42 resultados para Golpe de drive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A closed-loop control technique based on monitoring phase current risetime for switched reluctance (SR) motors without direct rotor-position sensors has been studied and implemented successfully. In this technique the variation in incremental phase inductance in a SR motor is used to detect rotor position. A control circuit for current-waveform-based rotor position detection has been implemented using hard-wire digital circuits. Torque-speed and system-efficiency characteristics resulting from the application of the method to a 4-kW, four-phase SR motor with an IGBT drive are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multiwavelength pulses were generated using a monolithically integrated device. The device used is an integrated InGaAs/InGaAsP/InP multi-wavelength laser fabricated by selective area regrowth. The device self pulsated on all of the four wavelength channels. 48 ps pulses were obtained which were measured by a 50GHz oscilloscope and 32GHz photodiode which was not bandwidth limited. Simultaneous multi-wavelength pulse generation was also achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Uncooled, high-speed modulation of two-contact lasers is presented with ultra-low drive currents. Practical operation at 10Gb/s up to temperatures of 85°C and extinction ratios of 6dB are found for current swings which are less than 40% of conventional lasers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper discusses the inverter ratings of Brushless Doubly-Fed Machine (BDFM) adjustable speed drive (ASD) or generator (ASG) systems. Based on the per phase equivalent circuit model, the ratings of the two inverters in a bidirectional converter are evaluated individually. An approach to minimise the total inverter rating is presented, taking into account power factor constraints of the power grid. The effects of speed deviation and control winding excitation on the inverter ratings are discussed. Predictions of inverter ratings are presented with experimental verification. A design example is also provided in which the total inverter rating is minimised for a practical BDFM based ASG system. © 2005 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adopting square wave excitation to drive induction motors (IMs) can substantially reduce inverter switching losses. However, the low-order time harmonics inherent in the output voltage generates parasitic torques that degrade motor performance and reduce efficiency. In this paper, a novel harmonic elimination modulation technique with full voltage control is studied as an interesting and alternative means of operating small (<1kW) IM drives efficiently. A fully verified harmonic elimination scheme, which removes the 5th, 7th, 11th, 13th and 17 th time harmonics, was implemented and applied to an IGBT driven IM. The power losses incurred in the inverter and the IM as a result of the switching scheme have been determined. © 2008 Crown copyright.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a solid state electrical emulator devised for laboratory testing of power conditioning electronics for direct drive linear wave energy converters (DDLWEC). Two rectification strategies are considered; a uni-directional boost topology, and an H-bridge which may be controlled in either uni- or bidirectional modes.