12 resultados para 965

em Cambridge University Engineering Department Publications Database


Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We characterized the electrical conductance of well-structured multi-walled carbon nanotubes (MWCNTs) which had post-treated by a rapid vacuum arc thermal annealing process and structure defects in these nanotubes are removed. We found that the after rapid vacuum arc annealing, the conductivity of well-structured MWCNTs can be improved by an order of magnitude. We also investigated the conductivity of MWCNTs bundle by the variation of temperatures. These results show that the conductance of annealed defect-free MWCNTs is sensitive to temperature imply the phonon scatting dominated the electron conductions. Compare to the well-structured MWCNTs, the defect scattering dominated the electron conduction in the as-grown control sample which has large amount of structure defects. A detail measurement of electron conduction from an individual well-structured MWCNT shows that the conductivity increases with temperatures which imply such MWCNTs exhibited semiconductor properties. We also produced back-gated field-effect transistors using these MWCNTs. It shows that the well-structured MWCNT can act as p-type semiconductor. © 2010 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is growing evidence that focal thinning of cortical bone in the proximal femur may predispose a hip to fracture. Detecting such defects in clinical CT is challenging, since cortices may be significantly thinner than the imaging system's point spread function. We recently proposed a model-fitting technique to measure sub-millimetre cortices, an ill-posed problem which was regularized by assuming a specific, fixed value for the cortical density. In this paper, we develop the work further by proposing and evaluating a more rigorous method for estimating the constant cortical density, and extend the paradigm to encompass the mapping of cortical mass (mineral mg/cm(2)) in addition to thickness. Density, thickness and mass estimates are evaluated on sixteen cadaveric femurs, with high resolution measurements from a micro-CT scanner providing the gold standard. The results demonstrate robust, accurate measurement of peak cortical density and cortical mass. Cortical thickness errors are confined to regions of thin cortex and are bounded by the extent to which the local density deviates from the peak, averaging 20% for 0.5mm cortex.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is growing evidence that focal thinning of cortical bone in the proximal femur may predispose a hip to fracture. Detecting such defects in clinical CT is challenging, since cortices may be significantly thinner than the imaging system's point spread function. We recently proposed a model-fitting technique to measure sub-millimetre cortices, an ill-posed problem which was regularized by assuming a specific, fixed value for the cortical density. In this paper, we develop the work further by proposing and evaluating a more rigorous method for estimating the constant cortical density, and extend the paradigm to encompass the mapping of cortical mass (mineral mg/cm 2) in addition to thickness. Density, thickness and mass estimates are evaluated on sixteen cadaveric femurs, with high resolution measurements from a micro-CT scanner providing the gold standard. The results demonstrate robust, accurate measurement of peak cortical density and cortical mass. Cortical thickness errors are confined to regions of thin cortex and are bounded by the extent to which the local density deviates from the peak, averaging 20% for 0.5mm cortex. © 2012 Elsevier B.V.