133 resultados para Healthy user Bias


Relevância:

20.00% 20.00%

Publicador:

Resumo:

CLADP is an engineering software program developed at Cambridge University for the interactive computer aided design of feedback control systems. CLADP contains a wide range of tools for the analysis of complex systems, and the assessment of their performance when feedback control is applied, thus enabling control systems to be designed to meet difficult performance objectives. The range of tools within CLADP include the latest techniques in the field whose central theme is the extension of classical frequency domain concepts (well known and well proven for single loop systems) to multivariable or multiloop systems, and by making extensive use of graphical presentation information is provided in a readily understood form.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have investigated a resonant refractive nonlinearity in a semiconductor waveguide by measuring intensity dependent phase shifts and bias-dependent recovery times. The measurements were performed on an optimized 750-μm-long AR coated buried heterostructure MQW p-i-n waveguide with a bandedge at 1.48 μm. Figure 1 shows the experimental arrangement. The mode-locked color center laser was tuned to 50 meV beyond the bandedge and 8 ps pulses with peak incident power up to 57 W were coupled into the waveguide. Some residual bandtail absorption remains at this wavelength and this is sufficient to cause carriers to be photogenerated and these give rise to a refractive nonlinearity, predominantly by plasma and bandfilling effects. A Fabry-Perot interferometer is used to measure the spectrum of the light which exits the waveguide. The nonlinearity within the guide causes self phase modulation (SPM) of the light and a study of the spectrum allows information to be recovered on the magnitude and recovery time of the nonlinear phase shift with a reasonable degree of accuracy. SPM spectra were recorded for a variety of pulse energies coupled into he unbiased waveguide. Figure 2 shows the resultant phase shift measured from the SPM spectra as a function of pulse energy. The relationship is a linear one, indicating that no saturation of the nonlinearity occurs for coupled pulse energies up to 230 pJ. A π phase shift, the minimum necessary for an all-optical switch, is obtained for a coupled pulse energy of 57 pJ while the maximum phase shift, 4 π, was measured for 230 pJ. The SPM spectra were highly asymmetric with pulse energy shifted to higher frequencies. Such spectra are characteristic of a slow, negative nonlinearity. This relatively slow speed is expected for the unbiased guide as the recovery time will be of the order of the recombination time of the photogenerated electrons, about 1 ns for InGaAsP material. In order to reduce the recovery time of the nonlinearity, it is necessary to remove the photogenerated carriers from the waveguide by a process other than recombination. One such technique is to apply a reverse bias to the waveguide in order to sweep the carriers out. Figure 3 shows the effect on the recovery time of the nonlinearity of applying reverse bias to the waveguide for 230 pJ coupled power. The recovery time was reduced from one much longer than the length of the pulse, estimated to be about 1 ns, at zero bias to 18 ± 3 ps for a bias voltage greater than -4 V. This compares with a value of 24 ps obtained in a bulk waveguide.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For increasing the usability of a medical device the usability engineering standards IEC 60601-1-6 and IEC 62366 suggest incorporating user information in the design and development process. However, practice shows that integrating user information and the related investigation of users, called user research, is difficult in the field of medical devices. In particular, identifying the most appropriate user research methods is a difficult process. This difficulty results from the complexity of the medical device industry, especially with respect to regulations and standards, the characteristics of this market and the broad range of potential user research methods available from various research disciplines. Against this background, this study aimed at guiding designers and engineers in selecting effective user research methods according to their stage in the design process. Two approaches are described which reduce the complexity of method selection by summarizing the high number of methods into homogenous method classes. These approaches are closely connected to the medical device industry characteristic design phases and therefore provide the possibility of selecting design-phase- specific user research methods. In the first approach potential user research methods are classified after their characteristics in the design process. The second approach suggests a method summarization according to their similarity in the data collection techniques and provides an additional linkage to design phase characteristics. Both approaches have been tested in practice and the results show that both approaches facilitate user research method selection. © 2009 Springer-Verlag.