4 resultados para Floral Marker

em Cambridge University Engineering Department Publications Database


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The nuclear RNA binding protein, FCA, promotes Arabidopsis reproductive development. FCA contains a WW protein interaction domain that is essential for FCA function. We have identified FY as a protein partner for this domain. FY belongs to a highly conserved group of eukaryotic proteins represented in Saccharomyces cerevisiae by the RNA 3' end-processing factor, Pfs2p. FY regulates RNA 3' end processing in Arabidopsis as evidenced through its role in FCA regulation. FCA expression is autoregulated through the use of different polyadenylation sites within the FCA pre-mRNA, and the FCA/FY interaction is required for efficient selection of the promoter-proximal polyadenylation site. The FCA/FY interaction is also required for the downregulation of the floral repressor FLC. We propose that FCA controls 3' end formation of specific transcripts and that in higher eukaryotes, proteins homologous to FY may have evolved as sites of association for regulators of RNA 3' end processing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Optical motion capture systems suffer from marker occlusions resulting in loss of useful information. This paper addresses the problem of real-time joint localisation of legged skeletons in the presence of such missing data. The data is assumed to be labelled 3d marker positions from a motion capture system. An integrated framework is presented which predicts the occluded marker positions using a Variable Turn Model within an Unscented Kalman filter. Inferred information from neighbouring markers is used as observation states; these constraints are efficient, simple, and real-time implementable. This work also takes advantage of the common case that missing markers are still visible to a single camera, by combining predictions with under-determined positions, resulting in more accurate predictions. An Inverse Kinematics technique is then applied ensuring that the bone lengths remain constant over time; the system can thereby maintain a continuous data-flow. The marker and Centre of Rotation (CoR) positions can be calculated with high accuracy even in cases where markers are occluded for a long period of time. Our methodology is tested against some of the most popular methods for marker prediction and the results confirm that our approach outperforms these methods in estimating both marker and CoR positions. © 2012 Springer-Verlag.