37 resultados para floor joists
Resumo:
We compare natural ventilation flows established by a range of heat source distributions at floor level. Both evenly distributed and highly localised line and point source distributions are considered. We demonstrate that modelling the ventilation flow driven by a uniformly distributed heat source is equivalent to the flow driven by a large number of localised sources. A model is developed for the transient flow development in a room with a uniform heat distribution and is compared with existing models for localised buoyancy inputs. For large vent areas the flow driven by localised heat sources reaches a steady state more rapidly than the uniformly distributed case. For small vent areas there is little difference in the transient development times. Our transient model is then extended to consider the time taken to flush a neutrally buoyant pollutant from a naturally ventilated room. Again comparisons are drawn between uniform and localised (point and line) heat source geometries. It is demonstrated that for large vent areas a uniform heat distribution provides the fastest flushing. However, for smaller vent areas, localised heat sources produce the fastest flushing. These results are used to suggest a definition for the term 'natural ventilation efficiency', and a model is developed to estimate this efficiency as a function of the room and heat source geometries. © 2006 Elsevier Ltd. All rights reserved.
Resumo:
The airflow and thermal stratification produced by a localised heat source located at floor level in a closed room is of considerable practical interest and is commonly referred to as a 'filling box'. In rooms with low aspect ratios H/R ≲ 1 (room height H to characteristic horizontal dimension R) the thermal plume spreads laterally on reaching the ceiling and a descending horizontal 'front' forms separating a stably stratified, warm upper region from cooler air below. The stratification is well predicted for H/R ≲ 1 by the original filling box model of Baines and Turner (J. Fluid. Mech. 37 (1968) 51). This model represents a somewhat idealised situation of a plume rising from a point source of buoyancy alone-in particular the momentum flux at the source is zero. In practical situations, real sources of heating and cooling in a ventilation system often include initial fluxes of both buoyancy and momentum, e.g. where a heating system vents warm air into a space. This paper describes laboratory experiments to determine the dependence of the 'front' formation and stratification on the source momentum and buoyancy fluxes of a single source, and on the location and relative strengths of two sources from which momentum and buoyancy fluxes were supplied separately. For a single source with a non-zero input of momentum, the rate of descent of the front is more rapid than for the case of zero source momentum flux and increases with increasing momentum input. Increasing the source momentum flux effectively increases the height of the enclosure, and leads to enhanced overturning motions and finally to complete mixing for highly momentum-driven flows. Stratified flows may be maintained by reducing the aspect ratio of the enclosure. At these low aspect ratios different long-time behaviour is observed depending on the nature of the heat input. A constant heat flux always produces a stratified interior at large times. On the other hand, a constant temperature supply ultimately produces a well-mixed space at the supply temperature. For separate sources of momentum and buoyancy, the developing stratification is shown to be strongly dependent on the separation of the sources and their relative strengths. Even at small separation distances the stratification initially exhibits horizontal inhomogeneity with localised regions of warm fluid (from the buoyancy source) and cool fluid. This inhomogeneity is less pronounced as the strength of one source is increased relative to the other. Regardless of the strengths of the sources, a constant buoyancy flux source dominates after sufficiently large times, although the strength of the momentum source determines whether the enclosure is initially well mixed (strong momentum source) or stably stratified (weak momentum source). © 2001 Elsevier Science Ltd. All rights reserved.
Resumo:
We investigate the mechanisms involved in the breakdown of the viscous regime in riblets, with a view to determining the point of optimum performance, where drag reduction ceases to be proportional to the riblet size. This occurs empirically for a groove cross-section $A_g^+ \approx 120^+$. To study the interaction of the riblets with the overlaying turbulent flow, we systematically conduct DNSes in a ribbed turbulent channel with increasing riblet size. The conditionally averaged crossflow above and within the grooves reveals a mean recirculation bubble that exists up to the point of viscous breakdown, isolating the groove floor from the overlying crossflow, and preventing the high momentum fluid from entering the grooves. We do not find evidence of outside vortices lodging within the grooves until $A_g^+ \approx 400$, which is well past the drag minimum, and already into the drag increasing regime. Interestingly, as the bubble breaks down, we observe that quasi-two-dimensional spanwise structures form just above the riblets, similar to those observed above porous surfaces and plant canopies, which appear to be involved in the performance degradation.
Resumo:
A separated oblique shock reflection on the floor of a rectangular cross-section wind tunnel has been investigated at M=2.5. The study aims to determine if and how separations occurring in the corners influence the main interaction as observed around the centreline of the floor. By changing the size of the corner separations through localised suction and small corner obstructions it was shown that the shape of the separated region in the centre was altered considerably. The separation length along the floor centreline was also modified by changes to the corner separation. A simple physical model has been proposed to explain the coupling between these separated regions based on the existence of compression or shock waves caused by the displacement effect of corner separation. These corner shocks alter the adverse pressure gradient imposed on the boundary-layer elsewhere which can lead to local reductions or increases of separation length. It is suggested that a typical oblique shock wave/boundary-layer interaction in rectangular channels features several zones depending on the relative position of the corner shocks and the main incident shock wave. Based on these findings the dependence of centre-line separation length on effective wind tunnel width is hypothesised. This requires further verification through experiments or computation. © 2013 by H. Babinsky.
Resumo:
We examine theoretically the transient displacement flow and density stratification that develops within a ventilated box after two localized floor-level heat sources of unequal strengths are activated. The heat input is represented by two non-interacting turbulent axisymmetric plumes of constant buoyancy fluxes B1 and B2 > B1. The box connects to an unbounded quiescent external environment of uniform density via openings at the top and base. A theoretical model is developed to predict the time evolution of the dimensionless depths λj and mean buoyancies δj of the 'intermediate' (j = 1) and 'top' (j = 2) layers leading to steady state. The flow behaviour is classified in terms of a stratification parameter S, a dimensionless measure of the relative forcing strengths of the two buoyant layers that drive the flow. We find that dδ1/dτ α 1/λ1 and dδ2/dτ α 1/λ2, where τ is a dimensionless time. When S 1, the intermediate layer is shallow (small λ1), whereas the top layer is relatively deep (large λ2) and, in this limit, δ1 and δ2 evolve on two characteristically different time scales. This produces a time lag and gives rise to a 'thermal overshoot', during which δ1 exceeds its steady value and attains a maximum during the transients; a flow feature we refer to, in the context of a ventilated room, as 'localized overheating'. For a given source strength ratio ψ = B1/B2, we show that thermal overshoots are realized for dimensionless opening areas A < Aoh and are strongly dependent on the time history of the flow. We establish the region of {A, ψ} space where rapid development of δ1 results in δ1 > δ2, giving rise to a bulk overturning of the buoyant layers. Finally, some implications of these results, specifically to the ventilation of a room, are discussed. © Cambridge University Press 2013.
Resumo:
Previous studies of transonic shock control bumps have often been either numerical or experimental. Comparisons between the two have been hampered by the limitations of either approach. The present work aims to bridge the gap between computational fluid dynamics and experiment by planning a joint approach from the outset. This enables high-quality validation data to be produced and ensures that the conclusions of either aspect of the study are directly relevant to the application. Experiments conducted with bumps mounted on the floor of a blowdown tunnel were modified to include an additional postshock adverse pressure gradient through the use of a diffuser as well as introducing boundary-layer suction ahead of the test section to enable the in-flow boundary layer to be manipulated. This has the advantage of being an inexpensive and highly repeatable method. Computations were performed on a standard airfoil model, with the flight conditions as free parameters. The experimental and computational setups were then tuned to produce baseline conditions that agree well, enabling confidence that the experimental conclusions are relevant. The methods are then applied to two different shock control bumps: a smoothly contoured bump, representative of previous studies, and a novel extended geometry featuring a continuously widening tail, which spans the wind-tunnel width at the rear of the bump. Comparison between the computational and experimental results for the contour bump showed good agreement both with respect to the flow structures and quantitative analysis of the boundary-layer parameters. It was seen that combining the experimental and numerical data could provide valuable insight into the flow physics, which would not generally be possible for a one-sided approach. The experiments and computational fluid dynamics were also seen to agree well for the extended bump geometry, providing evidence that, even though thebumpinteracts directly with the wind-tunnel walls, it was still possible to observe the key flow physics. The joint approach is thus suitable even for wider bump geometries. Copyright © 2013 by S. P. Colliss, H. Babinsky, K. Nubler, and T. Lutz. Published by the American Institute of Aeronautics and Astronautics, Inc.
Developing ISO 14649-based conversational programming system for multi-channel complex machine tools
Resumo:
A multi-channel complex machine tool (MCCM) is a versatile machining system equipped with more than two spindles and turrets for both turning and milling operations. Despite the potential of such a tool, the value of the hardware is largely dependent on how the machine tools are effectively programmed for machining. In this paper we consider a shop-floor programming system based on ISO 14649 (called e-CAM), the international standard for the interface between computer-aided manufacture (CAM) and computer numerical control (CNC). To be deployed in practical industrial usage a great deal of research has to be carried out. In this paper we present: 1) Design consideration for an e-CAM system, 2) The architecture design of e-CAM, 3) Major algorithms to fulfill the modules defined in the architecture, and 4) Implementation details.