182 resultados para 090504 Earthquake Engineering

em Cambridge University Engineering Department Publications Database


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The Mw= 7.2 Haiti earthquake of 12th January 2010 caused extensive damage to buildings and other infrastructure in the epicentral region in and around Port-au-Prince. The Earthquake Engineering Field Investigation Team (EEFIT), which is based in the United Kingdom, organised a field mission to Haiti with the authors as the team members. The paper presents the geotechnical findings of the team including those relating to soil liquefaction and lateral spreading and discusses the performance of buildings, including historic buildings, and bridges. Unprecedented use was made of damage assessments made from remote images (i. e. images taken from satellites and aircraft) when planning the post-earthquake relief effort in Haiti and a principal objective of the team was to evaluate the accuracy of such assessments. Accordingly, 142 buildings in Port-au-Prince were inspected in the field by the EEFIT team; damage assessments had previously been made using remote images for all these buildings. On the basis of this survey, the tendency of remote assessments to underestimate damage was confirmed; it was found that the underestimate applied to assessments based on oblique images using the relatively new technique of Pictometry, as well as those based on vertical images, although to a lesser degree. The paper also discusses the distribution of damage in Port-au-Prince, which was found to be strongly clustered in ways that appear not to have been completely explained. © 2012 Springer Science+Business Media B.V.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Underground structures located in liquefiable soil deposits are susceptible to floatation following an earthquake event due to their lower unit weight relative to the surrounding saturated soil. This inherent buoyancy may cause lightweight structures to float when the soil liquefies. Centrifuge tests have been carried out to study the excess pore pressure generation and dissipation in liquefiable soils. In these tests, near full liquefaction conditions were attained within a few cycles of the earthquake loading. In the case of high hydraulic conductivity sands, significant dissipation could take place even during the earthquake loading which inhibits full liquefaction from occurring. In the case of excess pore pressure generation and dissipation around a floating structure, the cyclic response of the structure may lead to the reduction in excess pore pressure near the face of the structure as compared to the far field. This reduction in excess pore pressure is due to shear-induced dilation and suction pressures arising from extensile stresses at the soil-structure interface. Given the lower excess pore pressure around the structure; the soil around the structure retains a portion of this shear strength which in turn can discourage significant uplift of the underground structure. Copyright © 2012, IGI Global.