118 resultados para Electronics, Medical.
Resumo:
We demonstrate inkjet printing as a viable method for large-area fabrication of graphene devices. We produce a graphene-based ink by liquid phase exfoliation of graphite in N-methylpyrrolidone. We use it to print thin-film transistors, with mobilities up to ∼95 cm(2) V(-1) s(-1), as well as transparent and conductive patterns, with ∼80% transmittance and ∼30 kΩ/□ sheet resistance. This paves the way to all-printed, flexible, and transparent graphene devices on arbitrary substrates.
Resumo:
Thin-film electronics in its myriad forms has underpinned much of the technological innovation in the fields of displays, sensors, and energy conversion over the past four decades. This technology also forms the basis of flexible electronics. Here we review the current status of flexible electronics and attempt to predict the future promise of these pervading technologies in healthcare, environmental monitoring, displays and human-machine interactivity, energy conversion, management and storage, and communication and wireless networks. © 2012 IEEE.
Resumo:
We report on the photoresponse characteristics of tungsten disulfide (WS2) nanotubes. Field effect transistors (FETs) were fabricated by using individual WS2 multiwall nanotubes. Photo-sensitivity to visible light is clearly observed, with enhancement of the channel conductivity, carrier mobility and carrier concentration upon illumination in the visible regime. Polarization-sensitive measurements reveal a strong anisotropy of the photocurrent on the polarization angle of the incident light with respect to the WS2 nanotube axis. This nano-scale transistor capable of detecting visible light would have a wide range of applications in medical and consumer electronics. © 2008 IEEE. Crown Copyright.
Resumo:
Innovation is a critical factor in ensuring commercial success within the area of medical technology. Biotechnology and Healthcare developments require huge financial and resource investment, in-depth research and clinical trials. Consequently, these developments involve a complex multidisciplinary structure, which is inherently full of risks and uncertainty. In this context, early technology assessment and 'proof of concept' is often sporadic and unstructured. Existing methodologies for managing the feasibility stage of medical device development are predominantly suited to the later phases of development and favour detail in optimisation, validation and regulatory approval. During these early phases, feasibility studies are normally conducted to establish whether technology is potentially viable. However, it is not clear how this technology viability is currently measured. This paper aims to redress this gap through the development of a technology confidence scale, as appropriate explicitly to the feasibility phase of medical device design. These guidelines were developed from analysis of three recent innovation studies within the medical device industry.
Resumo:
In a hospital environment that demands a careful balance between commercial and clinical interests, the extent to which physicians are involved in hospital leadership varies greatly. This paper assesses the influence of the extent of this involvement on staff-to-patient ratios. Using data gathered from 604 hospitals across Germany, this study evidences the positive relationship between a full-time medical director (MD) or heavily involved part-time MD and a higher staff-to-patient ratio. The data allows us to control for a range of confounding variables, such as size, rural/urban location, ownership structure, and case-mix. The results contribute to the sparse body of empirical research on the effect of clinical leadership on organizational outcomes.
Resumo:
We report the use of near-field electrospinning (NFES) as a route to fabricate composite electrodes. Electrodes made of composite fibers of carbon nanotubes in polyethylene oxide (PEO) are formed via liquid deposition, with precise control over their configuration. The electromechanical properties of free-standing fibers and fibers deposited on elastic substrates are studied in detail. We then examine the elastic deformation limit of the resulting free-standing fibers and find, similarly to bulk PEO composites, that the plastic deformation onset is below 2% of tensile strain. In comparison, the apparent deformation limit is much improved when the fibers are integrated onto a stretchable, elastic substrate. It is hoped that the NFES fabrication protocol presented here can provide a platform to direct-write polymeric electrodes, and to integrate both stiff and soft electrodes onto a variety of polymeric substrates. © 2012 IEEE.
Resumo:
This review summarises the recent advances in the field of silicon nanowire electronics from bottom-up assembled materials. The aim is to draw a comparison between bottom-up and top-down approaches, examining respective achievements and evaluating advantages and disadvantages of each methodology. Existing techniques for synthesis and doping are discussed to provide the framework in which practical electronic applications can be developed. Next, key device categories are reviewed, emphasising current challenges and proposed solutions. Finally, field perspectives are outlined. © 2012 Elsevier Ltd.
Resumo:
Numerical methods based on the Reynolds Averaged Navier-Stokes (RANS) and Large Eddy Simulation (LES) equations are applied to the thermal prediction of flows representative of those found in and around electronics systems and components. Low Reynolds number flows through a heated ribbed channel, around a heated cube and within a complex electronics system case are investigated using linear and nonlinear LES models, hybrid RANS-LES and RANS-Numerical-LES (RANS-NLES) methods. Flow and heat transfer predictions using these techniques are in good agreement with each other and experimental data for a range of grid resolutions. Using second order central differences, the RANS-NLES method performs well for all simulations. © 2011 Elsevier Inc.
Resumo:
Hybrid methods based on the Reynolds Averaged Navier Stokes (RANS) equations and the Large Eddy Simulation (LES) formulation are investigated to try and improve the accuracy of heat transfer and surface temperature predictions for electronics systems and components. Two relatively low Reynolds number flows are studied using hybrid RANS-LES, RANS-Implicit-LES (RANS-ILES) and non-linear LES models. Predictions using these methods are in good agreement with each other, even using different grid resolutions. © 2008 IEEE.
Resumo:
A review of computational aeroacoustics (CCA) was made for application in electronics cooler noise. Computational aeroacoustics encompasses all numerical methods where the purposes is to predict the noise emissions from a simulated flow. Numerical simulation of the flow inside and around heat sinks and fans can lead to a prediction of the emitted noise while they are still in the design phase. Direct CCA is theoretically the best way to predict flow-based acoustic phenomena numerically. It is typically used only for low-frequency sound prediction. The boundary element method offers low computational cost and does not use a computational grid, but instead use vortex-surface calculations to determine tonal noise. Axial fans are commonly used to increase the airflow and thus the heat transfer over the heat sinks within the computer cases. Very detailed source simulations in the fan and heat sink region coupled with the use of analogy methods could result in excellent simulation results with a reasonable computational effort.
Resumo:
In the past years, organic materials have been extensively investigated as an electronic material for organic field effect transistors (OFETs). In this paper, we briefly summarize the current status of organic field effect transistors including materials design, device physics, molecular electronics and the application of carbon nanotubes in molecular electronics. Future prospects and investigations required to improve the OFET performance are also involved.