18 resultados para Blood--Examination

em Cambridge University Engineering Department Publications Database


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Osteogenesis imperfecta (OI or brittle bone disease) is a disorder of connective tissues caused by mutations in the collagen genes. We previously showed that intrauterine transplantation of human blood fetal stem/stromal cells in OI mice (oim) resulted in a significant reduction of bone fracture. This work examines the cellular mechanisms and mechanical bone modifications underlying these therapeutic effects, particularly examining the direct effects of donor collagen expression on bone material properties. In this study, we found an 84% reduction in femoral fractures in transplanted oim mice. Fetal blood stem/stromal cells engrafted in bones, differentiated into mature osteoblasts, expressed osteocalcin, and produced COL1a2 protein, which is absent in oim mice. The presence of normal collagen decreased hydroxyproline content in bones, altered the apatite crystal structure, increased the bone matrix stiffness, and reduced bone brittleness. In conclusion, expression of normal collagen from mature osteoblast of donor origin significantly decreased bone brittleness by improving the mechanical integrity of the bone at the molecular, tissue, and whole bone levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interest is growing around the application of lean techniques to new product introduction (NPI). Although a relatively emergent topic compared with the application of 'lean' within the factory, since 2000 there has been an exponential rise in the literature on this subject. However, much of this work focuses on describing and extolling the virtues of the 'Toyota approach' to design. Therefore, by way of a stock take for the UK, the present authors' research has set out to understand how well lean product design practices have been adopted by leading manufacturers. This has been achieved by carrying out in-depth case studies with three carefully selected manufacturers of complex engineered products. This paper describes these studies, the detailed results and subsequent findings, and concludes that both the awareness and adoption of practices is generally embryonic and far removed from the theory advocated in the literature. © IMechE 2007.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several elastoplastic soil models have been proposed over the years that are formulated in strain space rather than stress space due to certain analytical and computational advantages. One such model, BRICK (Simpson 1992), has been continuously utilized and developed for industrial applications within Arup Geotechnics for more than two decades. This paper aims to describe the advantages and difficulties associated with strain space modeling. In addition, it will show how recent advances in modeling the effects of stress history, stiffness anisotropy, strength anisotropy and time-dependence in conventional stress space models can be transferred to the BRICK model. © 2010 Taylor & Francis Group, London.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The purpose of this study is to examine a buyer's adoption of servitization and the associated implications for the relationships with its suppliers. Design/methodology/approach: The authors use the case study approach to examine the tripartite relationship between a manufacturing company and two of its two suppliers. The paper explores the perspectives of employees on multiple organisational levels, and collects evidence on both sides of a relationship. The authors use template analysis utilising Cannon and Perreault's relationship connectors framework to analyse the data. Findings: There are overarching implications of servitization adoption for buyer-supplier relationships. The implications are notable in all five relationship connectors. Parties expected more open exchange of information, operational linkages were strengthened and changes in the structural arrangements of relationships were witnessed. Legal contracts are complemented by relational norms. The authors also observed a departure away from a win-lose mentality and increased levels of supplier adaptation to support the buyer's provision of integrated solutions. Research limitations/implications: The findings are confined to this tripartite relationship and to an extent are context specific. Practical implications: The study unveils buyer-supplier relationships in a servitized context and provides managers with a better understanding of some of the potential implications that the adoption of a servitization strategy may have for managing buyer-supplier relationships. Originality/value: This is the first empirical study that explores the implications of servitization on buyer-supplier relationships. It advances the understanding of the implications that the adoption of servitization has on the manner in which two parties interrelate and conduct commercial exchange. © Emerald Group Publishing Limited.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The analysis of scientific data is integral to materials engineering and science. The correlation between measured variables is often quantified by estimating the coefficient of determination or the r2 value. This is the recognised procedure for determining linear relationships. The authors review the derivation of the r2 value and derive an associated quantity, termed the relative deviation (RD), which is the ratio of the root mean square of the deviations about the fitted line to the root mean square of the deviations about the y bar line expressed as a percentage. The relative deviation has an advantage over the coefficient of determination in that it has greater numerical sensitivity to changes in the spread of data about the fitted line, especially when the scatter is small. In addition, the relative deviation is able to define, in percentage terms, the reduction in scatter when different independent variables are correlated with a common dependent variable. Four case studies in the materials field (aggregate crushing value, Atterberg limits, permeability and creep of asphalt) from work carried out at the Queensland Main Roads Department are presented to show the use of the new parameter RD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports a perspective investigation of computational modelling of blood fluid in microchannel devices as a preparation for future research on fluid-structure interaction (FSI) in biofluid mechanics. The investigation is carried out through two aspects, respectively on physical behaviours of blood flow in microchannels and appropriate methodology for modelling. The physics of blood flow is targeted to the challenges for describing blood flow in microchannels, including rheology of blood fluid, suspension features of red blood cells (RBCs), laminar hydrodynamic influence and effect of surface roughness. The analysis shows that due to the hyperelastic property of RBC and its comparable dimension with microchannels, blood fluid shows complex behaviours of two phase flow. The trajectory and migration of RBCs require accurate description of RBC deformation and interaction with plasma. Following on a discussion of modelling approaches, i.e. Eulerian method and Lagrangian method, the main stream modelling methods for multiphase flow are reviewed and their suitability to blood flow is analysed. It is concluded that the key issue for blood flow modelling is how to describe the suspended blood cells, modelled by Lagrangian method, and couple them with the based flow, modelled by Eulerian method. The multiphase flow methods are thereby classified based on the number of points required for describing a particle, as follows: (i) single-point particle methods, (ii) mutli-point particle methods, (iii) functional particle methods, and (iv) fluid particle methods. While single-point particle methods concentrate on particle dynamic movement, multipoint and functional particle methods can take into account particle mechanics and thus offer more detailed information for individual particles. Fluid particle methods provide good compromise between two phases, but require additional information for particle mechanics. For furthermore detailed description, we suggest to investigate the possibility using two domain coupling method, in which particles and base flow are modelled by two separated solvers. It is expected that this paper could clarify relevant issues in numerical modelling of blood flow in microchannels and induce some considerations for modelling blood flow using multiphase flow methods. © 2012 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Beneficial effects on bone-implant bonding may accrue from ferromagnetic fiber networks on implants which can deform in vivo inducing controlled levels of mechanical strain directly in growing bone. This approach requires ferromagnetic fibers that can be implanted in vivo without stimulating undue inflammatory cell responses or cytotoxicity. This study examines the short-term in vitro responses, including attachment, viability, and inflammatory stimulation, of human peripheral blood monocytes to 444 ferritic stainless steel fiber networks. Two types of 444 networks, differing in fiber cross section and thus surface area, were considered alongside austenitic stainless steel fiber networks, made of 316L, a widely established implant material. Similar high percent seeding efficiencies were measured by CyQuant® on all fiber networks after 48 h of cell culture. Extensive cell attachment was confirmed by fluorescence and scanning electron microscopy, which showed round monocytes attached at various depths into the fiber networks. Medium concentrations of lactate dehydrogenase (LDH) and tumor necrosis factor alpha (TNF-α) were determined as indicators of viability and inflammatory responses, respectively. Percent LDH concentrations were similar for both 444 fiber networks at all time points, whereas significantly lower than those of 316L control networks at 24 h. All networks elicited low-level secretions of TNF-α, which were significantly lower than that of the positive control wells containing zymosan. Collectively, the results indicate that 444 networks produce comparable responses to medical implant grade 316L networks and are able to support human peripheral blood monocytes in short-term in vitro cultures without inducing significant inflammatory or cytotoxic effects.