The sound emission from open turbulent flames is dictated by the two-point spatial correlation of rate of change of fluctuating heat release rate and this correlation has not been investigated directly in the past studies. Turbulent premixed flame data from DNS and laser diagnostics are analyzed to study this correlation function and the two-point spatial correlation of the fluctuating heat release rate. This shows that the correlation functions have simple Gaussian forms whose integral length scale is related to the laminar flame thickness and amplitude depends on the spatial distribution of the time-mean rate of heat release. These results and RANS-CFD solution of open turbulent premixed flames are post-processed to obtain the far field SPL, which agrees well with measured values. © 2010 by the American Institute of Aeronautics and Astronautics, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper contains a review of recent results concerning the parametrization of asymptotically stable linear systems using balanced realizations. Particular emphasis is given on the application of these results to system identification. This work is part of a continuing programme aimed at elucidating the role of balanced realization in system identification.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Desired performance of unpressurized integral collector storage systems hinges on the appropriate selection of storage volume and the immersed heat exchanger. This paper presents analytical results expressing the relation between storage volume, number of heat exchanger transfer units and temperature limited performance. For a system composed of a single storage element, the limiting behavior of a perfectly stratified storage element is shown to be superior to a fully-mixed storage element, consistent with more general analysis of thermal storage. Since, however, only the fully-mixed limit is readily obtainable in a physical system, the present paper also examines a division of the storage volume into separate compartments. This multi-element storage system shows significantly improved discharge characteristics as a result of improved elemental area utilization and temperature variation between elements, comparable in many cases to a single perfectly-stratified storage element. In addition, the multi-element system shows increased robustness with respect to variations in heat exchanger effectiveness and initial storage temperature.