath temperature above equilibrium and impedes the carrier cooling occurring through interaction with such phonons. These results demonstrate that type II heterointerfaces in semiconductor nanowires can sustain a hot charge-carrier distribution over an extended time period. In photovoltaic applications, such heterointerfaces may hence both reduce recombination rates and limit energy losses by allowing hot-carrier harvesting.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The capability of extending body structures is one of the most significant challenges in the robotics research and it has been partially explored in self-reconfigurable robotics. By using such a capability, a robot is able to adaptively change its structure from, for example, a wheel like body shape to a legged one to deal with complexity in the environment. Despite their expectations, the existing mechanisms for extending body structures are still highly complex and the flexibility in self-reconfiguration is still very limited. In order to account for the problems, this paper investigates a novel approach to robotic body extension by employing an unconventional material called Hot Melt Adhesives (HMAs). Because of its thermo-plastic and thermo-adhesive characteristics, this material can be used for additive fabrication based on a simple robotic manipulator while the established structures can be integrated into the robot's own body to accomplish a task which could not have been achieved otherwise. This paper first investigates the HMA material properties and its handling techniques, then evaluates performances of the proposed robotic body extension approach through a case study of a "water scooping" task. © 2012 IEEE.