138 resultados para error monitoring


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a device which can be used to detect variation in the integrity of the surrounding medium which supports buried gas pipes. The method is also applicable to other kinds of pipe. Variation in pipe support condition leads to increased likelihood of pipe damage under vehicle loading. A vibrating 'pig' has been developed and tested on buried pipelines in Britain and the measured data obtained is compared with theoretical models. Certain features, such as voids, hard spots and joints, display characteristic responses to vibration and a library of such characteristics has been constructed both experimentally and from the theoretical models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reliability of the measuring devices is very important problem. Optical fibre sensors are very efficient. The use of optical fibre sensors for monitoring the physical and chemical parameters has been expanding over resent years. These sensors are applied for monitoring the structural integrity of long, parallel lay synthetic ropes. Such ropes are corrosion free, however, their operational lifetime under cyclic load is not well understood and premature failure can occur due to slippage and breakage of yarns within the rope. The monitoring system has been proposed which is based on acoustic detection of yarn breakage. Monitoring the strain and temperature is performed using the array of fibre gratings distributed along the rope length.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A wavelength conversion device was demonstrated at the bit rate of 2.488 Gb/s with 2R (reamplification and reshaping) regenerative properties. A low frequency pilot tone was removed during the conversion process and a new one added. The wavelength converter is shown to operate well at 10 Gb/s, and tone identification/replacement should also be possible at this data rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper describes the use of optical fiber Brillouin Optical Time Domain Reflectometry (BOTDR) to monitor the strain distribution in an existing tunnel while a twin tunnel was bored at close-proximity. The twin circular bored tunnels between Serangoon and Bartley stations on the new Circle Line Stage 3 subway in Singapore were constructed at close-proximity to avoid underpinning the foundations of adjacent buildings. The minimum clear separation of the two tunnels is 2.3m (0.4 times the tunnel diameter). The Outer Tunnel was constructed first, followed by the Inner Tunnel, with the earth-pressure balance tunnel boring machines maintained at a minimum of 100m apart. In this trial application of BOTDR, the strain distribution along the Outer Tunnel was measured, in order to monitor its deformation due to the boring of the Inner Tunnel at close-proximity. The aim of the trial application was to determine the practicality of this monitoring method for future use in 'live' tunnels. This paper compares the measurements obtained from optical fiber BOTDR with conventional methods of tunnel monitoring and describes preliminary installation and workmanship guidelines derived from lessons learnt during this trial. © 2007 ASCE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although a wide range of techniques exist for slope monitoring, the task of monitoring slopes is sometimes complicated by the extensive nature and unpredictability of slope movements. The Brillouin optical time-domain reflectometer (BOTDR) is a distributed optical fiber strain measurement technology utilising Brillouin scattering. This method measures continuous strain along a standard optical fibre over a distance up to 10 km and hence has potential to detect deformations and diagnose problems along large sections of slopes and embankments. This paper reports the demonstration of BOTDR method for monitoring surface ground movements of clay cuttings and embankments along London's ring M25 motorway. A field trial investigating varying methods of onsite fibre optic installations was conducted. The surrounding ground was artificially moved by excavating a 3 m deep trench perpendicular to the instrumented sections. Results obtained from onsite installations after slope movement demonstrate a half-pipe covered fibre optic installed on wide (200mm) Tensar ™SS20 geogrid gives the most consistent recorded strain change profile. Initial conclusions suggest this method best represents induced ground motion at the surface and hence is recommended for implementation in future sitework. Copyright ASCE 2008.