102 resultados para fault recovery
Resumo:
Nowadays, control systems are involved in nearly all aspects of our lives. They are all around us, but their presence is not always really apparent. They are in our kitchens, in our DVD-players, computers and our cars. They are found in elevators, ships, aircraft and spacecraft. Control systems are present in every industry, they are used to control chemical reactors, distillation columns, and nuclear power plants. They are constantly and inexhaustibly working, making our life more comfortable and more efficient...until the system fails. © 2010 Springer-Verlag Berlin Heidelberg.
Resumo:
This paper develops an algorithm for finding sparse signals from limited observations of a linear system. We assume an adaptive Gaussian model for sparse signals. This model results in a least square problem with an iteratively reweighted L2 penalty that approximates the L0-norm. We propose a fast algorithm to solve the problem within a continuation framework. In our examples, we show that the correct sparsity map and sparsity level are gradually learnt during the iterations even when the number of observations is reduced, or when observation noise is present. In addition, with the help of sophisticated interscale signal models, the algorithm is able to recover signals to a better accuracy and with reduced number of observations than typical L1-norm and reweighted L1 norm methods. ©2010 IEEE.
Resumo:
Product recovery is beset by uncertainty regarding the quality of end-of-life (EOL) products, and in order to ascertain the reusability of these products, they have to undergo expensive tests. This undermines the profitability of the recovery process. The key to improve the effectiveness of product recovery is to improve the quality of information available before testing. Emerging data capture technologies can significantly improve the availability of information. However, in order to maximise the potential of these technologies, appropriate decision-making algorithms that exploit such information must be developed. We model the recovery process using a decision-theoretic approach, and derive strategies to ascertain the reusability of EOL products, and also to decide when tests are beneficial. We show that improving the quality of information leads to increase in effectiveness of the recovery process by reducing the need for tests. Copyright © 2009 Inderscience Enterprises Ltd.
Resumo:
We discuss solvability issues of H_-/H_2/infinity optimal fault detection problems in the most general setting. A solution approach is presented which successively reduces the initial problem to simpler ones. The last computational step generally may involve the solution of a non-standard H_-/H_2/infinity optimization problem for which we discuss possible solution approaches. Using an appropriate definition of the H- index, we provide a complete solution of this problem in the case of H2-norm. Furthermore, we discuss the solvability issues in the case of H-infinity-norm.
Resumo:
Large digital chips use a significant amount of energy to distribute a multi-GHz clock. By discharging the clock network to ground every cycle, the energy stored in this large capacitor is wasted. Instead, the energy can be recovered using an on-chip DC-DC converter. This paper investigates the integration of two DC-DC converter topologies, boost and buck-boost, with a high-speed clock driver. The high operating frequency significantly shrinks the required size of the L and C components so they can be placed on-chip; typical converters place them off-chip. The clock driver and DC-DC converter are able to share the entire tapered buffer chain, including the widest drive transistors in the final stage. To achieve voltage regulation, the clock duty cycle must be modulated; implying only single-edge-triggered flops should be used. However, this minor drawback is eclipsed by the benefits: by recovering energy from the clock, the output power can actually exceed the additional power needed to operate the converter circuitry, resulting in an effective efficiency greater than 100%. Furthermore, the converter output can be used to operate additional power-saving features like low-voltage islands or body bias voltages. ©2008 IEEE.
Resumo:
We discuss solvability issues of ℍ -/ℍ 2/∞ optimal fault detection problems in the most general setting. A solution approach is presented which successively reduces the initial problem to simpler ones. The last computational step generally may involve the solution of a non-standard ℍ -/ ℍ 2/∞ optimization problem for which we discuss possible solution approaches. Using an appropriate definition of the ℍ -- index, we provide a complete solution of this problem in the case of ℍ 2-norm. Furthermore, we discuss the solvability issues in the case of ℍ ∞-norm. © 2011 IEEE.
Resumo:
There is potential to extract energy from wastewater in a number of ways, including: kinetic energy using micro-hydro systems, chemical energy through the incineration of sludge, biomass energy from the biogas produced after anaerobic sludge digestion, and thermal energy as heat. This paper considers the last option and asks how much heat could be recovered under UK climatic conditions and can this heat be used effectively by wastewater treatment plants to reduce their carbon footprint? Four wastewater treatment sites in southern England are investigated and the available heat that can be recovered at those sites is quantified. Issues relating to the environmental, economic and practical constraints on how energy can be realistically recovered and utilised are discussed .The results show there is a definite possibility for thermal energy recovery with potential savings at some sites of up to 35,000 tonnes of total long-cycle carbon equivalent (fossil fuel) emissions per year being achievable. The paper also shows that the financial feasibility of three options for using the heat (either for district heating, sludge drying or thermophilic heating in sludge digestion processes) is highly dependant upon the current shadow price of carbon. Without the inclusion of the cost of carbon, the financial feasibility is significantly limited. An environmental constraint for the allowable discharge temperature of effluent after heat-extraction was found to be the major limitation to the amount of energy available for recovery. The paper establishes the true potential of thermal energy recovery from wastewater in English conditions and the economic feasibility of reducing the carbon footprint of wastewater treatment operations using this approach.
Resumo:
A superconducting fault current limiter (SFCL) for 6.6 kV and 400 A installed in a cubicle for a distribution network substation was conceptually designed. The SFCL consists of parallel- and series-connected superconducting YBCO elements and a limiting resistor. Before designing the SFCL, some tests were carried out. The width and length of each element used in the tests are 30 mm and 210 mm, respectively. The element consists of YBCO thin film of about 200 nm in thickness on cerium dioxide (CeO2) as a cap-layer on a sapphire substrate by metal-organic deposition with a protective metal coat. In the tests, characteristics of each element, such as over-current, withstand-voltage, and so on, were obtained. From these characteristics, series and parallel connections of the elements, called units, were considered. The characteristics of the units were obtained by tests. From the test results, a single phase prototype SFCL was manufactured and tested. Thus, an SFCL rated at 6.6 kV and 400 A can be designed. © 2009 IEEE.
Resumo:
Superconducting Fault Current Limiters (SFCLs) are able to reduce fault currents to an acceptable value, reducing potential mechanical and thermal damage to power system apparatus and allowing more flexibility in power system design and operation. The device can also help avoid replacing circuit breakers whose capacity has been exceeded. Due to limitations in current YBCO thin film manufacturing processes, it is not easy to obtain one large thin film that satisfies the specifications for high voltage and large current applications. The combination of standardized thin films has merit to reduce costs and maintain device quality, and it is necessary to connect these thin films in different series and parallel configurations in order to meet these specifications. In this paper, the design of a resistive type SFCL using parallel-connected YBCO thin films is discussed, including the role of a parallel resistor and the influence of individual thin film characteristics, based on both theory and experimental results. © 2009 IEEE.