31 resultados para Ramp metering
Resumo:
The paper's goal is the first demonstration of the fabrication of high power Schottky diodes on synthetic diamond using oxide ramp termination. In order to allow full activated impurities at room temperature and a high hole mobility a low boron doping of the drift layer is employed. Several aspects of the manufacturing technology are presented. A termination with a small ramp angle can be obtained using only RIE technique due to diamond wafer nonuniformity (roughness). Experimental forward and reverse characteristics measured on diamond diodes are also included. © 2007 IEEE.
Resumo:
Supersonic engine intakes operating supercritically feature shock wave / boundary layer interactions (SBLIs), which are conventionally controlled using boundary layer bleed. The momentum loss of bleed flow causes high drag, compromising intake performance. Micro-ramp sub-boundary layer vortex generators (SBVGs) have been proposed as an alternative form of flow control for oblique SBLIs in order to reduce the bleed requirement. Experiments have been conducted at Mach 2.5 to characterise the flow details on such devices and investigate their ability to control the interaction between an oblique shock wave and the naturally grown turbulent boundary layer on the tunnel floor. Micro-ramps of four sizes with heights ranging from 25% to 75% of the uncontrolled boundary layer thickness were tested. The flow over all sizes of microramp was found to be similar, featuring streamwise counter-rotating vortices which entrain high momentum fluid, locally reducing the boundary layer displacement thickness. When installed ahead of the shock interaction it was found that the positioning of the micro-ramps is of limited importance. Micro-ramps did not eliminate flow separation. However, the previously two-dimensional separation was broken up into periodic three-dimensional separation zones. The interaction length was reduced and the pressure gradient across the interaction was increased.
Resumo:
Various vortex generators which include ramp, split-ramp and a new hybrid concept "ramped-vane" are investigated under normal shock conditions with a diffuser at Mach number of 1.3. The dimensions of the computational domain were designed using Reynolds Average Navier-Stokes studies to be representative of the flow in an external-compression supersonic inlet. Using this flow geometry, various vortex generator concepts were studied with Implicit Large Eddy Simulation. In general, the ramped-vane provided increased vorticity compared to the other devices and reduced the separation length downstream of the device centerline. In addition, the size, edge gap and streamwise position respect to the shock were studied for the ramped-vane and it was found that a height of about half the boundary thickness and a large trailing edge gap yielded a fully attached flow downstream of the device. This ramped-vane also provided the largest reduction in the turbulent kinetic energy and pressure fluctuations. Additional benefits include negligible drag while the reductions in boundary layer displacement thickness and shape factor were seen compared to other devices. © 2010 by Sang Lee.
Resumo:
Various vortex generators which include ramp, split-ramp and a new hybrid concept "ramped-vane" are investigated under normal shock conditions with a diffuser at Mach number of 1.3. The dimensions of the computational domain were designed using Reynolds Average Navier-Stokes studies to be representative of the flow in an external-compression supersonic inlet. Using this flow geometry, various vortex generator concepts were studied with Implicit Large Eddy Simulation. In general, the ramped-vane provided increased vorticity compared to the other devices and reduced the separation length downstream of the device centerline. In addition, the size, edge gap and streamwise position respect to the shock were studied for the ramped-vane and it was found that a height of about half the boundary thickness and a large trailing edge gap yielded a fully attached flow downstream of the device. This ramped-vane also provided the largest reduction in the turbulent kinetic energy and pressure fluctuations. Additional benefits include negligible drag while the reductions in boundary layer displacement thickness and shape factor were seen compared to other devices. © 2011 Elsevier Ltd.
Resumo:
This paper presents a comparison between SiC and diamond Schottky barrier diodes using the oxide ramp termination. The influences of the dielectric thickness and relative permittivity on the diode's electrical performance are investigated. Typical commercial drift layer parameters are used for this study. The extension of the space charge area throughout the drift region and the current distribution at breakdown are shown. The efficiency of the termination is also evaluated for both SiC and diamond diodes. © (2009) Trans Tech Publications, Switzerland.
Resumo:
A novel method for on-line topographic analysis of rough surfaces in the SEM has been investigated. It utilises a digital minicomputer configured to act as a programmable scan generator and automatic focusing unit. The computer is coupled to the microscope through digital-to-analogue converters which enable it to generate ramp waveforms allowing the beam to be scanned over a small sub-region of the field under program control. A further digital-to-analogue converter regulates the current supply to the objective lens of the microscope. The video signal is sampled by means of an analogue-to-digital converter and the resultant binary code stored in the computer's memory as an array of numbers describing relative image intensity. Computations based on the intensity gradient of the image allow the objective lens current to be found for the in-focus condition, which may be related to the working distance through a previous calibration experiment. The sensitivity of the method for detecting small height changes is theoretically of the order of 1 μm. In practice the operator specifies features of interest by means of a mobile spot cursor injected into the SEM display screen, or he may scan the specimen at sub-regions corresponding to pre-determined points on a regular grid defined by him. The operation then proceeds under program control. | A novel method for on-line topographic analysis of rough surfaces in the SEM has been investigated. It utilizes a digital minicomputer configured to act as a programmable scan generator and automatic focusing unit. A further digital-to-analog converter regulates the current supply to the objective lens of the microscope. The video signal is sampled by means of an analog-to-digital converter and the resultant binary code stored in the computer's memory as an array of numbers describing relative image intensity. The sensitivity of the method for detecting small height changes is theroretically of the order of 1 mu m.
Resumo:
A novel technique for automated topographical analysis in the SEM has been investigated. It utilizes a 16-bit minicomputer arranged to act as an automatic focusing unit. The computer is coupled to the objective lens of the microscope, by means of a digital to analogue converter, and may regulate the excitation of the lens under program control. Further digital-to-analogue converters allow the computer to act as a programmable scan generator by applying ramp waveforms to the scan amplifiers, permitting the beam to be swept over a small sub-region of the field of interest. The video signal is sampled and applied to an analogue-to-digital converter; the resultant binary numbers are stored in computer memory as an array of values representing relative image intensities within a subregion. A differencing algorithm applied to the collected data allows the level of objective lens excitation to be found at which the sharpness of the image is optimized, and the excitation may be related to the working distance for that subregion through a previous calibration experiment. The sensitivity of the method for detecting small height changes is theoretically of the order of 1 μm.
Resumo:
Indentation of linearly viscoelastic materials is explored using elastic-viscoelastic correspondence analysis for both conical-pyramidal and spherical indentation. Boltzmann hereditary integrals are used to generate displacement-time solutions for loading at constant rate and creep following ramp loading. Experimental data for triangle- and trapezoidal-loading are examined for commercially-available polymers and compared with analytical solutions. Emphasis is given to the use of multiple experiments to test the fidelity and predictive capability of the obtained material creep function. Plastic deformation occurs in sharp indentation of glassy polymers and is found to complicate the viscoelastic analysis. A new method is proposed for estimating a material time-constant from peak displacement or hardness data obtained in pyramidal indentation tests performed at different loading rates.
Resumo:
Bone is an anisotropic material, and its mechanical properties are determined by its microstructure as well as its composition. Mechanical properties of bone are a consequence of the proportions of, and the interactions between, mineral, collagen and water. Water plays an important role in maintaining the mechanical integrity of the composite, but the manner in which water interacts within the ultrastructure is unclear. Dentine being an isotropic two-dimensional structure presents a homogenous composite to examine the dehydration effects. Nanoindentation methods for determining the viscoelastic properties have recently been developed and are a subject of great interest. Here, one method based on elastic-viscoelastic correspondence for 'ramp and hold' creep testing (Oyen, J. Mater. Res., 2005) has been used to analyze viscoelastic behavior of polymeric and biological materials. The method of 'ramp and hold' allows the shear modulus at time zero to be determined from fitting of the displacement during the maximum load hold. Changes in the viscoelastic properties of bone and dentine were examined as the material was systematically dehydrated in a series of water:solvent mixes. Samples of equine dentine were sectioned and cryo-polished. Shear modulus was obtained by nanoindentation using spherical indenters with a maximum load hold of 120s. Samples were tested in different solvent concentrations sequentially, 70% ethanol to 50% ethanol, 70 % ethanol to 100% ethanol, 70% ethanol to 70% methanol to 100% methanol, and 70% ethanol to 100% acetone, after storage in each condition for 24h. By selectively removing and then replacing water from the composite, insights in to the ultrastructure of the tissue can be gained from the corresponding changes in the experimentally determined moduli, as well as an understanding of the complete reversibility of the dehydration process. © 2006 Materials Research Society.
Resumo:
A two-step viscoelastic spherical indentation method is proposed to compensate for 1) material relaxation and 2) sample thickness. In the first step, the indenter is moved at a constant speed and the reaction force is measured. In the second step, the indenter is held at a constant position and the relaxation response of the material is measured. Then the relaxation response is fit with a multi-exponential function which corresponds to a three-branch general Maxwell model. The relaxation modulus is derived by correcting the finite ramp time introduced in the first step. The proposed model takes into account the sample thickness, which is important for applications in which the sample thickness is less than ten times the indenter radius. The model is validated numerically by finite element simulations. Experiments are carried out on a 10% gelatin phantom and a chicken breast sample with the proposed method. The results for both the gelatin phantom and the chicken breast sample agree with the results obtained from a surface wave method. Both the finite element simulations and experimental results show improved elasticity estimations by incorporating the sample thickness into the model. The measured shear elasticities of the 10% gelatin sample are 6.79 and 6.93 kPa by the proposed finite indentation method at sample thickness of 40 and 20 mm, respectively. The elasticity of the same sample is estimated to be 6.53 kPa by the surface wave method. For the chicken breast sample, the shear elasticity is measured to be 4.51 and 5.17 kPa by the proposed indentation method at sample thickness of 40 and 20 mm, respectively. Its elasticity is measured by the surface wave method to be 4.14 kPa. © 2011 IEEE.
Resumo:
This paper describes a fundamental experimental study of the flow structure around a single three-dimensional (3D) transonic shock control bump (SCB) mounted on a flat surface in a wind tunnel. Tests have been carried out with a Mach 1.3 normal shock wave located at a number of streamwise positions relative to the SCB. Details of the flow have been studied using the experimental techniques of schlieren photography, surface oil flow visualization, pressure sensitive paint, and laser Doppler anemometry. The results of the work build on the findings of previous researchers and shed new light on the flow physics of 3D SCBs. It is found that spanwise pressure gradients across the SCB ramp and the shape of the SCB sides affect the magnitude and uniformity of flow turning generated by the bump, which can impact on the spanwise propagation of the quasi-two-dimensional (2D) shock structure produced by a 3DSCB. At the bump crest, vortices can form if the pressure on the crest is significantly lower than at either side of the bump. The trajectories of these vortices, which are relatively weak, are strongly influenced by any spanwise pressure gradients across the bump tail. Asignificant difference between 2D and 3D SCBs highlighted by the study is the impact of spanwise pressure gradients on 3D SCB performance. The magnitude of these spanwise pressure gradients is determined largely by SCB geometry and shock position. Copyright © 2011 by the American Institute of Aeronautics and Astronautics, Inc.
Resumo:
A number of VG configurations have been examined in a inlet relevant fiow-fleld which includes a terminal shock wave and subsequent subsonic diffuser. The flow-fleld was found to be highly sensitive to VG configuration. While the performance of one vane VG configuration was good over a wide range of streamwise positions, another quite similar vane configuration tended to perforin less well-especially when positioned further from the separation-and work is ongoing to determine the reasons behind tliis behavior. In addition, it was found that vane-type VG configurations were appreciably better at reducing separation than their micro-ramp counterparts. When combined with bleed in the centre-span region upstream of the VGs, the performance of vane type VGs was further enhanced and was the best of any configuration. © 2013 by Neil Titchener, Holger Babinsky and Eric Loth.