45 resultados para Earthquakes.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of high viscous pore fluid has been widely established to match the rate of excess pore pressure generation and subsequent dissipation in dynamic centrifuge tests. The appropriate viscosity is linked to the geometric and gravity scaling factors which corresponds to the use of pore fluid of 'N' cSt in a 'N'g centrifuge test. The use of either water (1 cSt) or pore fluid lower than 'N' cSt can influence the behaviour of soil liquefaction in a centrifuge test. In this paper, the floatation of a tunnel following soil liquefaction is investigated using pore fluids with two different viscosities. The results show that the uplift displacement of the tunnel is significantly affected by the pore fluid viscosity. © 2010 Taylor & Francis Group, London.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The failure of piled foundations has been observed in many earthquake events. The manner in which a pile is able to support its applied superstructure loading during an earthquake is not yet fully understood, particularly with respect to the shaft friction capacity. In this paper, new pile group is presented which has been instrumented to measure the shaft friction distribution along the length of a pile. In addition, this pile group is able to measure the pore pressures directly beneath the pile tips. The pile group was tested in dynamic centrifuge experiments and showed differing shaft friction behaviour in dense and loose soil layers as well as strong dilation beneath the pile tips at the start of earthquake loading. A reduction in shaft friction was observed after the earthquake due to soil down-drag. © 2010 Taylor & Francis Group, London.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The rocking response of structures subjected to strong ground motions is a problem of 'several scales'. While small structures are sensitive to acceleration pulses acting successively, large structures are more significantly affected by coherent low frequency components of ground motion. As a result, the rocking response of large structures is more stable and orderly, allowing effective isolation from the ground without imminent danger of overturning. This paper aims to characterize and predict the maximum rocking response of large and flexible structures to earthquakes using an idealized structural model. To achieve this, the maximum rocking demand caused by different earthquake records was evaluated using several ground motion intensity measures. Pulse-type records which typically have high peak ground velocity and lower frequency content caused large rocking amplitudes, whereas non-pulse type records caused random rocking motion confined to small rocking amplitudes. Coherent velocity pulses were therefore identified as the primary cause of significant rocking motion. Using a suite of pulse-type ground motions, it was observed that idealized wavelets fitted to velocity pulses can adequately describe the rocking response of large structures. Further, a parametric analysis demonstrates that pulse shape parameters affect the maximum rocking response significantly. Based on these two findings, a probabilistic analysis method is proposed for estimating the maximum rocking demand to pulse-type earthquakes. The dimensionless demand maps, produced using these methods, have predictive power in the near-field provided that pulse period and amplitude can be estimated a priori. Use of this method within a probabilistic seismic demand analysis framework is briefly discussed. © 2013 Springer Science+Business Media Dordrecht.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In situ densification is a popular technique to protect shallow foundations from the effects of earthquake-induced liquefaction, current design being based on semiempirical rules. Poor understanding of the mechanisms governing the performance of soil-structure systems during and after earthquakes inhibits the use of narrow densified zones, which could contribute to optimise the use of densification if the increase in post-earthquake settlement is restrained. Therefore this paper investigates the long-term behaviour of a footing built on densified ground and surrounded by liquefiable ground, centrifuge experiments being used to identify the mechanisms occurring in the ground during and after a seismic simulation. The differential excess pore pressure generated in the ground during the shaking and the processes of vertical stress concentration and subsequent redistribution observed under the footing dominate the system behaviour. The results enlighten the complex mechanisms determining the post-earthquake settlement when densification is carried out to mitigate liquefaction effects. The improvement in performance resulting from widening the zone of densification is rationally explained which encourages the development of new design concepts that may enhance the future use of densification as a liquefaction resistance measure. © 2007 Thomas Telford Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Residential RC framed structures suffered heavily during the 2001 Bhuj earthquake in Gujarat, India. These types of structures also saw severe damage in other earthquakes such as the 1999 Kocaeli earthquake in Turkey and 921 Ji-Ji earthquake in Taiwan. In this paper the seismic response of residential