58 resultados para Residual generator
Resumo:
Implants of boron into silicon which has been made amorphous by silicon implantation have a shallower depth profile than the same implants into silicon. This results in higher activation and restricted diffusion of the B implants after annealing, and there are also significant differences in the microstructure after annealing compared with B implants into silicon. Rapid isothermal heating with an electron beam and furnace treatments are used to characterize the defect structure as a function of time and temperature. Defects are seen to influence the diffusion of non-substitutional boron.
Resumo:
This paper uses finite element (FE) analysis to examine the residual stresses generated during the TIG welding of aluminium aerospace alloys. It also looks at whether such an approach could be useful for evaluating the effectiveness of various residual stress control techniques. However, such simulations cannot be founded in a vacuum. They require accurate measurements to refine and validate them. The unique aspect of this work is that two powerful engineering techniques are combined: FE modelling and neutron diffraction. Weld trials were performed and the direct measurement of residual strain made using the ENGIN neutron diffraction strain scanning facility. The predicted results show an excellent agreement with experimental values. Finally this model is used to simulate a weld made using a "Low Stress No Distortion" (LSND) technique. Although the stress reduction predicted is only moderate, the study suggests the approach to be a quick and efficient means of optimising such techniques.
Resumo:
Most tribological pairs carry their service load not just once but for a very large number of repeated cycles. During the early stages of this life, protective residual stresses may be developed in the near surface layers which enable loads which are of sufficient magnitude to cause initial plastic deformation to be accommodated purely elastically in the longer term. This is an example of the phenomenon of 'shakedown' and when its effects are incorporated into the design and operation schedule of machine components this process can lead to significant increases in specific loading duties or improvements in material utilization. Although the underlying principles can be demonstrated by reference to relatively simple stress systems, when a moving Hertzian pressure distribution in considered, which is the form of loading applicable to many contact problems, the situation is more complex. In the absence of exact solutions, bounding theorems, adopted from the theory of plasticity, can be used to generate appropriate load or shakedown limits so that shakedown maps can be drawn which delineate the boundaries between potentially safe and unsafe operating conditions. When the operating point of the contact lies outside the shakedown limit there will be an increment of plastic strain with each application of the load - these can accumulate leading eventually to either component failure or the loss of material by wear. © 2005 Elsevier Ltd. All rights reserved.
Resumo:
This paper discusses the inverter ratings of Brushless Doubly-Fed Machine (BDFM) adjustable speed drive (ASD) or generator (ASG) systems. Based on the per phase equivalent circuit model, the ratings of the two inverters in a bidirectional converter are evaluated individually. An approach to minimise the total inverter rating is presented, taking into account power factor constraints of the power grid. The effects of speed deviation and control winding excitation on the inverter ratings are discussed. Predictions of inverter ratings are presented with experimental verification. A design example is also provided in which the total inverter rating is minimised for a practical BDFM based ASG system. © 2005 IEEE.
Resumo:
To investigate the flow control potential of micro-vortex generators for supersonic mixed-compression inlets, a basic model experiment has been designed which combines a normal shock wave with a subsonic diffuser. The diffuser is formed by a simple expansion corner, with a divergence angle of 6 degrees. The diffuser entry Mach numbers were M=1.3 and M=1.5 and a number of shock locations relative to the corner position were tested. Flow control was applied in the form of counter-rotating micro-vanes with heights of approximately 20% of boundary layer thickness. Furthermore, corner fences where employed to reduce sidewall effects. It was found that micro-vortex generators were able to significantly reduce the extent of flow separation under all conditions, but could not eliminate it altogether. Corner fences also demonstrated potential for improving the flow in rectangular cross section channels and the combination of corner fences with micro-vortex generators was found to give the greatest benefits. At M=1.3 the combination of corner fences and micro-vanes placed close to the diffuser entry could prevent separation for a wide range of conditions. At the higher diffuser entry Mach number the benefits of flow control were less significant although a reduction of separation size and an improved pressure recovery was observed. It is thought that micro-vortex generators can have significant flow control potential if they are placed close to the expected separation onset and when the adverse pressure gradient is not too far above the incipient separation level. The significant beneficial effects of corner fences warrant a more comprehensive further investigation. It is thought that the control methods suggested here are capable of reducing the bleed requirement on an inlet, which could provide significant performance advantages.