22 resultados para Stagnation
Resumo:
This paper presents an assessment of the performance of an embedded propulsion system in the presence of distortion associated with boundary layer ingestion. For fan pressure ratios of interest for civil transports, the benefits of boundary layer ingestion are shown to be very sensitive to the magnitude of fan and duct losses. The distortion transfer across the fan, basically the comparison of the stagnation pressure non-uniformity downstream of the fan to that upstream of the fan, has a major role in determining the impact of boundary layer ingestion on overall fuel burn. This, in turn, puts requirements on the fidelity with which one needs to assess the distortion transfer, and thus the type of models that need to be used in such assessment. For the three-dimensional distortions associated with fuselage boundary layers ingested into a subsonic diffusing inlet, it is found that boundary layer ingestion can provide decreases in fuel burn of several per cent. It is also shown that a promising avenue for mitigating the risks (aerodynamic as well as aeromechanical) in boundary layer ingestion is to mix out the flow before it reaches the engine face.
Resumo:
If the conventional steady flow combustor of a gas turbine is replaced with a device which achieves a pressure gain during the combustion process then the thermal efficiency of the cycle is raised. All such 'Pressure Gain Combustors' (e.g. PDEs, pulse combustors or wave rotors) are inherently unsteady flow devices. For such a device to be practically installed in a gas turbine it is necessary to design a downstream row of turbine vanes which will both accept the combustors unsteady exit flow and deliver a flow which the turbine rotor can accept. The design requirements of such a vane are that its exit flow both retains the maximum time-mean stagnation pressure gain (the pressure gain produced by the combustor is not lost) and minimises the amplitude of unsteadiness (reduces unsteadiness entering the downstream rotor). In this paper the exit of the pressure gain combustor is simulated with a cold unsteady jet. The first stage vane is simulated by a one-dimensional choked ejector nozzle with no turning. The time-mean and rms stagnation pressure at nozzle exit is measured. A number of geometric configurations are investigated and it is shown that the optimal geometry both maximizes time mean stagnation pressure gain (75% of that in the exit of the unsteady jet) and minimizes the amplitude of unsteadiness (1/3 of that in the primary jet). The structure of the unsteady flow within the ejector nozzle is determined computationally. Copyright © 2009 by J Heffer and R Miller.
Resumo:
The present study aims to provide insight into the parameters affecting practical laminar-flow-control suction power requirements for a commercial laminar-flying-wing transport aircraft. It is shown that there is a minimum power requirement independent of the suction system design, associated with the stagnation pressure loss in the boundary layer. This requirement increases with aerofoil section thickness, but depends only weakly on Mach number and (for a thick, lightly loaded laminar flying wing) lift coefficient. Deviation from the optimal suction distribution, due to a practical chamber-based architecture, is found to have very little effect on the overall suction coefficient; hence, to a good approximation, the power penalty is given by the product of the optimal suction flow rate coefficient and the average skin pressure drop. In the spanwise direction, through suitable choice of chamber depth, the pressure drop due to frictional and inertial effects may be rendered negligible. Finally, if there are fewer pumps than chambers, the average pressure drop from the aerofoil surface to the pump collector ducts, rather than to the chambers, determines the power penalty. For the representative laminar-flying-wing aircraft parameters considered here, the minimum power associated with boundary-layer losses alone contributes some 80-90% of the total power requirement. © 2011 by the American Institute of Aeronautics and Astronautics, Inc.
Resumo:
An experimental investigation has been undertaken in which vortex generators (VGs) have been employed to inhibit boundary-layer separation produced by the combined adversepressure- gradient of a terminal shock-wave and subsonic diffuser. This setup has been developed as part of a program to produce a more inlet relevant flow-field using a small-scale wind tunnel than previous studies. The resulting flow is dominated by large-scale separation, and as such, is thought to be a good test-bed for flow control. In this investigation, VGs have been added to determine their potential for shock-induced separation mitigation. In line with previous studies, it was observed that the application of VGs alone was not able to significantly alleviate separation overall, because enlarged corner separations was observed. Only when control of the corner separations using corner bleed was employed alongside centre-span control using VGs was a significant improvement in both wall pressure recovery (6% increase) and stagnation pressure recovery (2.4% increase) observed. Copyright © 2012 by the American Institute of Aeronautics and Astronautics, Inc.
Resumo:
15 years ago the vertical SuperJunction (SJ) concept conceived for SJ power MOSFETs was the last, major breakthrough in the field of silicon power devices. Today, the SuperJunction MOSFET technologies have reached a mature stage characterized by gradual performance improvements. SuperJunction Insulated Gate Bipolar Transistors (SJ IGBTs) could interrupt this stagnation holding promise to revitalize voltage classes from 600 up to 1200 V. Such SJ IGBTs surpass by a very significant margin their SJ MOSFET counterparts both in terms of power handling capability, on-state and turn-off losses, all at the same time. On the higher end of the voltage class, SJ IGBTs would top the performance of 1.2 kV IGBTs by a similar margin. © 2012 IEEE.
Resumo:
The computation of both transient and steady turbulent incompressible isothermal flows is studied. The flow is very complex, having streamline curvature, large vortex structures and stagnation resulting from an impinging rectangular jet. For transient computations, the standard k-ε model is adopted. For steady flows, the k-ε, high and low Reynolds number k-l and mixing length models are tried. Zonal approaches combining the above turbulence models are also investigated. None of the models are found to give satisfactory agreement with velocity measurements.
Resumo:
To investigate whether vortex generators can be an effective form of passive flow control an experimental investigation has been conducted in a small-scale wind tunnel. With specific emphasis on supersonic inlet applications flow separation was initiated using a combined terminal shock wave and subsonic diffuser: a configuration that has been developed as a part of a program to produce a more inlet-relevant flowfield in a small-scale wind tunnel than previous studies. When flow control was initially introduced little overall flow improvement was obtained as the losses tended to be redistributed instead of removed. It became apparent that there existed a strong coupling between the center-span flow and the corner flows. As a consequence, only when flow control was applied to both the corner flows and center-span flow was a significant flow improvement obtained. When corner suction and center-span vortex generators were employed in tandem separation was much reduced and wall-pressure and stagnation pressure were notably improved. As a result, when applied appropriately, it is thought that vortex generators do have the potential to reduce the dependence on boundary-layer bleed for the purpose of separation suppression. Copyright © 2012 by Neil Titchener and Holger Babinsky. Published by the American Institute of Aeronautics and Astronautics, Inc.