190 resultados para Concrete slabs.

em Cambridge University Engineering Department Publications Database


Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A series of tests on filigree slab joints was performed with the aim of assessing whether such joints can be reliably used in the construction of two-way spanning reinforced concrete slabs. The test results were compared with code requirements. Adequate joint performance is shown to be achievable when the joints are appropriately detailed. Further research is recommended for the formulation of a more generic understanding when the design parameters are varied from those studied in this work.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

An engineer assessing the load-carrying capacity of an existing reinforced concrete slab is likely to use elastic analysis to check the load at which the structure might be expected to fail in flexure or in shear. In practice, many reinforced concrete slabs are highly ductile in flexure, so an elastic analysis greatly underestimates the loads at which they fail in this mode. The use of conservative elastic analysis has led engineers to incorrectly condemn many slabs and therefore to specify unnecessary and wasteful flexural strengthening or replacement. The lower bound theorem is based on the same principles as the upper bound theorem used in yield line analysis, but any solution that rigorously satisfies the lower bound theorem is guaranteed to be a safe underestimate of the collapse load. Jackson presented a rigorous lower bound method that obtains very accurate results for complex real slabs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Material production, and associated carbon emissions, could be reduced by reusing products instead of landfilling or recycling them. Steel beams are well suited to reuse, but are difficult to reuse when connected compositely to concrete slabs using welded studs. A demountable connection would allow composite performance but also permit reuse of both components at end-of-life. Three composite beams, of 2 m, 10 m and 5 m length, are constructed using M20 bolts as demountable shear connectors. The beams are tested in three-, six- and four-point bending, respectively. The former two are loaded to service, unloaded, demounted and reassembled; all three are tested to failure. The results show that all three have higher strengths than predicted using Eurocode 4. The longer specimens have performance similar to previously published comparable welded-connector composite beam results. This suggests that demountable composite beams can be safely used and practically reused, thus reducing carbon emissions. © 2013 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador: