4 resultados para GESTATIONAL-AGE
em Cambridge University Engineering Department Publications Database
Resumo:
INTRODUCTION: Recent studies in other European countries suggest that the prevalence of congenital cryptorchidism continues to increase. This study aimed to explore the prevalence and natural history of congenital cryptorchidism in a UK centre. METHODS: Between October 2001 and July 2008, 784 male infants were born in the prospective Cambridge Baby Growth Study. 742 infants were examined by trained research nurses at birth; testicular position was assessed using standard techniques. Follow-up assessments were completed at ages 3, 12, 18 and 24 months in 615, 462, 393 and 326 infants, respectively. RESULTS: The prevalence of cryptorchidism at birth was 5.9% (95% CI 4.4% to 7.9%). Congenital cryptorchidism was associated with earlier gestational age (p<0.001), lower birth weight (p<0.001), birth length (p<0.001) and shorter penile length at birth (p<0.0001) compared with other infants, but normal size after age 3 months. The prevalence of cryptorchidism declined to 2.4% at 3 months, but unexpectedly rose again to 6.7% at 12 months as a result of new cases. The cumulative incidence of "acquired cryptorchidism" by age 24 months was 7.0% and these cases had shorter penile length during infancy than other infants (p = 0.003). CONCLUSIONS: The prevalence of congenital cryptorchidism was higher than earlier estimates in UK populations. Furthermore, this study for the first time describes acquired cryptorchidism or "ascending testis" as a common entity in male infants, which is possibly associated with reduced early postnatal androgen activity.
Resumo:
OBJECTIVE: To examine the role of androgens on birth weight in genetic models of altered androgen signalling. SETTING: Cambridge Disorders of Sex Development (DSD) database and the Swedish national screening programme for congenital adrenal hyperplasia (CAH). PATIENTS: (1) 29 girls with XY karyotype and mutation positive complete androgen insensitivity syndrome (CAIS); (2) 43 girls and 30 boys with genotype confirmed CAH. MAIN OUTCOME MEASURES: Birth weight, birth weight-for-gestational-age (birth weight standard deviation score (SDS)) calculated by comparison with national references. RESULTS: Mean birth weight SDS in CAIS XY infants was higher than the reference for girls (mean, 95% CI: 0.4, 0.1 to 0.7; p=0.02) and was similar to the national reference for boys (0.1, -0.2 to 0.4). Birth weight SDS in CAH girls was similar to the national reference for girls (0.0, -0.2 to 0.2) and did not vary by severity of gene mutation. Birth weight SDS in CAH boys was also similar to the national reference for boys (0.2, -0.2 to 0.6). CONCLUSION: CAIS XY infants have a birth weight distribution similar to normal male infants and birth weight is not increased in infants with CAH. Alterations in androgen signalling have little impact on birth weight. Sex dimorphism in birth size is unrelated to prenatal androgen exposure.
Resumo:
In this paper we compare Multi-Layer Perceptrons (a neural network type) with Multivariate Linear Regression in predicting birthweight from nine perinatal variables which are thought to be related. Results show, that seven of the nine variables, i.e., gestational age, mother's body-mass index (BMI), sex of the baby, mother's height, smoking, parity and gravidity, are related to birthweight. We found no significant relationship between birthweight and each of the two variables, i.e., maternal age and social class.
Resumo:
OBJECTIVE: This work is concerned with the creation of three-dimensional (3D) extended-field-of-view ultrasound from a set of volumes acquired using a mechanically swept 3D probe. 3D volumes of ultrasound data can be registered by attaching a position sensor to the probe; this can be an inconvenience in a clinical setting. A position sensor can also cause some misalignment due to patient movement and respiratory motion. We propose a combination of three-degrees-of-freedom image registration and an unobtrusively integrated inertial sensor for measuring orientation. The aim of this research is to produce a reliable and portable ultrasound system that is able to register 3D volumes quickly, making it suitable for clinical use. METHOD: As part of a feasibility study we recruited 28 pregnant females attending for routine obstetric scans to undergo 3D extended-field-of-view ultrasound. A total of 49 data sets were recorded. Each registered data set was assessed for correct alignment of each volume by two independent observers. RESULTS: In 77-83% of the data sets more than four consecutive volumes registered. The successful registration relies on good overlap between volumes and is adversely affected by advancing gestational age and foetal movement. CONCLUSION: The development of reliable 3D extended-field-of-view ultrasound may help ultrasound practitioners to demonstrate the anatomical relation of pathology and provide a convenient way to store data.