117 resultados para aperture-coupled-striplines


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Synchronization phenomena in a fluid dynamical analogue of atmospheric circulation is studied experimentally by investigating the dynamics of a pair of thermally coupled, rotating baroclinic annulus systems. The coupling between the systems is in the well-known master-slave configuration in both periodic and chaotic regimes. Synchronization tools such as phase dynamics analysis are used to study the dynamics of the coupled system and demonstrate phase synchronization and imperfect phase synchronization, depending upon the coupling strength and parameter mismatch.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we demonstrate synchronization of two electrically coupled MEMS oscillators incorporating nearly identical silicon tuning fork microresonators. It is seen that as the output of the oscillators are coupled, they exhibit a synchronized response wherein the output amplitudes and signal-to-noise ratios of the two oscillators are improved relative to the case where the two oscillators are uncoupled. The observed output frequency of each oscillator before coupling is 219402.4 Hz and 219403.6 Hz respectively. In contrast, when the oscillators are driven simultaneously, they lock at a common output frequency of 219401.3 Hz and their outputs are found to be out-of-phase with respect to each other. A 6 dBm gain in output power and a reduction in the phase fluctuations of the output signal are observed for the coupled oscillators compared to the case when the oscillators are uncoupled. © 2011 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper investigates the effect of mode-localization that arises from structural asymmetry induced by manufacturing tolerances in mechanically coupled, electrically transduced Si MEMS resonators. We demonstrate that in the case of such mechanically coupled resonators, the achievable series motional resistance (R x) is dependent not only on the quality factor (Q) but also on the variations in the eigenvector of the chosen mode of vibration induced by mode localization due to manufacturing tolerances during the fabrication process. We study this effect of mode-localization both theoretically and experimentally in two pairs of coupled double-ended tuning fork resonators with different levels of initial structural asymmetry. The measured series R x is minimal when the system is close to perfect symmetry and any deviation from structural symmetry induced by fabrication tolerances leads to a degradation in the effective R x. Mechanical tuning experiments of the stiffness of one of the coupled resonators was also conducted to study variations in R x as a function of structural asymmetry within the system, the results of which demonstrated consistent variations in motional resistance with predictions. © 2012 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The free vibrational characteristics of coupled conical-cylindrical shells is presented. The equations of motion for the cylindrical shell are solved using a wave approach while the equations of motion for the conical shells are solved using a power series solution. The use of both Donnell-Mushtari and Flügge equations of motion are investigated and their limitations are discussed. Results are presented in terms of natural frequencies for different boundary conditions and the purely torsional mode solution is described. The results from the analytical model presented are compared with those obtained from a finite element model solved with Nastran and other data available in literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents numerical analysis of the thermally actuated superconducting flux pump. Visualization of the behavior of the magnetic flux helps our understanding of flux injection mechanism. In addition, in order to confirm validity of the result, we conducted a preliminary flux pump experiment. This result qualitatively agrees well with the experimental one. The flux pump system utilizes a particular behavior that permeability of some materials such as Gadolinium is sensitive to the temperature. In this paper a simple heater is used to control the flux pump system. © 2010 IEEE.