135 resultados para VOOS LOW COST


Relevância:

80.00% 80.00%

Publicador:

Resumo:

A custom designed microelectromechanical systems (MEMS) micro-hotplate, capable of operating at high temperatures (up to 700 C), was used to thermo-optically characterize fluorescent temperature-sensitive nanosensors. The nanosensors, 550 nm in diameter, are composed of temperature-sensitive rhodamine B (RhB) fluorophore which was conjugated to an inert silica sol-gel matrix. Temperature-sensitive nanosensors were dispersed and dried across the surface of the MEMS micro-hotplate, which was mounted in the slide holder of a fluorescence confocal microscope. Through electrical control of the MEMS micro-hotplate, temperature induced changes in fluorescence intensity of the nanosensors was measured over a wide temperature range. The fluorescence response of all nanosensors dispersed across the surface of the MEMS device was found to decrease in an exponential manner by 94%, when the temperature was increased from 25 C to 145 C. The fluorescence response of all dispersed nanosensors across the whole surface of the MEMS device and individual nanosensors, using line profile analysis, were not statistically different (p < 0.05). The MEMS device used for this study could prove to be a reliable, low cost, low power and high temperature micro-hotplate for the thermo-optical characterisation of sub-micron sized particles. The temperature-sensitive nanosensors could find potential application in the measurement of temperature in biological and micro-electrical systems. The Authors. © 2013 Published by Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

