96 resultados para Seismic 4D
Resumo:
Residential RC framed structures suffered heavily during the 2001 Bhuj earthquake in Gujarat, India. These types of structures also saw severe damage in other earthquakes such as the 1999 Kocaeli earthquake in Turkey and 921 Ji-Ji earthquake in Taiwan. In this paper the seismic response of residential structures was investigated using physical modelling. Idealised soft storey and top heavy, two degrees of freedom (2DOF) portal frame structures were developed and tested on saturated and dry sand models at 25 g using the Schofield Centre 10-m Beam Centrifuge. It was possible to recreate observed field behaviour using these models. As observed in many of the recent earthquakes, soft storey structures were found to be particularly vulnerable to seismic loads. Elastic response spectra methods are often used in the design of simple portal frame structures. The seismic risk of these structures can be significantly increased due to modifications such as removal of a column or addition of heavy water tanks on the roof. The experimental data from the dynamic centrifuge tests on such soft storey or top-heavy models was used to evaluate the predictions obtained from the response spectra. Response spectra were able to predict seismic response during small to moderate intensity earthquakes, but became inaccurate during strong earthquakes and when soil structure interaction effects became important. Re-evaluation of seismic risk of such modified structures is required and time domain analyses suggested by building codes such as IBC, UBC or NEHRP may be more appropriate. © Springer 2006.
Resumo:
The seismic performance of waterfront cantilever sheet pile retaining walls is of continuing interest to geotechnical engineers as these structures suffer severe damage and even complete failure during earthquakes. This is often precipitated by liquefaction of the surrounding soil, either in the backfill or in front of the wall. This paper presents results from a series of small-scale plane strain models that were tested on a 1-g shaking table and recorded using a high-speed, high-resolution digital camera. The technique of Particle Image Velocimetry (PIV) was applied in order to allow the failure mechanisms to be visualised. It is shown that using PIV analyses it is possible to obtain failure mechanisms for a cantilever wall in liquefiable soil. These failure mechanisms are compared with those obtained for a cantilever wall in dry soil, previously carried out at a similar scale. It was observed that seismic liquefaction causes significant displacement in much larger zones of soil near the retaining wall compared to an equivalent dry case. The failure mechanism for a cantilever wall with liquefiable backfill, but with a remediated zone designed not to liquefy, is also presented and compared to the unremediated case.
Resumo:
An investigation into the seismic behaviour of municipal solid waste (MSW) landfills by dynamic centrifuge testing was undertaken. This paper presents physical modelling of MSW landfills for dynamic centrifuge testing, with regard to the following research areas: 1. amplification characteristics of municipal solid waste; 2. tension induced in geomembranes placed on landfill slopes due to earthquake loading; 3. damage to landfill liners due to liquefaction of foundation soil. A model waste, that has engineering properties similar to MSW, is presented. A model geomembrane that can be used in centrifuge tests is also presented. Results of dynamic centrifuge tests with the model geomembrane showed that an earthquake loading induces additional permanent tension (∼25%) in the geomembrane. © 2006 Taylor & Francis Group.
Resumo:
Many typical liquefaction remediation techniques are not appropriate for application under existing buildings and more novel techniques are required. This paper describes centrifuge tests investigating the performance of cementation as a liquefaction remediation method. Two soil profiles with the same superstructure were tested under earthquake shaking. The first profile consisted of a deep layer of loose, liquefiable sand. The second comprised a shallow layer of loose sand overlying dense sand. Centrifuge tests were carried out with a cemented zone underneath the structure, through the full depth of the liquefiable layers and also partial depth. The superstructure was modelled as a single-degree-offreedom system. It is found that a cemented zone through the full depth of a liquefiable layer results in considerable reduction of structural settlements. Increased magnitude and higher frequency accelerations are transmitted to the structure but, depending on the building characteristics, it is likely that improved overall seismic performance can be achieved. Improvements in structural settlements can also be obtained with partialdepth remediation, if the depth of the cemented zone is greater than the depth of liquefaction. This type of remediation seems to have little effect on the accelerations transmitted to the structure.
Resumo:
This study employs an analytical model to describe the rocking response of a masonry arch to in-plane seismic loading. Through evaluation of the rate of energy input to the system, the model reveals the ground motions that cause maximum rocking amplification. An experimental investigation of small-scale masonry arches subjected to past earthquake time histories is used to evaluate the analytical model and to explore arch rocking behaviour. The results demonstrate that rocking amplification can occur, but is highly sensitive to slight variations in the ground motion. Thus, the accuracy to which the arch response can be predicted is brought into perspective. The concept that the primary impulse of an expected ground motion is fundamentally important in predicting arch collapse is evaluated in light of the developed energy approach. Finally, a statistical method is proposed for predicting the probability of arch collapse during seismic loading.
Resumo:
Centrifuge testing has been undertaken to investigate instability failure of pile groups during seismic liquefaction, with specific reference to the 'top-down' propagation of liquefaction during the earthquake and to account for initial imperfections in pile geometry. The results of these tests were used to validate numerical models within the finite element program ABAQUS, based on the popular p-y analysis method. Pseudostatic classical and post-buckling analyses were conducted to examine the collapse behaviour of the pile groups and were found to give reasonable predictions of collapse load and conservative predictions of the associated deflection conditions. This numerical model was compared to currently published methods which were found to over-predict collapse loads. The resulting insights into the collapse of axially loaded pile groups revealed that the failure load is strongly dependent on both the depth of liquefaction propagation and initial imperfections, which reduce the collapse load.
Resumo:
This paper examines the settlement of instrumented 2 × 2 model pile groups in liquefiable soil based on the results of dynamic centrifuge tests. The piles are end-bearing in dense sand, and are instrumented such that base, shaft and total pile load components can be measured. The data suggest that the overall co-seismic group settlement is accrued from incremental settlements of the individual piles as the group rocks under the action of the kinematic and inertial lateral loads. A Newmarkian framework for describing this behaviour is presented in which permanent settlement is incremented whenever the load in any of the piles exceeds the capacity of the soil to support the pile. This bearing capacity of the piles in liquefied soil is estimated based on measured dynamic soil properties during shaking and observations of the changes in load carried by the piles. The contribution of the pile cap in reducing settlement is also discussed. © 2008 ASCE.
Resumo:
An investigation into the seismic behaviour of municipal solidwaste (MSW) landfills by dynamic centrifuge testing was undertaken. This paper presents physical modelling of MSW landfills for dynamic centrifuge testing, with regard to the following research areas: 1. amplification characteristics of municipal solid waste; 2. tension induced in geomembranes placed on landfill slopes due to earthquake loading; 3. damage to landfill liners due to liquefaction of foundation soil. A model waste, that has engineering properties similar to MSW, is presented. A model geomembrane that can be used in centrifuge tests is also presented. Results of dynamic centrifuge tests with the model geomembrane showed that an earthquake loading induces additional permanent tension (∼25%) in the geomembrane. © 2006 Taylor & Francis Group, London.
Resumo:
The seismic design for offshore foundations is based predominantly on experience onshore. This paper describes the results of dynamic centrifuge tests performed to validate the performance of a suction caisson installed in normally consolidated clay. The main objective is to evaluate the likely plastic displacement under different shaking levels. Permanent displacement results indicate that the displacements experienced are well within the allowable movement for the foundation considered, even though a strength based design approach would consider this to be a failure. Larger earthquakes are seen to produce comparatively smaller displacements. It is concluded that the when designing for seismic loading, if some displacement is permissible then a performance-based approach allowing some displacement proves significantly less conservative than a purely strength-based design. It is also concluded that dynamic response analyses should consider the strength of soil, as this can act as a fuse against large amplitude shear waves. © 2011 Taylor & Francis Group, London.
Resumo:
Failure of retaining walls is observed after many recent seismic events. Design of these walls are based on the pseudo-static force designs based on the Mononobe-Okabe earth pressure coefficient equations. However, it is clear that there are limitations attached with this approach. This paper investigates the seismic behaviour of sheet pile retaining walls using dynamic centrifuge testing facilities. In addition to using bending moment strain gauges on the wall, new generation earth pressure cells have also been used to investigate the generation of active and passive earth pressures. The results indicate that Mononobe-Okabe equations give relatively good estimates of active earth pressures but may be over-predicting passive earth pressures at certain peak ground acceleration levels. Based on this series of centrifuge tests it is concluded that earth pressure cells are successful in providing good qualitative data, but need to be supplemented by good calibration methods. © 2010 Taylor & Francis Group, London.
