24 resultados para active distribution system


Relevância:

40.00% 40.00%

Publicador:

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The use of anti-roll bars to provide additional roll stiffness and therefore to reduce the trade-off between ride and rollover performance has previously been studied. However, little work has been carried out to investigate the benefits of a switchable roll stiffness. Such a semi-active anti-roll system has the ability to have a low roll stiffness during straight-ahead driving for improved ride performance and high roll stiffness during cornering for improved roll performance. Modelling of such a system is conducted and the model is validated against a semi-active anti-roll system fitted to an experimental vehicle. Experimental and theoretical investigations are used to investigate the performance of such a system with several different strategies employed to switch to the high-stiffness state. The use of an air suspension on the vehicle to roll into corners is also investigated, as is the possibility of exploiting the road layout by allowing the vehicle to be in a low-roll-stiffness configuration during a corner, and then to switch to the high-roll-stiffness configuration midcorner, hence 'locking in' a roll angle. The best rollover performance improvement that was achieved was 12.5 per cent. © IMechE 2008.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A wide area and error free ultra high frequency (UHF) radio frequency identification (RFID) interrogation system based on the use of multiple antennas used in cooperation to provide high quality ubiquitous coverage, is presented. The system uses an intelligent distributed antenna system (DAS) whereby two or more spatially separated transmit and receive antenna pairs are used to allow greatly improved multiple tag identification performance over wide areas. The system is shown to increase the read accuracy of 115 passive UHF RFID tags to 100% from <60% over a 10m × 8m open plan office area. The returned signal strength of the tag backscatter signals is also increased by an average of 10dB and 17dB over an area of 10m 8m and 10m × 4m respectively. Furthermore, it is shown that the DAS RFID system has improved immunity to tag orientation. Finally, the new system is also shown to increase the tag read speed/rate of a population of tags compared with a conventional RFID system. © 2012 IEEE.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A wide area and error free ultra high frequency (UHF) radio frequency identification (RFID) interrogation system based on the use of multiple antennas used in cooperation to provide high quality ubiquitous coverage, is presented. The system uses an intelligent distributed antenna system (DAS) whereby two or more spatially separated transmit and receive antenna pairs are used to allow greatly improved multiple tag identification performance over wide areas. The system is shown to increase the read accuracy of 115 passive UHF RFID tags to 100% from <60% over a 10m x 8m open plan office area. The returned signal strength of the tag backscatter signals is also increased by an average of 10dB and 17dB over an area of 10m x 8m and 10m x 4m respectively. Furthermore, it is shown that the DAS RFID system has improved immunity to tag orientation. Finally, the new system is also shown to increase the tag read speed/rate of a population of tags compared with a conventional RFID system.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A superconducting fault current limiter (SFCL) in series with a downstream circuit breaker could provide a viable solution to controlling fault current levels in electrical distribution networks. In order to integrate the SFCL into power grids, we need a way to conveniently predict the performance of the SFCL in a given scenario. In this paper, short circuit analysis based on the electromagnetic transient program was used to investigate the operational behavior of the SFCL installed in an electrical distribution grid. System studies show that the SFCL can not only limit the fault current to an acceptable value, but also mitigate the voltage sag. The transient recovery voltage (TRV) could be remarkably damped and improved by the presence of the SFCL after the circuit breaker is opened to clear the fault. © 2007 British Crown Copyright.