There is considerable demand for sensors that are capable of detecting ultra-low concentrations (sub-PPM) of toxic gases in air. Of particular interest are NO2 and CO that are exhaust products of internal combustion engines. Electrochemical (EC) sensors are widely used to detect these gases and offer the advantages of low power, good selectivity and temporal stability. However, EC sensors are large (1 cm3), hand-made and thus expensive ($25). Consequently, they are unsuitable for the low-cost automotive market that demands units for less than $10. One alternative technology is SnO2 or WO3 resistive gas sensors that are fabricated in volume today using screen-printed films on alumina substrates and operate at 400°C. Unfortunately, they suffer from several disadvantages: power consumption is high 200 mW; reproducibility of the sensing element is poor; and cross-sensitivity is high. © 2013 IEEE.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An innovative, simple, compact and low cost approach for phase mapping based on the intrinsic modulation of an aperture Near Field Scanning Optical Microscope probe is analyzed and experimentally demonstrated. Several nanoscale silicon waveguides are phase-mapped using this approach, and the different modes of propagation are obtained via Fourier analysis. The obtained measured results are in good agreement with the effective indexes of the modes calculated by electromagnetic simulations. Owing to its simplicity and effectiveness, the demonstrated system is a potential candidate for integration with current near field systems for the characterization of nanophotonic components and devices.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An innovative, simple, compact and low cost approach for phase mapping based on the intrinsic modulation of an aperture Near Field Scanning Optical Microscope probe is analyzed and experimentally demonstrated. Several nanoscale silicon waveguides are phase-mapped using this approach, and the different modes of propagation are obtained via Fourier analysis. The obtained measured results are in good agreement with the effective indexes of the modes calculated by electromagnetic simulations. Owing to its simplicity and effectiveness, the demonstrated system is a potential candidate for integration with current near field systems for the characterization of nanophotonic components and devices. © 2011 Optical Society of America.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Ten years ago the intelligent product model was introduced as a means of motivating a supply chain in which product or orders were central as opposed to the organizations that stored or delivered them. This notion of a physical product influencing its own movement through the supply chain was enabled by the evolution of low cost RFID systems which promised low cost connection between physical goods and networked information environments. In 2002 the notion of product intelligence was regarded as a useful but rather esoteric construct. However, in the intervening ten years there have been a number of technological advances coupled with an increasingly challenged business environment which make the prospects for intelligent product deployment seem more likely. This paper reviews a number of these developments and assesses their impact on the intelligent product approach. © Springer-Verlag Berlin Heidelberg 2013.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The paper presents the design and performance analysis of a 6 MW medium-speed Brushless Doubly-Fed Induction Generation (Brushless DFIG) for a wind turbine drivetrain. Two machines with different frame sizes have been designed to show the flexibility of the design procedure. The mediumspeed Brushless DFIG in combination with a two stage gearbox offers a low-cost, low-maintenance and reliable drivetrain for wind turbine applications.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We propose a new low-cost solution using orthogonal transmission of non-return-tozero and carrierless-amplitude-and-phase format data to realize a coarse OFDM transmission system. Using low bandwidth electronics and optoelectronic components, the system is demonstrated at 37.5Gb/s. © OSA/ CLEO 2011.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Healthcare systems worldwide face a wide range of challenges, including demographic change, rising drug and medical technology costs, and persistent and widening health inequalities both within and between countries. Simultaneously, issues such as professional silos, static medical curricula, and perceptions of "information overload" have made it difficult for medical training and continued professional development (CPD) to adapt to the changing needs of healthcare professionals in increasingly patient-centered, collaborative, and/or remote delivery contexts. In response to these challenges, increasing numbers of medical education and CPD programs have adopted e-learning approaches, which have been shown to provide flexible, low-cost, user-centered, and easily updated learning. The effectiveness of e-learning varies from context to context, however, and has also been shown to make considerable demands on users' motivation and "digital literacy" and on providing institutions. Consequently, there is a need to evaluate the effectiveness of e-learning in healthcare as part of ongoing quality improvement efforts. This article outlines the key issues for developing successful models for analyzing e-health learning.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An innovative, simple compact and low cost approach for phase mapping based on the intrinsic modulation of a Near Field Scanning Optical Microscope probe is analyzed and experimentally demonstrated. © OSA/ CLEO 2011.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A monolithic design is proposed for low-noise sub-THz signal generation by integrating a reflector onto a dual laser source. The reflectivity and the position of such a reflector can be adjusted to obtain constructive feedback from the reflector to both lasers, thus causing a Vernier feedback effect. As a result, 10-fold line narrowing, the narrowing being limited by the resolution of the simulation, is predicted using a transmission line model. Finally, a simple control scheme using an electrical feedback loop to adjust laser biases is proposed to maintain the line narrowing performance. This line narrowing technique, comprising a passive integrated reflector, could allow the development of a low-cost, compact and energy-efficient solution for high-purity sub-THz signal generation. © The Institution of Engineering and Technology 2014.