132 resultados para Dérivés de gré à gré
Resumo:
Transient flows in a confined ventilated space induced by a buoyancy source of time-varying strength and an external wind are examined. The space considered has varying cross-sectional area with height. A generalised theoretical model is proposed to investigate the flow dynamics following the activation of an external wind and an internal source of buoyancy. To investigate the effect of geometry, we vary the angle of the wall inclination of a particular geometry in which a point source of constant buoyancy is activated in the absence of wind. Counter-intuitively the ventilation is worse and lower airflow rates are established for geometries of increasing cross-sectional areas with height. We investigate the effect of the source buoyancy strength by comparing two cases: (1) when the buoyancy input is constant and (2) when the buoyancy input gradually increases over time so that after a finite time the total buoyancy inputs for (1) and (2) are identical. The rate at which the source heat gains are introduced has a significant role on the flow behaviour as we find that, in case (2), a warmer layer and a more pronounced overshoot are obtained than in case (1). The effect of assisting and opposing wind on the transient ventilation of an enclosure of constant cross-sectional area with height and constant heat gains is examined. A Froude number Fr is used to define the relative strengths of the buoyancy-induced and wind-induced velocities and five different transient states and their associated critical Fr are identified. © 2010 Elsevier Ltd.
Resumo:
A theoretical description of the turbulent mixing within and the draining of a dense fluid layer from a box connected to a uniform density, quiescent environment through openings in the top and the base of the box is presented in this paper. This is an extension of the draining model developed by Linden et al. (Annu. Rev. Fluid Mech. vol. 31, 1990, pp. 201-238) and includes terms that describe localized mixing within the emptying box at the density interface. Mixing is induced by a turbulent flow of replacement fluid into the box and as a consequence we predict, and observe in complementary experiments, the development of a three-layer stratification. Based on the data collated from previous researchers, three distinct formulations for entrainment fluxes across density interfaces are used to account for this localized mixing. The model was then solved numerically for the three mixing formulations. Analytical solutions were developed for one formulation directly and for a second on assuming that localized mixing is relatively weak though still significant in redistributing buoyancy on the timescale of the draining process. Comparisons between our theoretical predictions and the experimental data, which we have collected on the developing layer depths and their densities show good agreement. The differences in predictions between the three mixing formulations suggest that the normalized flux turbulently entrained across a density interface tends to a constant value for large values of a Froude number FrT, based on conditions of the inflow through the top of the box, and scales as the cube of FrT for small values of FrT. The upper limit on the rate of entrainment into the mixed layer results in a minimum time (tD) to remove the original dense layer. Using our analytical solutions, we bound this time and show that 0.2tE ≈tD tE, i.e. the original dense layer may be depleted up to five times more rapidly than when there is no internal mixing and the box empties in a time tE. © 2010 Cambridge University Press.
Resumo:
We examine the role of heat source geometry in determining rates of airflow and thermal stratification in natural displacement ventilation flows. We modify existing models to account for heat sources of finite (non-zero) area, such as formed by a sun patch warming the floor of a room. Our model allows for predictions of the steady stratification and ventilation flow rates that develop in a room due to a circular heat source at floor level. We compare our theoretical predictions with predictions for the limiting cases of a point source of heat (yielding a stratified interior), and a uniformly heated floor (yielding a mixed interior). Our theory shows a smooth transition between these two limits, which themselves result in extremes of ventilation, as the ratio of the heat source radius to the room height increases. Our model for the transition from displacement to mixing ventilation is compared to previous work and demonstrates that the transition can occur for smaller sources than previously thought, particularly for rooms with large floor area compared to ceiling height. © 2009 Elsevier Ltd.
Resumo:
We present an alternative method of producing density stratifications in the laboratory based on the 'double-tank' method proposed by Oster (Sci Am 213:70-76, 1965). We refer to Oster's method as the 'forced-drain' approach, as the volume flow rates between connecting tanks are controlled by mechanical pumps. We first determine the range of density profiles that may be established with the forced-drain approach other than the linear stratification predicted by Oster. The dimensionless density stratification is expressed analytically as a function of three ratios: the volume flow rate ratio n, the ratio of the initial liquid volumes λ and the ratio of the initial densities ψ. We then propose a method which does not require pumps to control the volume flow rates but instead allows the connecting tanks to drain freely under gravity. This is referred to as the 'free-drain' approach. We derive an expression for the density stratification produced and compare our predictions with saline stratifications established in the laboratory using the 'free-drain' extension of Oster's method. To assist in the practical application of our results we plot the region of parameter space that yield concave/convex or linear density profiles for both forced-drain and free-drain approaches. The free-drain approach allows the experimentalist to produce a broad range of density profiles by varying the initial liquid depths, cross-sectional and drain opening areas of the tanks. One advantage over the original Oster approach is that density profiles with an inflexion point can now be established. © 2008 Springer-Verlag.
Resumo:
The philosophical aspects of applying the principles of biomimicry are explored in a case study of structural design. Integrating structural engineering with services engineering can be regarded, to some extent, as taking principles from biological systems and applying them to large-scale conceptual design. The end-product discussed herein a so-called load-bearing duct, a functional naturally ventilated multi-storey office building that takes the applied loading efficiently both structurally and cost-effectively giving it the potential to be sustainable throughout its design life.
Resumo:
The natural ventilation of a building, flanked by others forming urban canyons and driven by the combined forces of wind and thermal buoyancy, has been studied experimentally at small scale. The aim was to improve our understanding of the effect of the urban canyon geometry on passive building ventilation. The steady ventilation of an isolated building was observed to change dramatically, both in terms of the thermal stratification and airflow rate, when placed within the confines of urban canyons. The ventilation flows and internal stratifications observed at small scale are presented for a range of canyon widths (building densities) and wind speeds. Two typical opening arrangements are considered. Flanking an otherwise isolated building with others of similar geometry as in a typical urban canyon was shown to reverse the effect of wind on the thermally-driven ventilation. As a consequence, neglecting the surrounding geometry when designing naturally-ventilated buildings may result in poor ventilation. Further implications are discussed.