138 resultados para Fluorescent antibody technique
Resumo:
Compact Fluorescent Lamps (CFL) incorporating electronic ballasts are widely used in lighting. In many cases the ability to dim the lamp is a requirement Dimming can be achieved by varying the voltage supplied to the inverter or by changing the switching frequency of the inverter. The effect of dimming by both approaches on the power losses in the inverter is studied in this work. The lamp and associated inverter has been modeled in PSPICE, using a behavioral model for the CFL. Predicted losses are in good agreement with experimental data obtained from calorimetry. The model was then used to determine the distribution of losses within the inverter, enabling a comparison of the effects of the two dimming methods to be made. © 2006 IEEE.
Resumo:
In this study an inductor-less piezoelectric transformer (PT) based ballast for a 5 W CFL has been designed and simulated. The predictions of circuit currents and losses closely match experimentally measured values. The total simulated loss figure was confirmed against practically determined losses using a precision mini-calorimeter. Using simulation to disaggregate the total loss figure, it is seen that the PT makes the largest contribution to the total losses in such ballast.
Resumo:
A packaging technique suited to applying MEMS strain sensors realized on a silicon chip to a steel flat surface is described. The method is based on adhesive bonding of the silicon chip rear surface on steel using two types of glue normally used for standard piezoresistive strain sensors (Mbond200/ 600), using direct wire bonding of the chip to a Printed Circuit Board, also fixed on steel. In order to protect the sensor from the external environment, and to improve the MEMS performance, the silicon chip is encapsulated with a metal cap hermetically sealed-off under vacuum condition with a vacuum adhesive in which the bonding wires are also protected from possible damage. In order to evaluate the mechanical coupling of the silicon chip with the bar and thestress transfer extent to the silicon surface, commercial strain sensors have been applied on the chip glued on a steel bar in alaboratory setup able to generate strain by inflection, yielding a stress transfer around 70% from steel to silicon. © 2008 IEEE.
Resumo:
Here we present a novel signal processing technique for a square wave thermally-modulated carbon black/polymer composite chemoresistor. The technique consists of only two mathematical operations: summing the off-transient and on-transient conductance signals; and subtracting the steady-state conductance signal. A single carbon black/polyvinylpyrrolidone composite chemo -resistor was fabricated and used to demonstrate the validity of the technique. Classification of water, methanol and ethanol vapours was successfully performed using only the peak time of the resultant curves. Quantification of the different vapours was also possible using the height of the peaks, because it was linearly proportional to concentration. This technique does not require zero-gas calibration and thus is superior to previously reported methods. ©2009 IEEE.
Resumo:
Commercially available integrated compact fluorescent lamps (CFLs) use self-resonant ballasts on grounds of simplicity and cost. To understand how to improve ballast efficiency, it is necessary to quantify the losses. The losses occurring in these ballasts have been directly measured using a precision mini-calorimeter. In addition, a Pspice model has been used to simulate the performance of an 18 W integrated CFL. The lamp has been represented by a behavioural model and Jiles-Atherton equations were used to model the current transformer core. The total loss is in close agreement with measurements from the mini-calorimeter, confirming the accuracy of the model. The total loss was then disaggregated into component losses by simulation, showing that the output inductor is the primary source of loss, followed by the inverter switches. © 2011 The Institution of Engineering and Technology.
Resumo:
We present a study on a series of dye guest-host mixtures using fluorescent perylene-based molecules as the guest dye in an organosiloxane host. These hosts have temperature-independent switching, at room temperature, through 90° for fields of the order of 10 Vrms/μm. Perylene molecules have been grafted onto the organosiloxane moiety via an alkyl spacer producing novel and rugged fluorescent dyes that are readily miscible in the host. Micro-separation of the low molar mass siloxane groups in the mesophases tend to form smectic phases. These planes produce an effective two-dimensional polymer backbonethat engenders the rugged mechanical properties of polymeric liquid crystals onto these low molar mass ferroelectric liquid crystals. In this study we show how the introduction of the dye molecules affects the electro-optic properties of the organosiloxane host. © 2001 OPA (Overseas Publishers Association) N.V. Published by license under the Gordon and Breach Science Publishers imprint, a member of the Taylor & Francis Group,.
Resumo:
The adhesion of bovine chondrocytes and human osteoblasts to three titania-based coatings, formed by plasma electrolytic oxidation (PEO), was compared to that on uncoated Ti-6Al-4V substrates, and some comparisons were also made with plasma sprayed hydroxyapatite (HA) coatings. This was done using a centrifuge, with accelerations of up to 160,000 g, so as to induce buoyancy forces that created normal or shear stresses at the interface. It is shown that, on all surfaces, it was easier to remove cells under normal loading than under shear loading. Cell adhesion to the PEO coatings was stronger than that on Ti-6Al-4V and similar to that on HA. Cell proliferation rates were relatively high on one of the PEO coatings, which was virtually free of aluminium, but low on the other two, which contained significant levels of aluminium. It is concluded that the Al-free PEO coating offers promise for application to prosthetic implants.
Resumo:
The movement of the circular piston in an oscillating piston positive displacement flowmeter is important in understanding the operation of the flowmeter, and the leakage of liquid past the piston plays a key role in the performance of the meter. The clearances between the piston and the chamber are small, typically less than 60 νm. In order to measure this film thickness a fluorescent dye was added to the water passing through the meter, which was illuminated with UV light. Visible light images were captured with a digital camera and analysed to give a measure of the film thickness with an uncertainty of less than 7%. It is known that this method lacks precision unless careful calibration is undertaken. Methods to achieve this are discussed in the paper. The grey level values for a range of film thicknesses were calibrated in situ with six dye concentrations to select the most appropriate one for the range of liquid film thickness. Data obtained for the oscillating piston flowmeter demonstrate the value of the fluorescence technique. The method is useful, inexpensive and straightforward and can be extended to other applications where measurement of liquid film thickness is required. © 2011 IOP Publishing Ltd.
Resumo:
Software importance keeps growing fast and consistently for many organizations. The growth of software functionality in manufactured products and the emergence of digital media, convergent spaces including digital content, software, and multi-channels to the market, are recent examples of organizational changes where software assumed a central position for the corporate strategy. This paper analyzes the alignment between strategic objectives and software development processes at software companies and proposes a methodology to ensure that development processes are aligned with the corporate capabilities required to exploit future market opportunities. The methodology includes the categorization of different software companies according to their core capabilities and the customization of the technology roadmapping technique for software companies. The research process included the realization of case studies and a survey. (c) 2006 PICMET.