47 resultados para railway nystagmus


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Accurate predictions of ground-borne vibration levels in the vicinity of an underground railway are greatly sought after in modern urban centres. Yet the complexity involved in simulating the underground environment means that it is necessary to make simplifying assumptions about this system. One such commonly made assumption is to ignore the effects of neighbouring tunnels, despite the fact that many underground railway lines consist of twin-bored tunnels, one for the outbound direction and one for the inbound direction. This paper presents a unique model for two tunnels embedded in a homogeneous, elastic fullspace. Each of these tunnels is subject to both known, dynamic train forces and dynamic cavity forces. The net forces acting on the tunnels are written as the sum of those tractions acting on the invert of a single tunnel, and those tractions that represent the motion induced by the neighbouring tunnel. By apportioning the tractions in this way, the vibration response of a two-tunnel system is written as a linear combination of displacement fields produced by a single-tunnel system. Using Fourier decomposition, forces are partitioned into symmetric and antisymmetric modenumber components to minimise computation times. The significance of the interactions between two tunnels is quantified by calculating the insertion gains, in both the vertical and horizontal directions, that result from the existence of a second tunnel. The insertion-gain results are shown to be localised and highly dependent on frequency, tunnel orientation and tunnel thickness. At some locations, the magnitude of these insertion gains is greater than 20 dB. This demonstrates that a high degree of inaccuracy exists in any surface vibration prediction model that includes only one of the two tunnels. This novel two-tunnel solution represents a significant contribution to the existing body of research into vibration from underground railways, as it shows that the second tunnel has a significant influence on the accuracy of vibration predictions for underground railways. © 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Accurate predictions of ground-borne vibration levels in the vicinity of an underground railway are greatly sought in modern urban centers. Yet the complexity involved in simulating the underground environment means that it is necessary to make simplifying assumptions about this environment. One such commonly-made assumption is to model the railway as a single tunnel, despite many underground railway lines consisting of twin-bored tunnels. A unique model for two tunnels embedded in a homogeneous, elastic full space is developed. The vibration response of this two-tunnel system is calculated using the superposition of two displacement fields: one resulting from the forces acting on the invert of a single tunnel, and the other resulting from the interaction between the tunnels. By partitioning of the stresses into symmetric and anti-symmetric mode number components using Fourier decomposition, these two displacement fields can by calculated with minimal computational requirements. The significance of the interactions between twin-tunnels is quantified by calculating the insertion gains that result from the existence of a second tunnel. The insertion-gain results are shown to be localized and highly dependent on frequency, tunnel orientation and tunnel thickness. At some locations, the magnitude of these insertion gains is greater than 20dB. This demonstrates that a high degree of inaccuracy exists in any surface vibration-prediction model that includes only one of the two tunnels. © 2012 Springer.