structures was investigated using physical modelling. Idealised soft storey and top heavy, two degrees of freedom (2DOF) portal frame structures were developed and tested on saturated and dry sand models at 25 g using the Schofield Centre 10-m Beam Centrifuge. It was possible to recreate observed field behaviour using these models. As observed in many of the recent earthquakes, soft storey structures were found to be particularly vulnerable to seismic loads. Elastic response spectra methods are often used in the design of simple portal frame structures. The seismic risk of these structures can be significantly increased due to modifications such as removal of a column or addition of heavy water tanks on the roof. The experimental data from the dynamic centrifuge tests on such soft storey or top-heavy models was used to evaluate the predictions obtained from the response spectra. Response spectra were able to predict seismic response during small to moderate intensity earthquakes, but became inaccurate during strong earthquakes and when soil structure interaction effects became important. Re-evaluation of seismic risk of such modified structures is required and time domain analyses suggested by building codes such as IBC, UBC or NEHRP may be more appropriate. © Springer 2006.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The seismic performance of waterfront cantilever sheet pile retaining walls is of continuing interest to geotechnical engineers as these structures suffer severe damage and even complete failure during earthquakes. This is often precipitated by liquefaction of the surrounding soil, either in the backfill or in front of the wall. This paper presents results from a series of small-scale plane strain models that were tested on a 1-g shaking table and recorded using a high-speed, high-resolution digital camera. The technique of Particle Image Velocimetry (PIV) was applied in order to allow the failure mechanisms to be visualised. It is shown that using PIV analyses it is possible to obtain failure mechanisms for a cantilever wall in liquefiable soil. These failure mechanisms are compared with those obtained for a cantilever wall in dry soil, previously carried out at a similar scale. It was observed that seismic liquefaction causes significant displacement in much larger zones of soil near the retaining wall compared to an equivalent dry case. The failure mechanism for a cantilever wall with liquefiable backfill, but with a remediated zone designed not to liquefy, is also presented and compared to the unremediated case.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes four centrifuge tests investigating the performance of non-structural inclined micro-piles as a liquefaction remediation method for existing buildings. Two soil profiles with the same superstructure founded on each were tested under earthquakes of different magnitudes and durations. The first profile consisted of a deep, homogeneous layer of loose, liquefiable sand. The second comprised a shallow layer of loose sand overlying dense sand. Centrifuge tests were carried out with and without inclined micro-piles in each soil profile. The superstructure was modelled as an idealised single degree of freedom (SDOF) system. It is found that the micro-piles have no detrimental effect on the performance of the structure during and after earthquakes. It is also possible that their presence may decrease structural settlements in earthquakes which cause liquefaction to a depth less than that of the improved zone. However, no conclusive evidence is obtained to show that the micro-piles significantly restrain lateral soil movement due to monotonic shearing from the structure or impede the migration of excess pore pressures from the free field to the foundation zone. Both these processes have critical effects on structural settlement. The use of inclined micro-piles for liquefaction remediation should therefore be considered with caution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Many piled foundations have been destroyed under significant cyclic loads in earthquakes. Centrifuge modelling of a single pile subjected to cyclic loads has been conducted to investigate the influence of cyclic loads on the axial performance of the single pile. Different pile installation procedures were applied to compare the axial behaviour of different piles under cyclic loads. Pile head permanent settlements accumulated due to cyclic axial loads, and these increased with the increasing load amplitude. Also the pile head axial secant stiffness decreased with the increasing number of axial load cycles, and with increasing amplitude. Furthermore, the axial pile performance is influenced significantly by different installation methods. © 2010 ASCE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

