8 resultados para 18F Labelling

em Cambridge University Engineering Department Publications Database


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Detecting receptor dimerisation and other forms of clustering on the cell surface depends on methods capable of determining protein-protein separations with high resolution in the ∼10-50 nm range. However, this distance range poses a significant challenge because it is too large for fluorescence resonance energy transfer and contains distances too small for all other techniques capable of high-resolution in cells. Here we have adapted the technique of fluorophore localisation imaging with photobleaching to measure inter-receptor separations in the cellular environment. Using the epidermal growth factor receptor, a key cancer target molecule, we demonstrate ∼10 nm resolution while continuously covering the range of ∼10-80 nm. By labelling the receptor on cells expressing low receptor numbers with a fluorescent antagonist we have found inter-receptor separations all the way up from 8 nm to 59 nm. Our data are consistent with epidermal growth factor receptors being able to form homo-polymers of at least 10 receptors in the absence of activating ligands. © 2013 Needham et al.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Energy performance labelling and certification have been introduced widely to address market failures affecting the uptake of energy efficient technologies, by providing a signal to support decision making during contracting processes. The UK has recently introduced the Energy Performance Certificate (EPC) as a signal of building energy performance. The aims of this article are: to evaluate how valid EPC's are signals of occupier satisfaction with office facilities; and to understand whether occupant attitudes towards environmental issues have affected commercial office rental values. This was achieved by surveying occupant satisfaction with their workplaces holistically using a novel multi-item rating scale which gathered 204 responses. Responses to this satisfaction scale were matched with the corresponding EPC and rental value of occupier's workplaces. The satisfaction scale was found to be both a reliable and valid measure. The analysis found that EPC asset rating correlates significantly with occupant satisfaction with all facility attributes. Therefore, EPC ratings may be considered valid signals of overall facility satisfaction within the survey sample. Rental value was found to correlate significantly only with facility aesthetics. No evidence suggests rental value has been affected by occupants' perceptions towards the environmental impact of facilities. © 2013 The Authors.