91 resultados para harmonic approximation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coherent coupling between a large number of qubits is the goal for scalable approaches to solid state quantum information processing. Prototype systems can be characterized by spectroscopic techniques. Here, we use pulsed-continuous wave microwave spectroscopy to study the behavior of electrons trapped at defects within the gate dielectric of a sol-gel-based high-k silicon MOSFET. Disorder leads to a wide distribution in trap properties, allowing more than 1000 traps to be individually addressed in a single transistor within the accessible frequency domain. Their dynamical behavior is explored by pulsing the microwave excitation over a range of times comparable to the phase coherence time and the lifetime of the electron in the trap. Trap occupancy is limited to a single electron, which can be manipulated by resonant microwave excitation and the resulting change in trap occupancy is detected by the change in the channel current of the transistor. The trap behavior is described by a classical damped driven simple harmonic oscillator model, with the phase coherence, lifetime and coupling strength parameters derived from a continuous wave (CW) measurement only. For pulse times shorter than the phase coherence time, the energy exchange between traps, due to the coupling, strongly modulates the observed drain current change. This effect could be exploited for 2-qubit gate operation. The very large number of resonances observed in this system would allow a complex multi-qubit quantum mechanical circuit to be realized by this mechanism using only a single transistor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adopting square wave excitation to drive induction motors (IMs) can substantially reduce inverter switching losses. However, the low-order time harmonics inherent in the output voltage generates parasitic torques that degrade motor performance and reduce efficiency. In this paper, a novel harmonic elimination modulation technique with full voltage control is studied as an interesting and alternative means of operating small (<1kW) IM drives efficiently. A fully verified harmonic elimination scheme, which removes the 5th, 7th, 11th, 13th and 17 th time harmonics, was implemented and applied to an IGBT driven IM. The power losses incurred in the inverter and the IM as a result of the switching scheme have been determined. © 2008 Crown copyright.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over recent years academia and industry have engaged with the challenge of model testing deepwater structures at conventional scales. One approach to the limited depth problem has been to truncate the lines. This concept will be introduced, highlighting the need to better understand line dynamic processes. The type of line truncation developed here models the upper sections of each line in detail, capturing wave action and all coupling effects with the vessel, terminating to an approximate analytical model that aims to simulate the remainder of the line. A rationale for this is that in deep water transverse elastic waves of a line are likely to decay before they are reflected at the seabed because of nonlinear hydrodynamic drag forces. The first part of this paper is centered on verification of this rationale. A simplified model of a mooring line that describes the transverse dynamics in wave frequency is used, adopting the equation of motion of an inextensible taut string. The line is submerged in still water, one end fixed at the bottom the other assumed to follow the vessel response, which can be harmonic or random. A dimensional analysis, supported by exact benchmark numerical solutions, has shown that it is possible to produce a universal curve for the decay of transverse vibrations along the line, which is suitable for any kind of line with any top motion. This has a significant engineering benefit, allowing for a rapid assessment of line dynamics - it can be useful in deciding whether a truncated line model is appropriate, and if so, at which point truncation might be applied. This is followed by developing a truncation mechanism, formulating an end approximation that can reproduce the correct impedance, had the line been continuous to full depth. It has been found that below a certain length criterion, which is also universal, the transverse vibrational characteristics for each line are inertia driven. As such the truncated model can assume a linear damper whose coefficient depends on the line properties and frequency of vibration. Copyright © 2011 by the International Society of Offshore and Polar Engineers (ISOPE).