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Optical technologies have received large interest in recent years for use in board-level interconnects. Polymer multimode waveguides in particular, constitute a promising technology for high-capacity optical backplanes as they can be cost-effectively integrated onto conventional printed circuit boards (PCBs). This paper presents the first optical backplane demonstrator based on the use of PCB-integrated polymer multimode waveguides and a regenerative shared bus architecture. The backplane demonstrator is formed with commercially-available low-cost electronic and photonic components onto conventional FR4 substrates and comprises two opto-electronic (OE) bus modules interconnected via a prototype regenerator unit. The system enables interconnection between the connected cards over four optical channels, each operating at 10 Gb/s. Bus extension is achieved by cascading OE bus modules via 3R regenerator units, overcoming therefore the inherent limitation of optical bus topologies in the maximum number of cards that can be connected to the bus. Details of the design, fabrication, and assembly of the different parts of this optical bus backplane are presented and related optical and data transmission characterisation studies are reported. The optical layer of the OE bus modules comprises a four-channel three-card waveguide layout that is compatible with VCSEL/PD arrays and ribbon fibres. All on-board optical paths exhibit insertion losses below 13 dB and intra-channel crosstalk lower than -29 dB. The robustness of the signal distribution from the bus inputs to all respective bus output ports in the presence of input misalignment is demonstrated, while 1 dB input alignment tolerances of approximately ±10 μm are obtained. The electrical layer of the OE bus modules comprises the essential driving circuitry for 1×4 VCSEL and PD arrays and the corresponding control and power regulation circuits. The interface between the optical and electrical layers of the bus modules is achieved with simple OE connectors that enable end-fired optical coupling into and out of the on-board polymer waveguides. The backplane demonstrator achieves error-free (BER < 10-12) 10 Gb/s data transmission over each optical channel, enabling therefore, an aggregate interconnection capacity of 40 Gb/s between any connected cards. © 1983-2012 IEEE.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Surface acoustic wave devices are extensively used in contemporary wireless communication devices. We used atomic force microscopy to form periodic macroscopic ferroelectric domains in sol-gel deposited lead zirconate titanate, where each ferroelectric domain is composed of many crystallites, each of which contains many microscopic ferroelastic domains. We examined the electro-acoustic characteristics of the apparatus and found a resonator behavior similar to that of an equivalent surface or bulk acoustic wave device. We show that the operational frequency of the device can be tailored by altering the periodicity of the engineered domains and demonstrate high-frequency filter behavior (>8GHz), allowing low-cost programmable high-frequency resonators. © 2014 AIP Publishing LLC.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Electronic systems are a very good platform for sensing biological signals for fast point-of-care diagnostics or threat detection. One of the solutions is the lab-on-a-chip integrated circuit (IC), which is low cost and high reliability, offering the possibility for label-free detection. In recent years, similar integrated biosensors based on the conventional complementary metal oxide semiconductor (CMOS) technology have been reported. However, post-fabrication processes are essential for all classes of CMOS biochips, requiring biocompatible electrode deposition and circuit encapsulation. In this work, we present an amorphous silicon (a-Si) thin film transistor (TFT) array based sensing approach, which greatly simplifies the fabrication procedures and even decreases the cost of the biosensor. The device contains several identical sensor pixels with amplifiers to boost the sensitivity. Ring oscillator and logic circuits are also integrated to achieve different measurement methodologies, including electro-analytical methods such as amperometric and cyclic voltammetric modes. The system also supports different operational modes. For example, depending on the required detection arrangement, a sample droplet could be placed on the sensing pads or the device could be immersed into the sample solution for real time in-situ measurement. The entire system is designed and fabricated using a low temperature TFT process that is compatible to plastic substrates. No additional processing is required prior to biological measurement. A Cr/Au double layer is used for the biological-electronic interface. The success of the TFT-based system used in this work will open new avenues for flexible label-free or low-cost disposable biosensors. © 2013 Materials Research Society.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Usually, firms that produce innovative global products are discussed within the context of developed countries. New ventures in developing countries are typically viewed as low-cost product providers that generate technologically similar products to those produced by developed economies. However, this paper argues that some Chinese university spin-outs (USOs), although rare, have adopted a novel 'catch-up' strategy to build global products on the basis of indigenous platform technologies. This paper attempts to develop a conceptual framework to address the question: how do these specific Chinese USOs develop their innovation capabilities to build global products? In order to explore the idiosyncrasies of the specific USOs, this paper uses the multiple case studies method. The primary data sources are accessed through semi-structured interviews. In addition, archival data and other materials are used as secondary sources. The study analyses the configuration of capabilities that are needed for idiosyncratic growth, and maps them to the globalisation processes. This paper provides a strategic 'roadmap' as an explanatory guide to entrepreneurs, policy makers and investors to better understand the phenomena. © 2014 Inderscience Enterprises Ltd.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study presents a novel approach to the design of low-cost and energy-efficient hopping robots, which makes use of free vibration of an elastic curved beam. We found that a hopping robot could benefit from an elastic curved beam in many ways such as low manufacturing cost, light body weight and small energy dissipation in mechanical interactions. A challenging problem of this design strategy, however, lies in harnessing the mechanical dynamics of free vibration in the elastic curved beam: because the free vibration is the outcome of coupled mechanical dynamics between actuation and mechanical structures, it is not trivial to systematically design mechanical structures and control architectures for stable locomotion. From this perspective, this paper investigates a case study of simple hopping robot to identify the design principles of mechanics and control. We developed a hopping robot consisting of an elastic curved beam and a small rotating mass, which was then modeled and analyzed in simulation. The experimental results show that the robot is capable of exhibiting stable hopping gait patterns by using a small actuation with no sensory feedback owing to the intrinsic stability of coupled mechanical dynamics. Furthermore, an additional analysis shows that, by exploiting free vibration of the elastic curved beam, cost of transport of the proposed hopping locomotion can be in the same rage of animals' locomotion including human running. © 2011 IEEE.