86 resultados para sloping side walls


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A series of dynamic centrifuge tests on reduced scale models of flexible retaining structures were conducted on the Turner beam centrifuge at the Schofield Centre of the University of Cambridge. The paper illustrates the main results of the experimental work in terms of observed amplifications of ground motion and mobilised shear stiffness and damping ratio for all tests. The experimental results for one test on a pair of cantilevered walls in dense sand are also presented in terms of measured bending moments and horizontal displacements of the walls during (maximum values) and at the end of (residual values) each seismic event. Finally, the experimental data are discussed in the light of the results obtained from dynamic numerical analyses of the behaviour of cantilevered walls under real seismic actions. © 2010 Taylor & Francis Group, London.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes an experimental investigation of the behaviour of embedded retaining walls under seismic actions. Nine centrifuge tests were carried out on reduced-scale models of pairs of retaining walls in dry sand, either cantilevered or with one level of props near the top. The experimental data indicate that, for maximum accelerations that are smaller than the critical limit equilibrium value, the retaining walls experience significant permanent displacements under increasing structural loads, whereas for larger accelerations the walls rotate under constant internal forces. The critical acceleration at which the walls start to rotate increases with increasing maximum acceleration. No significant displacements are measured if the current earthquake is less severe than earthquakes previously experienced by the wall. The increase of critical acceleration is explained in terms of redistribution of earth pressures and progressive mobilisation of the passive strength in front of the wall. The experimental data for cantilevered retaining walls indicate that the permanent displacements of the wall can be reasonably predicted adopting a Newmark-type calculation with a critical acceleration that is a fraction of the limit equilibrium value.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many typical ground improvement techniques that are used for liquefaction remediation, such as in situ densification, are not appropriate for application under existing buildings and more novel techniques are required. This paper describes centrifuge tests investigating the performance of rigid containment walls as a liquefaction remediation method. A simple frame structure, founded on a deep layer of loose, liquefiable sand was tested under earthquake shaking. Centrifuge tests were then carried out with containment walls around the base of the structure, extending through the full depth of the liquefiable layer and also partial depth. It is found that rigid containment walls can be very effective in reducing structural settlements primarily by preventing lateral movement of the foundation sand but the impermeability of the walls may also be important. Improvements in structural settlement are observed even when the walls do not extend through the full depth of the liquefiable layer, if the depth of the walls is greater than the depth of the free field liquefaction. In addition, it is found that the accelerations of the structure are not increased, provided there is no rigid, structural connection between the structure and the containment walls. © 2012 World Scientific Publishing Company.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to understand how unburned hydrocarbons emerge from SI engines and, in particular, how non-fuel hydrocarbons are formed and oxidized, a new gas sampling technique has been developed. A sampling unit, based on a combination of techniques used in the Fast Flame Ionization Detector (FFID) and wall-mounted sampling valves, was designed and built to capture a sample of exhaust gas during a specific period of the exhaust process and from a specific location within the exhaust port. The sampling unit consists of a transfer tube with one end in the exhaust port and the other connected to a three-way valve that leads, on one side, to a FFID and, on the other, to a vacuum chamber with a high-speed solenoid valve. Exhaust gas, drawn by the pressure drop into the vacuum chamber, impinges on the face of the solenoid valve and flows radially outward. Once per cycle during a specified crank angle interval, the solenoid valve opens and traps exhaust gas in a storage unit, from which gas chromatography (GC) measurements are made. The port end of the transfer tube can be moved to different locations longitudinally or radially, thus allowing spatial resolution and capturing any concentration differences between port walls and the center of the flow stream. Further, the solenoid valve's opening and closing times can be adjusted to allow sampling over a window as small as 0.6 ms during any portion of the cycle, allowing resolution of a crank angle interval as small as 15°CA. Cycle averaged total HC concentration measured by the FFID and that measured by the sampling unit are in good agreement, while the sampling unit goes one step further than the FFID by providing species concentrations. Comparison with previous measurements using wall-mounted sampling valves suggests that this sampling unit is fully capable of providing species concentration information as a function of air/fuel ratio, load, and engine speed at specific crank angles. © Copyright 1996 Society of Automotive Engineers, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ground improvement techniques can be adopted to prevent existing buildings built on liquefiable soils sustaining damage in future earthquakes. Impermeable geomembrane containment walls may be an economic and successful technique but their design and performance are currently not well defined or well understood for this application. This paper describes centrifuge testing carried out to investigate the performance of such containment walls as a liquefaction remediation method for a single degree of freedom frame structure. The results were compared with those from similar centrifuge testing carried out with the same structure founded on unimproved sand, to assess the effectiveness of the remediation method. It was found that the geomembrane containment walls tested were effective at reducing structural settlement and did not significantly increase the accelerations transmitted to the structure. Structural settlements were reduced primarily by mobilising hoop stress and preventing lateral soil movement. By preventing surface drainage, a decrease in the volume change of the foundation sand was also observed. In addition, the impermeability of the walls may be important as this prevented rapid migration of pore water fromthe free field to the foundation region.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cement-bentonite (CB) cutoff walls have long been used to control ground water flow and contaminant migration at polluted sites. Hydraulic conductivity and unconfined compressive strength are two short-term properties often used by industry and owners in CB specification and are important parameters discussed in this paper. For polluted sites, long-term compatibility is also an important issue. These properties are coupled to a number of external factors including the mix design, construction sequence, presence/absence of contaminants at the site. Additional short-term properties for engineering assessment include the stressstrain characteristics in both drained and undrained shear in both with and without confinement as well as one-dimensional consolidation properties. Long term CB properties are affected by aging, reaction chemistry, drying, in situ stress state, and interaction with the polluted environment. © 2013 Taylor & Francis Group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The discusser read with interest the paper by Diakoumi & Powrie (2013) proposing an interesting method for the analysis of propped flexible retaining walls based on the mobilisation of active and passive pressures on the wall due to movement of wall segments. An assumed deformation mechanism within the soil is used to estimate the strain associated with rotation of a particular wall segment. This mechanism is then superposed for each wall segment, the resulting earth pressures are calculated; the equality between the wall bending moments implied by equilibrium and those required to achieve the appropriate bending of the wall is used to calculate the rotation of each segment. Although the method of analysis provides insight into the conservatism of conventional design calculations for different wall flexibilities, there are two aspects of the paper which provoke further discussion.