Resumo:
In the framework of the Italian research project ReLUIS-DPC, a set of centrifuge tests were carried out at the Schofield Centre in Cambridge (UK) to investigate the seismic behaviour of tunnels. Four samples of dry sand were prepared at different densities, in which a small scale model of circular tunnel was inserted, instrumented with gauges measuring hoop and bending strains. Arrays of accelerometers in the soil and on the box allowed the amplification of ground motion to be evaluated; LVDTs measured the soil surface settlement. This paper describes the main results of this research, showing among others the evolution of the internal forces during the model earthquakes at significant locations along the tunnel lining. © 2010 Taylor & Francis Group, London.
Resumo:
Distributed hybrid testing is a natural extension to and builds upon the local hybrid testing technique. Taking advantage of the hybrid nature of the test, it allows a sharing of resources and expertise between researchers from different disciplines by connecting multiple geographically distributed sites for joint testing. As part of the UK-NEES project, a successful series of three-site distributed hybrid tests have been carried out between Bristol, Cambridge and Oxford Universities. The first known multi-site distributed hybrid tests in the UK, they connected via a dedicated fibre network, using custom software, the geotechnical centrifuge at Cambridge to structural components at Bristol and Oxford. These experiments were to prove the connection and useful insights were gained into the issues involved with this distributed environment. A wider aim is towards providing a flexible testing framework to facilitate multi-disciplinary experiments such as the accurate investigation of the influence of foundations on structural systems under seismic and other loading. Time scaling incompatibilities mean true seismic soil structure interaction using a centrifuge at g is not possible, though it is clear that distributed centrifuge testing can be valuable in other problems. Development is continuing to overcome the issues encountered, in order to improve future distributed tests in the UK and beyond.
Resumo:
Shearing rate is among the most important factors affecting the undrained shear strength of clays. In particular, for seismic or storm-wave loading conditions, the shearing rate is much higher than that used in many common laboratory or field tests. The testing program described here evaluates the effect of peripheral velocity on the undrained strength inferred from the shear vane test. The study was conducted on a lightly cemented bentonite-kaolinite mixture manufactured in the laboratory, which possesses many characteristics similar to those of natural materials. Results show that the shear strength increases with increasing peripheral velocity, while the residual shear strength seems to be nearly independent of rotation rate.
Resumo:
Assessment of seismic performance and estimation of permanent displacements for submerged slopes require the accurate description of the soil's stress-strain-strength relationship under irregular cyclic loading. The geological profile of submerged slopes on the continental shelf typically consists of normally to lightly overconsolidated clays with depths ranging from a few meters to a few hundred meters and very low slope angles. This paper describes the formulation of a simplified effective-stress-based model, which is able to capture the key aspects of the cyclic behavior of normally consolidated clays. The proposed constitutive law incorporates anisotropic hardening and bounding surface principles to allow the user to simulate different shear strain and stress reversal histories as well as provide realistic descriptions of the accumulation of plastic shear strains and excess pore pressure during successive loading cycles. (C) 2000 Published by Elsevier Science Ltd. | Assessment of seismic performance and estimation of permanent displacements for submerged slopes require the accurate description of the soil's stress-strain-strength relationship under irregular cyclic loading. The geological profile of submerged slopes on the continental shelf typically consists of normally to lightly overconsolidated clays with depths ranging from a few meters to a few hundred meters and very low slope angles. This paper describes the formulation of a simplified effective-stress-based model, which is able to capture the key aspects of the cyclic behavior of normally consolidated clays. The proposed constitutive law incorporates anisotropic hardening and bounding surface principles to allow the user to simulate different shear strain and stress reversal histories as well as provide realistic descriptions of the accumulation of plastic shear strains and excess pore pressures during successive loading cycles.