During earthquakes, hydrodynamic pressures are generated by the impounded reservoir on the dam face. The magnitude and distribution of the hydrodynamic pressures vary with factors such as frequency and intensity of earthquake-induced ground motion, depth of impounded reservoir, stiffness of dam and geological conditions. It is difficult to obtain experimental data on hydrodynamic pressures from the field owing to uncertainties associated with earthquake loading. This paper aims at using dynamic centrifuge modelling to measure hydrodynamic pressures behind both relatively stiff and flexible model dams. Comparisons of the experimental data with theoretical hydrodynamic pressures show that Westergaard's equation gives a conservative estimation of hydrodynamic pressures. Comparison with Chopra's method revealed that it underpredicts hydrodynamic pressures for low reservoir depths but gives reasonably good predictions for higher depths of reservoir. It is concluded that dynamic centrifuge modelling may be an effective experimental method to estimate the hydrodynamic pressures acting on a dam. © 2010 Thomas Telford Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Piles passing through sloping liquefiable deposits are prone to lateral loading if these deposits liquefy and flow during earthquakes. These lateral loads caused by the relative soil-pile movement will induce bending in the piles and may result in failure of the piles or excessive pile-head displacement. Whilst the weak nature of the flowing liquefied soil would suggest that only small loads would be exerted on the piles, it is known from case histories that piles do fail owing to the influence of laterally spreading soils. It will be shown, based on dynamic centrifuge test data, that dilatant behaviour of soil close to the pile is the major cause of these considerable transient lateral loads which are transferred to the pile. This paper reports the results of geotechnical centrifuge tests in which models of gently sloping liquefiable sand with pile foundations passing through them were subjected to earthquake excitation. The soil close to the pile was instrumented with pore-pressure transducers and contact stress cells in order to monitor the interaction between soil and pile and to track the soil stress state both upslope and downslope of the pile. The presence of instrumentation measuring pore-pressure and lateral stress close to the pile in the research described in this paper gives the opportunity to better study the soil stress state close to the pile and to compare the loads measured as being applied to the piles by the laterally spreading soils with those suggested by the JRA design code. This test data shows that lateral stresses much greater than one might expect from calculations based on the residual strength of liquefied soil may be applied to piles in flowing liquefied slopes owing to the dilative behaviour of the liquefied soil. It is shown at least for the particular geometry studied that the current JRA design code can be un-conservative by a factor of three for these dilation-affected transient lateral loads.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The seismic design for offshore foundations is based predominantly on experience onshore. This paper describes the results of dynamic centrifuge tests performed to validate the performance of a suction caisson installed in normally consolidated clay. The main objective is to evaluate the likely plastic displacement under different shaking levels. Permanent displacement results indicate that the displacements experienced are well within the allowable movement for the foundation considered, even though a strength based design approach would consider this to be a failure. Larger earthquakes are seen to produce comparatively smaller displacements. It is concluded that the when designing for seismic loading, if some displacement is permissible then a performance-based approach allowing some displacement proves significantly less conservative than a purely strength-based design. It is also concluded that dynamic response analyses should consider the strength of soil, as this can act as a fuse against large amplitude shear waves. © 2011 Taylor & Francis Group, London.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the framework of the Italian research project ReLUIS-DPC, a set of centrifuge tests were carried out at the Schofield Centre in Cambridge (UK) to investigate the seismic behaviour of tunnels. Four samples of dry sand were prepared at different densities, in which a small scale model of circular tunnel was inserted, instrumented with gauges measuring hoop and bending strains. Arrays of accelerometers in the soil and on the box allowed the amplification of ground motion to be evaluated; LVDTs measured the soil surface settlement. This paper describes the main results of this research, showing among others the evolution of the internal forces during the model earthquakes at significant locations along the tunnel lining. © 2010 Taylor & Francis Group, London.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The widespread use of piled foundations in areas prone to liquefaction has led to significant research being carried out to understand their behaviour during earthquakes. A key challenge inmodelling this problemin a centrifuge is the installation procedure, and in most dynamic centrifuge experiments piles are installed before the test commences, either pushing the piles at 1g, or fixing the piles in the model and the sand poured around them. In this paper, a series of dynamic centrifuge experiments are described in which a 2 × 2 pile group is pushed into the model before the test begins and also once the centrifuge has reached the test acceleration. The paper focuses on the key differences which were observed in the pile group's response to the earthquake motion, and in particular, the very different settlement responses of the pile groups.