19 resultados para Fluorescent lamps.

em Cambridge University Engineering Department Publications Database


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Compact Fluorescent Lamps (CFL) incorporating electronic ballasts are widely used in lighting. In many cases the ability to dim the lamp is a requirement Dimming can be achieved by varying the voltage supplied to the inverter or by changing the switching frequency of the inverter. The effect of dimming by both approaches on the power losses in the inverter is studied in this work. The lamp and associated inverter has been modeled in PSPICE, using a behavioral model for the CFL. Predicted losses are in good agreement with experimental data obtained from calorimetry. The model was then used to determine the distribution of losses within the inverter, enabling a comparison of the effects of the two dimming methods to be made. © 2006 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study an inductor-less piezoelectric transformer (PT) based ballast for a 5 W CFL has been designed and simulated. The predictions of circuit currents and losses closely match experimentally measured values. The total simulated loss figure was confirmed against practically determined losses using a precision mini-calorimeter. Using simulation to disaggregate the total loss figure, it is seen that the PT makes the largest contribution to the total losses in such ballast.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Commercially available integrated compact fluorescent lamps (CFLs) use self-resonant ballasts on grounds of simplicity and cost. To understand how to improve ballast efficiency, it is necessary to quantify the losses. The losses occurring in these ballasts have been directly measured using a precision mini-calorimeter. In addition, a Pspice model has been used to simulate the performance of an 18 W integrated CFL. The lamp has been represented by a behavioural model and Jiles-Atherton equations were used to model the current transformer core. The total loss is in close agreement with measurements from the mini-calorimeter, confirming the accuracy of the model. The total loss was then disaggregated into component losses by simulation, showing that the output inductor is the primary source of loss, followed by the inverter switches. © 2011 The Institution of Engineering and Technology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Compact fluorescent lamps (CFLs) incorporating electronic ballasts are widely used in lighting. In many cases, the ability to dim the lamp is a requirement. Dimming can be achieved by varying the switching frequency of the inverter or by changing the voltage supplied to the inverter. The effect of dimming by both approaches on the power losses in the inverter is studied in this work. The lamp and associated inverter has been modeled in Pspice, using a behavioral model for the CFL. Predicted losses are in good agreement with experimental data obtained from calorimetry. After verification, the model was then used to determine the distribution of losses within the inverter, enabling a comparison of the effects of the two dimming methods to be made. © 2011 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a study on a series of dye guest-host mixtures using fluorescent perylene-based molecules as the guest dye in an organosiloxane host. These hosts have temperature-independent switching, at room temperature, through 90° for fields of the order of 10 Vrms/μm. Perylene molecules have been grafted onto the organosiloxane moiety via an alkyl spacer producing novel and rugged fluorescent dyes that are readily miscible in the host. Micro-separation of the low molar mass siloxane groups in the mesophases tend to form smectic phases. These planes produce an effective two-dimensional polymer backbonethat engenders the rugged mechanical properties of polymeric liquid crystals onto these low molar mass ferroelectric liquid crystals. In this study we show how the introduction of the dye molecules affects the electro-optic properties of the organosiloxane host. © 2001 OPA (Overseas Publishers Association) N.V. Published by license under the Gordon and Breach Science Publishers imprint, a member of the Taylor & Francis Group,.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A custom designed microelectromechanical systems (MEMS) micro-hotplate, capable of operating at high temperatures (up to 700 C), was used to thermo-optically characterize fluorescent temperature-sensitive nanosensors. The nanosensors, 550 nm in diameter, are composed of temperature-sensitive rhodamine B (RhB) fluorophore which was conjugated to an inert silica sol-gel matrix. Temperature-sensitive nanosensors were dispersed and dried across the surface of the MEMS micro-hotplate, which was mounted in the slide holder of a fluorescence confocal microscope. Through electrical control of the MEMS micro-hotplate, temperature induced changes in fluorescence intensity of the nanosensors was measured over a wide temperature range. The fluorescence response of all nanosensors dispersed across the surface of the MEMS device was found to decrease in an exponential manner by 94%, when the temperature was increased from 25 C to 145 C. The fluorescence response of all dispersed nanosensors across the whole surface of the MEMS device and individual nanosensors, using line profile analysis, were not statistically different (p < 0.05). The MEMS device used for this study could prove to be a reliable, low cost, low power and high temperature micro-hotplate for the thermo-optical characterisation of sub-micron sized particles. The temperature-sensitive nanosensors could find potential application in the measurement of temperature in biological and micro-electrical systems. The Authors. © 2013 Published by Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, we present the analysis of electroosmotic flow in a branched -turn nanofluidic device, which we developed for detection and sorting of single molecules. The device, where the channel depth is only 150 nm, is designed to optically detect fluorescence from a volume as small as 270 attolitres (al) with a common wide-field fluorescent setup. We use distilled water as the liquid, in which we dilute 110 nm fluorescent beads employed as tracer-particles. Quantitative imaging is used to characterize the pathlines and velocity distribution of the electroosmotic flow in the device. Due to the device's complex geometry, the electroosmotic flow cannot be solved analytically. Therefore we use numerical flow simulation to model our device. Our results show that the deviation between measured and simulated data can be explained by the measured Brownian motion of the tracer-particles, which was not incorporated in the simulation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is a clear and increasing interest in short time annealing processing far below one second, i.e. the lower limit of Rapid Thermal Processing (RTP) called spike annealing. This was driven by the need of suppressing the so-called Transient Enhanced Diffusion in advanced boronimplanted shallow pn-junctions in silicon technology. Meanwhile the interest in flash lamp annealing (FLA) in the millisecond range spread out into other fields related to silicon technology and beyond. This paper reports on recent experiments regarding shallow junction engineering in germanium, annealing of ITO layers on glass and plastic foil to form an conductive layer as well as investigations which we did during the last years in the field of wide band gap semiconductor materials (SiC, ZnO). A more common feature evolving from our work was related to the modeling of wafer stress during millisecond thermal processing with flash lamps. Finally recent achievements in the field of silicon-based light emission basing on Metal-Oxide-Semiconductor Light Emitting Devices will be reported. © 2007 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The movement of the circular piston in an oscillating piston positive displacement flowmeter is important in understanding the operation of the flowmeter, and the leakage of liquid past the piston plays a key role in the performance of the meter. The clearances between the piston and the chamber are small, typically less than 60 νm. In order to measure this film thickness a fluorescent dye was added to the water passing through the meter, which was illuminated with UV light. Visible light images were captured with a digital camera and analysed to give a measure of the film thickness with an uncertainty of less than 7%. It is known that this method lacks precision unless careful calibration is undertaken. Methods to achieve this are discussed in the paper. The grey level values for a range of film thicknesses were calibrated in situ with six dye concentrations to select the most appropriate one for the range of liquid film thickness. Data obtained for the oscillating piston flowmeter demonstrate the value of the fluorescence technique. The method is useful, inexpensive and straightforward and can be extended to other applications where measurement of liquid film thickness is required. © 2011 IOP Publishing Ltd.