73 resultados para Retaining walls.


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Rigid retaining walls are considered. Both the backfill and the soil supporting the foundation of the model wall have been made of a single dry granular soil. Attention is limited to one grain.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Two case histories on deep excavation of marine clay are used to study the use of a decision-making tool based on a new deign method called the Mobilized Strength Design (MSD) method which allows the designer to use a simple method of predicting ground displacements during deep excavation. This application can approximately satisfy both safety and serviceability requirements by predicting stresses and displacements under working conditions by introducing the concept of "Mobilizable soil strength". The new method accommodates a number of features which are important to design of underground construction between retaining walls, including different deformation mechanism in different stages of excavation. The influence of wall depth, wall flexibility and stratified ground are the major focus of this paper. These developments should make it possible for a design engineer to take informed decisions on the influence of wall stiffness, or on the need for a jet-grouted base slab, for example, without having to conduct project-specific Finite Element Analysis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper provides a case study on the deepest excavation carried out so far in the construction of the metro network in Shanghai, which typically features soft ground. The excavation is 38 m deep with retaining walls 65 m deep braced by 9 levels of concrete props. To obtain a quick and rough prediction, two centrifuge model tests were conducted, in which one is for the 'standard' section with green field surrounding and the other with an adjacent piled building. The tests were carried out in a run-stop-excavation-run style, in which excavation was conducted manually. By analyzing the lateral wall displacement, ground deformation, bending moment and earth pressure, the test results are shown to be reasonably convincing and the design and construction were validated. Such industry orientated centrifuge modeling was shown to be useful in understanding the performance of geotechnical processes, especially when engineers lack relevant field experience. © 2010 Taylor & Francis Group, London.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Failure of retaining walls is observed after many recent seismic events. Design of these walls are based on the pseudo-static force designs based on the Mononobe-Okabe earth pressure coefficient equations. However, it is clear that there are limitations attached with this approach. This paper investigates the seismic behaviour of sheet pile retaining walls using dynamic centrifuge testing facilities. In addition to using bending moment strain gauges on the wall, new generation earth pressure cells have also been used to investigate the generation of active and passive earth pressures. The results indicate that Mononobe-Okabe equations give relatively good estimates of active earth pressures but may be over-predicting passive earth pressures at certain peak ground acceleration levels. Based on this series of centrifuge tests it is concluded that earth pressure cells are successful in providing good qualitative data, but need to be supplemented by good calibration methods. © 2010 Taylor & Francis Group, London.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Water front structures have suffered significant damage in many of the recent earthquakes. These include gravity type quay walls, vertically composite walls, cantilever retaining walls, anchored bulkheads and similar structures. One of the primary causes for the poor performance of these classes of structures is the liquefaction of the foundation soil and in some instances liquefaction of the backfill soil. The liquefaction of the soil in-front of the quay wall tends to cause large lateral displacements and rotation of the wall. Often such gravity walls are placed on rubble mound deposited onto the sea bed.This paper presents finite element analyses of such a problem in which strength degradation of the foundation soil and the backfill material will be modelled using PZ mark III constitutive model. The performance of the wall in terms of its lateral displacement, vertical settlement and/or the rotation suffered by the wall will be presented. In addition, the contours of the horizontal and vertical effective stresses and the excess pore pressure ratio will be presented at different time instants together with hyrdraulic gradients. Immediately after the earthquake, the hydraulic gradients indicate migration of pore water into the region below the wall, suggesting further softening of the foundation soil below the wall.

Relevância:

30.00% 30.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador: