41 resultados para Monarchical Schemes
Resumo:
this paper quantifies effects of using three different pulse width modulation (PWM) schemes on the losses in the inverter and induction motor of a 1 kW drive. Direct measurements of losses have been made with a calorimeter. Results show that for the inverter, discontinuous PWM excitation reduces losses by up to 15% compared to sine and symmetrical space vector PWM methods. However, at a low modulation index the greater harmonic content with discontinuous PWM increased motor losses by nearly 20%. This study demonstrates the importance of careful choice of modulation scheme to achieve high overall drive efficiency. © 2005 IEEE.
Resumo:
This paper presents the results of an investigation into the impact of pulse width modulation (PWM) switching schemes on power losses in induction motors and their inverter drives. The PWM schemes considered include sinusoidal PWM, spacevector PWM and discontinuous PWM. Both experimental results and simulated predictions are presented for fractional horsepower and small integral horsepower motors. Direct loss measurements have been carried out using a calorimetric test rig; detailed simulations of the skewed motors have been carried out using multi-slice time-stepped 2D FEA. The simulated and measured losses under the different modulation schemes are compared and discussed. © 2006 IEEE.