23 resultados para Gear selectivity
Resumo:
In a wind-turbine gearbox, planet bearings exhibit a high failure rate and are considered as one of the most critical components. Development of efficient vibration based fault detection methods for these bearings requires a thorough understanding of their vibration signature. Much work has been done to study the vibration properties of healthy planetary gear sets and to identify fault frequencies in fixed-axis bearings. However, vibration characteristics of planetary gear sets containing localized planet bearing defects (spalls or pits) have not been studied so far. In this paper, we propose a novel analytical model of a planetary gear set with ring gear flexibility and localized bearing defects as two key features. The model is used to simulate the vibration response of a planetary system in the presence of a defective planet bearing with faults on inner or outer raceway. The characteristic fault signature of a planetary bearing defect is determined and sources of modulation sidebands are identified. The findings from this work will be useful to improve existing sensor placement strategies and to develop more sophisticated fault detection algorithms. Copyright © 2011 by ASME.
Resumo:
Modeling the noise originating from a landing gear has proven to be a challenging task, because of its complicated structure. In full-scale, landing gear noise can only be investigated experimentally by source localization techniques and fly-over measurements with microphone arrays. In the present work, measurements of a Boeing B747-400 were used to determine the contribution of the landing gear to the overall noise emitted during a fly-over and how the broadband noise from the landing gear scales with the flight velocity. A tonal source from the nose landing gear was identified at 380 Hz with a harmonic at 760 Hz and it most likely originates from a cavity. It was also found that the Power Spectral Density (PSD) of the high frequency broadband component varies linearly with frequency and there is some scaling with the ow velocity. Finally, the nose landing gear was shown to be a significant contributor to the overall airframe noise as expected.
Resumo:
A potentiometric device based on interfacing a solid electrolyte oxygen ion conductor with a thin platinum film acts as a robust, reproducible sensor for the detection of hydrocarbons in high- or ultrahigh-vacuum environments. Sensitivities in the order of approximately 5 x 10(-10) mbar are achievable under open circuit conditions, with good selectivity for discrimination between n-butane on one hand and toluene, n-octane, n-hexane, and 1-butene on the other hand. The sensor's sensitivity may be tuned by operating under constant current (closed circuit) conditions; injection of anodic current is also a very effective means of restoring a clean sensing surface at any desired point. XPS data and potentiometric measurements confirm the proposed mode of sensing action: the steady-state coverage of Oa, which sets the potential of the Pt sensing electrode, is determined by the partial pressure and dissociative sticking probability of the impinging hydrocarbon. The principles established here provide the basis for a viable, inherently flexible, and promising means for the sensitive and selective detection of hydrocarbons under demanding conditions.
Resumo:
The acoustic response of conventional mechanical oscillators, such as a piezoelectric crystal, is predominantly harmonic at modest amplitudes. However, here, we observe from the electrical response that significant motional anharmonicity is introduced in the presence of attached analyte. Experiments were conducted with streptavidin-coated polystyrene microbeads of various sizes attached to a quartz crystal resonator via specific and nonspecific molecular tethers in liquid. Quantitative analysis reveals that the deviation of odd Fourier harmonics of the response caused by introduction of microbeads as a function of oscillation amplitude presents a unique signature of the molecular tether. Hence, the described anharmonic detection technique (ADT) based on this function allows screening of biomolecules and provides an additional level of selectivity in receptor-based detection that is often associated with nonspecific interactions. We also propose methods to extract mechanical force-extension characteristics of the molecular tether and activation energy using this technique.
Resumo:
This paper reports the fabrication and electrical characterization of high tuning range AlSi RF MEMS capacitors. We present experimental results obtained by a surface micromachining process that uses dry etching of sacrificial amorphous silicon to release Al-1%Si membranes and has a low thermal budget (<450 °C) being compatible with CMOS post-processing. The proposed silicon sacrificial layer dry etching (SSLDE) process is able to provide very high Si etch rates (3-15 μm/min, depending on process parameters) with high Si: SiO2 selectivity (>10,000:1). Single- and double-air-gap MEMS capacitors, as well as some dedicated test structures needed to calibrate the electro-mechanical parameters and explore the reliability of the proposed technology, have been fabricated with the new process. S-parameter measurements from 100 MHz up to 2 GHz have shown a capacitance tuning range higher than 100% with the double-air-gap architecture. The tuning range can be enlarged with a proper DC electrical bias of the capacitor electrodes. Finally, the reported results make the proposed MEMS tuneable capacitor a good candidate for above-IC integration in communications applications. © 2004 Elsevier B.V. All rights reserved.
Resumo:
We have designed and fabricated a broadband and compact polarisation selector using a photonic crystal at the junction of two intersecting active waveguides. The crystal shows >8dB polarisation selectivity over a 70nm range. © 2003 Optical Society of America.
Resumo:
We have fabricated a series of polymer stabilized chiral nematic test cells for use as flexoelectro-optic devices. The devices fabricated were based on commercial chiral nematic mixtures which were polymer stabilized so as to enhance the uniformity and stability of the uniform lying helix texture in the cells. During fabrication and test procedures a series of unusual scattering states have been observed within the devices at different viewing angles. The observations made so far indicate that the properties of the scattering state lies somewhere between the focal conic texture and the Grandjean or planar texture and that the devices exhibit both a helical pitch selective reflection and scattering effect. What is even more dramatic is that the wavelength selectivity of the scattering effect can be tuned by an applied field. In addition, we show that it is possible to achieve good uniform lying helix textures from such devices. Moreover, we show that in certain cases the spontaneous alignment of the helix in the plane of the device opens up the possibility of a new mode of switching. Flexoelectric, Redshift, Coloured scattering, Liquid crystal, Polymer-stabilized liquid-crystal;.