37 resultados para Inside the urban block


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The natural ventilation of a building, flanked by others forming urban canyons and driven by the combined forces of wind and thermal buoyancy, has been studied experimentally at small scale. The aim was to improve our understanding of the effect of the urban canyon geometry on passive building ventilation. The steady ventilation of an isolated building was observed to change dramatically, both in terms of the thermal stratification and airflow rate, when placed within the confines of urban canyons. The ventilation flows and internal stratifications observed at small scale are presented for a range of canyon widths (building densities) and wind speeds. Two typical opening arrangements are considered. Flanking an otherwise isolated building with others of similar geometry as in a typical urban canyon was shown to reverse the effect of wind on the thermally-driven ventilation. As a consequence, neglecting the surrounding geometry when designing naturally-ventilated buildings may result in poor ventilation. Further implications are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Underground space is commonly exploited both to maximise the utility of costly land in urban development and to reduce the vertical load acting on the ground. Deep excavations are carried out to construct various types of underground infrastructure such as deep basements, subways and service tunnels. Although the soil response to excavation is known in principle, designers lack practical calculation methods for predicting both short- and long-term ground movements. As the understanding of how soil behaves around an excavation in both the short and long term is insufficient and usually empirical, the judgements used in design are also empirical and serious accidents are common. To gain a better understanding of the mechanisms involved in soil excavation, a new apparatus for the centrifuge model testing of deep excavations in soft clay has been developed. This apparatus simulates the field construction sequence of a multi-propped retaining wall during centrifuge flight. A comparison is given between the new technique and the previously used method of draining heavy fluid to simulate excavation in a centrifuge model. The new system has the benefit of giving the correct initial ground conditions before excavation and the proper earth pressure distribution on the retaining structures during excavation, whereas heavy fluid only gives an earth pressure coefficient of unity and is unable to capture any changes in the earth pressure coefficient of soil inside the zone of excavation, for example owing to wall movements. Settlements of the ground surface, changes in pore water pressure, variations in earth pressure, prop forces and bending moments in the retaining wall are all monitored during excavation. Furthermore, digital images taken of a cross-section during the test are analysed using particle image velocimetry to illustrate ground deformation and soil–structure interaction mechanisms. The significance of these observations is discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Time-resolved particle image velocimetry (PIV) has been performed inside the nozzle of a commercially available inkjet print-head to obtain the time-dependent velocity waveform. A printhead with a single transparent nozzle 80 μm in orifice diameter was used to eject single droplets at a speed of 5 m/s. An optical microscope was used with an ultra-high-speed camera to capture the motion of particles suspended in a transparent liquid at the center of the nozzle and above the fluid meniscus at a rate of half a million frames per second. Time-resolved velocity fields were obtained from a fluid layer approximately 200 μm thick within the nozzle for a complete jetting cycle. A Lagrangian finite-element numerical model with experimental measurements as inputs was used to predict the meniscus movement. The model predictions showed good agreement with the experimental results. This work provides the first experimental verification of physical models and numerical simulations of flows within a drop-on-demand nozzle. © 2012 Society for Imaging Science and Technology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a method for characterizing the propagation of the magnetic flux in an artificially drilled bulk high-temperature superconductor (HTS) during a pulsed-field magnetization. As the magnetic pulse penetrates the cylindrical sample, the magnetic flux density is measured simultaneously in 16 holes by means of microcoils that are placed across the median plane, i.e. at an equal distance from the top and bottom surfaces, and close to the surface of the sample. We discuss the time evolution of the magnetic flux density in the holes during a pulse and measure the time taken by the external magnetic flux to reach each hole. Our data show that the flux front moves faster in the median plane than on the surface when penetrating the sample edge; it then proceeds faster along the surface than in the bulk as it penetrates the sample further. Once the pulse is over, the trapped flux density inside the central hole is found to be about twice as large in the median plane than on the surface. This ratio is confirmed by modelling.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A superconducting magnetic shield can be built as a stack of several sections of milled 2G coated conductors. Each section consists of a closed loop where persistent currents can flow and provide a strong attenuation of external dc magnetic fields. The purpose of the present work is to study experimentally several geometries of such magnetic shields made out of YBa2Cu 3O7 (YBCO) coated conductors from SuperPower. Our aim is to investigate in detail the influence of the aspect ratio and the number of layers of the assembly on the magnetic shielding properties. In order to do so, the magnetic shield is subjected to an axial quasi-static ('dc') magnetic field ramped slowly at a fixed sweep rate. A Hall probe is used to measure the local magnetic induction inside the assembly as a function of the applied magnetic induction. Results show that the shielding factor, SF, (defined as the ratio between the applied magnetic induction and the magnetic induction measured inside the shield) is improved for increasing aspect ratios of the global coated conductor assembly and that the threshold magnetic induction (defined for SF = 10) increases with the number of layers. Using a double layer of 18 sections at T = 77K , dc magnetic fields up to 56 mT can be shielded by a factor larger than 10. Finally, the effect of an air gap of constant width between coated conductor sections is also characterized. © 2002-2011 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The optical, structural and electrical properties of poly(3,4- ethylenedioxythiophene):poly(4-styrenesulfonic acid) (PEDOT:PSS) thin films printed by roll-to-roll gravure have been investigated. Corona treatment has been applied to enhance the adhesion of PEDOT:PSS on PolyEthylene Terephthalate (PET) web. It has been found that there was a stronger in-depth surface modification of PET with the increase of corona efficiency; however, the adhesion of PEDOT:PSS was not actually affected. Also, Spectroscopic Ellipsometry and Atomic Force Microscopy have been used to extract information on the mechanisms that define PEDOT:PSS properties. The increase of the drying temperature of the PEDOT:PSS films has been found to reduce the remaining water inside the films and lead to the decrease of the PEDOT:PSS particles size. © 2011 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The three-stage low-pressure model steam turbine at the Institute of Thermal Turbomachinery and Machinery Laboratory (ITSM) was used to study the impact of three different steam inlet temperatures on the homogeneous condensation process and the resulting wetness topology. The droplet spectrum as well as the particle number concentration were measured in front of the last stage using an optical-pneumatic probe. At design load, condensation starts inside the stator of the second stage. A change in the steam inlet temperature is able to shift the location of condensation onset within the blade row up- or downstream and even into adjoining blade passages, which leads to significantly different local droplet sizes and wetness fractions due to different local expansion rates. The measured results are compared to steady three-dimensional computational fluid dynamics calculations. The predicted nucleation zones could be largely confirmed by the measurements. Although the trend of measured and calculated droplet size across the span is satisfactory, there are considerable differences between the measured and computed droplet spectrum and wetness fractions. © IMechE 2013 Reprints and permissions: sagepub.co.uk/ journalsPermissions.nav.