107 resultados para Gd@C82


Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report an InGaAsP/InP phase modulator operating in the 1.5μm wavelength band. Phase modulation of 7.5°/mA and 1.7°/mA of injected current have been measured for TE and TM polarised light respectively at a signal wavelength of 1.52 μm.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Local measurements of the heat transfer coefficient and pressure coefficient were conducted on the tip and near tip region of a generic turbine blade in a five-blade linear cascade. Two tip clearance gaps were used: 1.6% and 2.8% chord. Data was obtained at a Reynolds number of 2.3 × 10 5 based on exit velocity and chord. Three different tip geometries were investigated: a flat (plain) tip, a suction-side squealer, and a cavity squealer. The experiments reveal that the flow through the plain gap is dominated by flow separation at the pressure-side edge and that the highest levels of heat transfer are located where the flow reattaches on the tip surface. High heat transfer is also measured at locations where the tip-leakage vortex has impinged onto the suction surface of the aerofoil. The experiments are supported by flow visualisation computed using the CFX CFD code which has provided insight into the fluid dynamics within the gap. The suction-side and cavity squealers are shown to reduce the heat transfer in the gap but high levels of heat transfer are associated with locations of impingement, identified using the flow visualisation and aerodynamic data. Film cooling is introduced on the plain tip at locations near the pressure-side edge within the separated region and a net heat flux reduction analysis is used to quantify the performance of the successful cooling design. copyright © 2005 by ASME.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effects of varying corona surface treatment on ink drop impact and spreading on a polymer substrate have been investigated. The surface energy of substrates treated with different levels of corona was determined from static contact angle measurement by the Owens and Wendt method. A drop-on-demand print-head was used to eject 38 μm diameter drops of UV-curable graphics ink travelling at 2.7 m/s on to a flat polymer substrate. The kinematic impact phase was imaged with a high speed camera at 500k frames per second, while the spreading phase was imaged at 20k frames per secoiui. The resultant images were analyzed to track the changes in the drop diameter during the different phases of drop spreading. Further experiments were carried out with white-light intetferometry to accurately measure the final diameter of drops which had been printed on different corona treated substrates and UV cured. The results are correlated to characterize the effects of corona treatment on drop impact behavior and final print quality.

Relevância:

10.00% 10.00%

Publicador: