51 resultados para Selective harvesting


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work demonstrates transmission at 2.5 Gbit/s across two wavelength-division multiplexing (WDM) network nodes, constructed using counter-propagating semiconductor optical amplifier (SOA) wavelength converters and an integrated wavelength-selective router separated by 45 km of fiber, with an overall penalty of 0.6 dB. Minimal degradation of the eye diagram is evident across the whole system. Full utilization of the capacity of the router would allow an aggregate 360-Gbit/s node capacity for a WDM channel of 2.5 Gb/s.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

All-optical routing of 2.5Gbit/s WDM signals across two cascaded Optical Cross Connects(OXCs) with a penalty of only 0.6dB has been demonstrated using tuneable wavelength converters and a passive WDM router.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

All-optical routing of 2.5Gbit/s WDM signals across two cascaded Optical Cross Connects(OXCs) with a penalty of only 0.6dB has been demonstrated using tuneable wavelength converters and a passive WDM router.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Piezoelectric systems are viewed as a promising approach to energy harvesting from environmental vibrations. The energy harvested from real vibration sources is usually difficult to estimate analytically. Therefore, it is hard to optimise the associated energy harvesting system. This work investigates the optimisation of a piezoelectric cantilever system using a genetic algorithm based approach with numerical simulations. The genetic algorithm globally considers the effects of each parameter to produce an optimal frequency response to scavenge more energy from the real vibrations while the conventional sinusoidal based method can only optimise the resistive load for a given resonant frequency. Experimental acceleration data from the vibrations of a vehicle-excited manhole cover demonstrates that the optimised harvester automatically selects the right frequency and also synchronously optimises the damper and the resistive load. This method shows great potential for optimizing the energy harvesting systems with real vibration data. ©2009 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Receptor-based detection of pathogens often suffers from non-specific interactions, and as most detection techniques cannot distinguish between affinities of interactions, false positive responses remain a plaguing reality. Here, we report an anharmonic acoustic based method of detection that addresses the inherent weakness of current ligand dependant assays. Spores of Bacillus subtilis (Bacillus anthracis simulant) were immobilized on a thickness-shear mode AT-cut quartz crystal functionalized with anti-spore antibody and the sensor was driven by a pure sinusoidal oscillation at increasing amplitude. Biomolecular interaction forces between the coupled spores and the accelerating surface caused a nonlinear modulation of the acoustic response of the crystal. In particular, the deviation in the third harmonic of the transduced electrical response versus oscillation amplitude of the sensor (signal) was found to be significant. Signals from the specifically-bound spores were clearly distinguishable in shape from those of the physisorbed streptavidin-coated polystyrene microbeads. The analytical model presented here enables estimation of the biomolecular interaction forces from the measured response. Thus, probing biomolecular interaction forces using the described technique can quantitatively detect pathogens and distinguish specific from non-specific interactions, with potential applicability to rapid point-of-care detection. This also serves as a potential tool for rapid force-spectroscopy, affinity-based biomolecular screening and mapping of molecular interaction networks. © 2011 Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report selective tunnelling through a nanographene intermolecular tunnel junction achieved via scanning tunnelling microscope tip functionalization with hexa-peri-hexabenzocoronene (HBC) molecules. This leads to an offset in the alignment between the energy levels of the tip and the molecular assembly, resulting in the imaging of a variety of distinct charge density patterns in the HBC assembly, not attainable using a bare metallic tip. Different tunnelling channels can be selected by the application of an electric field in the tunnelling junction, which changes the condition of the HBC on the tip. Density functional theory-based calculations relate the imaged HBC patterns to the calculated molecular orbitals at certain energy levels. These patterns bear a close resemblance to the π-orbital states of the HBC molecule calculated at the relevant energy levels, mainly below the Fermi energy of HBC. This correlation demonstrates the ability of an HBC functionalized tip as regards accessing an energy range that is restricted to the usual operating bias range around the Fermi energy with a normal metallic tip at room temperature. Apart from relating to molecular orbitals, some patterns could also be described in association with the Clar aromatic sextet formula. Our observations may help pave the way towards the possibility of controlling charge transport between organic interfaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Each mode of a 2 km 50 μ OM2 grade multimode fiber is precisely excited at multiple orientations using a binary phase spatial light modulator (SLM) to generate a detailed modal description of the fiber and minimize modal dispersion over 4.5 THz of optical bandwidth. © 2012 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on the growth of single-walled carbon nanotubes from a monometallic Co catalyst on an oxidized Si wafer support by the most simple growth recipe (vacuum annealing, growth by undiluted C 2H 2). Nevertheless, multiwavelength Raman spectroscopy and transmission electron spectroscopy show a remarkable selectivity for chiral indices and thus, e.g., high abundance with a single chirality representing 58% of all semiconducting tubes. In situ x-ray photoelectron spectroscopy monitors the catalyst chemistry during carbon nanotube growth and shows interfacial Co-Si interactions that may help to stabilize the nanoparticle/nanotube diameter. We outline a two-mechanism model explaining the selective growth. © 2012 American Physical Society.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Porous structures are used in orthopaedics to promote biological fixation between metal implant and host bone. In order to achieve rapid and high volumes of bone ingrowth the structures must be manufactured from a biocompatible material and possess high interconnected porosities, pore sizes between 100 and 700 microm and mechanical strengths that withstand the anticipated biomechanical loads. The challenge is to develop a manufacturing process that can cost effectively produce structures that meet these requirements. The research presented in this paper describes the development of a 'beam overlap' technique for manufacturing porous structures in commercially pure titanium using the Selective Laser Melting (SLM) rapid manufacturing technique. A candidate bone ingrowth structure (71% porosity, 440 microm mean pore diameter and 70 MPa compression strength) was produced and used to manufacture a final shape orthopaedic component. These results suggest that SLM beam overlap is a promising technique for manufacturing final shape functional bone ingrowth materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Mode Selective Switch based around an LCoS Spatial Light Modulator is demonstrated to optically demultiplex modes with the same propagation constants to the same output fibres, using a common phase mask for all channels. © 2012 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pulses of 15 psec duration were generated by an injection laser with an external dispersive resonator operating in the active mode-locking regime. This regime was attained by subjecting the laser diode to a current of high frequency equal to the intermode interval in the external resonator. The duration of the pulses was determined by an autocorrelation method in which the second harmonic was generated in an LiIO//3 crystal.