57 resultados para helical twist angle


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The twist elastic constant, K2, and the rotational viscosity coefficient, γ1, are of importance when the response lime for the in-plane switching mode is studied. Since adding dopants is one technique to improve the response characteristics, the effect of dopants on these physical properties is significant. The effect on K2 and γ1 of adding alkyl(alkoxy) phenylcyclopentenones and alkyl(alkoxy) cyanobiphenyls to the base mixture ZLI-4792 together with their temperature dependence have been investigated using different temperature scales. The reduced temperature scale showed the effect of these dopants on K2 is small. On the other hand, the temperature dependence of γ1 depends on both the absolute temperature scale and the reduced temperature scale. Therefore, it is clear that the choice of temperature scale with which to compare γ1 for different systems raises fundamental questions which way not have a unique answer. 2000 OPA (Overseas Publishers Association) N.V. Published by license under the Gordon and Breach Science Publishers imprint.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel pair of the E- and Z-isomeric 1R,4R-2-(4-heptyloxyphenyl)-benzylidene-p-menthan-3-ones has been prepared and the influence of distinctions in their molecular geometry on macroscopic properties of liquid crystal systems with the induced supra-molecular helical structure has been studied. The significantly lower helical twisting power of the chiral Z-isomer in comparison with that of E- one has been confirmed in the case of induced cholesteric systems based on 4-pentyl-4-cyanobiphenyl. The phase behavior and ferroelectric characteristics have been investigated for smectic-C* compositions based on the eutectic mixture of the homological 4-hexyloxyphenyl-4'-hexyloxy- and 4-hexyloxyphenyl-4'-octyloxybenzoates containing the novel isomeric chiral dopants. The spontaneous polarisation of the opposite signs induced by the isomeric chiral components has been revealed for the compositions studied. Distinctions in phase states, absolute values of the spontaneous polarization, smectic tilt angle and rotation viscosity of the systems obtained are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The peel test is commonly used to determine the strength of adhesive joints. In its simplest form, a thin flexible strip which has been bonded to a rigid surface is peeled from the substrate at a constant rate and the peeling force which is applied to the debonding surfaces by the tension in the tape is measured. Peeling can be carried out with the peel angle, i.e. the angle made by the peel force with the substrate surface, from any value above about 10° although peeling tests at 90 and 180° are most common. If the tape is sufficiently thin for its bending resistance to be negligibly small then as well as the debonding or decohesion energy associated with the adhesive in and around the point of separation, the relation between the peeling force and the peeling angle is influenced both by the mechanical properties of the tape and any pre-strain locked into the tape during its application to the substrate. The analytic solution for a tape material which can be idealised as elastic perfectly-plastic is well established. Here, we present a more general form of analysis, applicable in principle to any constitutive relation between tape load and tape extension. Non-linearity between load and extension is of increasing significance as the peel angle is decreased: the model presented is consistent with existing equations describing the failure of a lap joint between non-linear materials. The analysis also allows for energy losses within the adhesive layer which themselves may be influenced by both peel rate and peel angle. We have experimentally examined the application of this new analysis to several specific peeling cases including tapes of cellophane, poly-vinyl chloride and PTFE. © 2005 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

(1R,4R)-2-(4-Hydroxybenzylidene)- and (1R,4R)-2-(4′-hydroxybiphenyl- 4-yl)methylene-p-menthan-3-ones were synthesized by condensation of (-)-menthone with O-tetrahydropyran-2-yl derivatives of 4-hydroxybenzaldehyde and 4′-hydroxy-4-formylbiphenyl, respectively, in a DMSO - base medium followed by the removal of the protective group. The reactions of these hydroxy derivatives with 4-alkylbenzoic, 4-alkyloxybenzoic, trans-4-alkylcyclohexane-4- carboxylic, and 4′-alkylbiphenyl-4-carboxylic acids afforded three series of new chiral esters. Compounds containing the arylidene moiety with three benzene rings were found to exhibit liquid-crystalline properties. The characteristic features of these compounds are discussed based on the results of studies by polarizing microscopy, differential scanning calorimetry, and small-angle X-ray scattering. It was found that the mesomorphic compounds under study can form a smectic A mesophase, twist grain boundary mesophases (TGBA), and blue phases in a wide temperature range. Upon dissolution of certain of chiral compounds in 4′-cyano-4-pentylbiphenyl, a rather high twisting power and the thermal stabilizing effect on mesophases were observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of high tilt angle FLC SLM for optical interconnects was discussed. The transmissive SLM was designed as a 320×1 pixels glass SLM with 20 μm pitch pixels and 2 μm pixel deadspace. The SLM was fabricated using standard class 100 cleanroom facilities to make a glass on glass 1D SLM. The results show that a N×N optical switch can be built using the two-hologram architecture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple laser refractometer based on the detection of the critical angle for liquids is presented. The calibrated refractometer presents up to 0.000 11 of uncertainty when the refractive index is in the range between 1.300 00 and 1.340 00. The experimental setup is easy to construct and the material needed is available at most optics laboratories. The calibration method is simple and can be used in other devices. The refractive index measurements in aqueous solutions of sodium chloride were carried out to test the device and a linear dependence between the refractive index and the salt concentration was found. © 2006 American Institute of Physics.