108 resultados para Photothermal transparent transducer


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The supra-molecular self-assembly of peptides and proteins is a process which underlies a range of normal and aberrant biological pathways in nature, but one which remains challenging to monitor in a quantitative way. We discuss the experimental details of an approach to this problem which involves the direct measurement in vitro of mass changes of the aggregates as new molecules attach to them. The required mass sensitivity can be achieved by the use of a quartz crystal transducer-based microbalance. The technique should be broadly applicable to the study of protein aggregation, as well as to the identification and characterisation of inhibitors and modulators of this process.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This report presents work from the first nine month of a project investigating design methodologies and selection tools to promote innovations in sports equipment. Particular consideration is given to product design improvements and new market adoption of advanced materials and processes. Our aim is to couple appropriately similar technologies so as to provide a method of transfer between sports equipment designs. We would like to make barriers between isolated sports equipment markets more transparent without releasing proprietary information. A brief history of sports equipment design is included; issues particularly relevant to material and process technologies are outlined for sports equipment. A start has been made on a software program to express most of this information in a concise and accessible format. The methodology is reviewed with some industrial case studies. There is a need for further research to extend and address the design issues raised in this document; a suggested research programme is attached.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper we report the development of 1.4 kV 25 A PT and NPT Trench IGBTs with ultra-low on-resistance, latch-up free operation and highly superior overall performance when compared to previously reported DMOS IGBTs in the same class. We have fabricated both PT and transparent anode NPT devices to cover a wide range of applications which require very low on-state losses or very fast time with ultra-low switching losses. The minimum forward voltage drop at the standard current density of 100A/cm2 was 1.1 V for PT non-irradiated devices and 2.1 V for 16 MRad PT irradiated devices. The non-irradiated transparent emitter NPT structure has a typical forward voltage drop of 2.2 V, a turn-off time below 100 ns and turn-off energy losses of 11.2 mW/cm2 at 125 C. The maximum controllable current density was in excess of 1000A/cm2.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Here we demonstrate that a free-standing carbon nanotube (CNT) array can be used as a large surface area and high porosity 3D platform for molecular imprinted polymer (MIP), especially for surface imprinting. The thickness of polymer grafted around each CNT can be fine-tuned to imprint different sizes of target molecules, and yet it can be thin enough to expose every imprint site to the target molecules in solution without sacrificing the capacity of binding sites. The performance of this new CNT-MIP architecture was first assessed with a caffeine-imprinted polypyrrole (PPy) coating on two types of CNT arrays: sparse and dense CNTs. Real-time pulsed amperometric detection was used to study the rebinding of the caffeine molecules onto these CNT-MIPPy sensors. The dense CNT-MIPPy sensor presented the highest sensitivity, about 15 times better when compared to the conventional thin film, whereas an improvement of 3.6 times was recorded on the sparse CNT. However, due to the small tube-to-tube spacing in the dense CNT array, electrode fouling was observed during the detection of concentrated caffeine in phosphate buffer solution. A new I-V characterization method using pulsed amperometry was introduced to investigate the electrical characterization of these new devices. The resistance value derived from the I-V plot provides insight into the electrical conductivity of the CNT transducer and also the effective surface area for caffeine imprinting.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This review is about the development of three-dimensional (3D) ultrasonic medical imaging, how it works, and where its future lies. It assumes knowledge of two-dimensional (2D) ultrasound, which is covered elsewhere in this issue. The three main ways in which 3D ultrasound may be acquired are described: the mechanically swept 3D probe, the 2D transducer array that can acquire intrinsically 3D data, and the freehand 3D ultrasound. This provides an appreciation of the constraints implicit in each of these approaches together with their strengths and weaknesses. Then some of the techniques that are used for processing the 3D data and the way this can lead to information of clinical value are discussed. A table is provided to show the range of clinical applications reported in the literature. Finally, the discussion relating to the technology and its clinical applications to explain why 3D ultrasound has been relatively slow to be adopted in routine clinics is drawn together and the issues that will govern its development in the future explored.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Advanced waveguide lasers, operating both in continuous wave and pulsed regimes, have been realized in an active phosphate glass by direct writing with femtosecond laser pulses. Stable single mode operation was obtained; the laser provided more than 50 m W in single longitudinal and transverse mode operation with 21% slope efficiency. Furthermore, by combining a high gain waveguide and an innovated fiber-pigtailed saturable absorber based on carbon nanotubes, a mode-locked ring laser providing transform limited 1.6 ps pulses was demonstrated. © 2007 IEEE.