31 resultados para Active power-factor correction


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, a beamforming correction for identifying dipole sources by means of phased microphone array measurements is presented and implemented numerically and experimentally. Conventional beamforming techniques, which are developed for monopole sources, can lead to significant errors when applied to reconstruct dipole sources. A previous correction technique to microphone signals is extended to account for both source location and source power for two-dimensional microphone arrays. The new dipole-beamforming algorithm is developed by modifying the basic source definition used for beamforming. This technique improves the previous signal correction method and yields a beamformer applicable to sources which are suspected to be dipole in nature. Numerical simulations are performed, which validate the capability of this beamformer to recover ideal dipole sources. The beamforming correction is applied to the identification of realistic aeolian-tone dipoles and shows an improvement of array performance on estimating dipole source powers. © 2008 Acoustical Society of America.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The performance of a series of near-UV (∼385 nm) emitting LEDs, consisting of high efficiency InGaN/AlInGaN QWs in the active region, was investigated. Significantly reduced roll-over of efficiency at high current density was found compared to InGaN/GaN LEDs emitting at a similar wavelength. The importance of optical cavity effects in flip-chip geometry devices has also been investigated. The light output was enhanced by more than a factor of 2 when the lightemitting region was located at an anti-node position with respect to a high reflectivity current injection mirror. A power of 0.49 mW into a numerical aperture of 0.5 was obtained for a junction area of 50μm in diameter and a current of 30 mA, corresponding to a radiance of 30 W/cm2/str.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new experimental articulated vehicle with computer-controlled suspensions is used to investigate the benefits of active roll control for heavy vehicles. The mechanical hardware, the instrumentation, and the distributed control architecture are detailed. A simple roll-plane model is developed and validated against experimental data, and used to design a controller based on lateral acceleration feedback. The controller is implemented and tested on the experimental vehicle. By tilting both the tractor drive axle and the trailer inwards, substantial reductions in normalized lateral load transfer are obtained, both in steady state and transient conditions. Power requirements are also considered. © IMechE 2005.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Based on a comprehensive theoretical optical orthogonal frequency division multiplexing (OOFDM) system model rigorously verified by comparing numerical results with end-to-end real-time experimental measurements at 11.25Gb/s, detailed explorations are undertaken, for the first time, of the impacts of various physical factors on the OOFDM system performance over directly modulated DFB laser (DML)-based, intensity modulation and direct detection (IMDD), single-mode fibre (SMF) systems without in-line optical amplification and chromatic dispersion compensation. It is shown that the low extinction ratio (ER) of the DML modulated OOFDM signal is the predominant factor limiting the maximum achievable optical power budget, and the subcarrier intermixing effect associated with square-law photon detection in the receiver reduces the optical power budget by at least 1dB. Results also indicate that, immediately after the DML in the transmitter, the insertion of a 0.02nm bandwidth optical Gaussian bandpass filter with a 0.01nm wavelength offset with respect to the optical carrier wavelength can enhance the OOFDM signal ER by approximately 1.24dB, thus resulting in a 7dB optical power budget improvement at a total channel BER of 1 × 10(-3).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper an Active Voltage Control (AVC) technique is presented, for series connection of insulated-gate-bipolar-transistors (IGBT) and control of diode recovery. The AVC technique can control the switching trajectory of an IGBT according to a pre-set reference signal. In series connections, every series connected IGBT follows the reference and so that the dynamic voltage sharing is achieved. For the static voltage balancing, the AVC technique can clamp the highest collector-to-emitter voltage to a pre-set clamping voltage level. By selecting the value of the clamping voltage, the difference among series connected IGBTs can be controlled in an accepted range. Another key advantage for AVC is that by changing the reference signal at turn-on, the diode recovery can be optimized. © 2011 EPE Association - European Power Electr.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With series insulated-gate bipolar transistor (IGBT) operation, well-matched gate drives will not ensure balanced dynamic voltage sharing between the switching devices. Rather, it is IGBT parasitic capacitances, mainly gate-to-collector capacitance Cgc, that dominate transient voltage sharing. As Cgc is collector voltage dependant and is significantly larger during the initial turn-off transition, it dominates IGBT dynamic voltage sharing. This paper presents an active control technique for series-connected IGBTs that allows their dynamic voltage transition dV\ce/dt to adaptively vary. Both switch ON and OFF transitions are controlled to follow a predefined dVce/dt. Switching losses associated with this technique are minimized by the adaptive dv /dt control technique incorporated into the design. A detailed description of the control circuits is presented in this paper. Experimental results with up to three series devices in a single-ended dc chopper circuit, operating at various low voltage and current levels, are used to illustrate the performance of the proposed technique. © 2012 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We offer a solution to the problem of efficiently translating algorithms between different types of discrete statistical model. We investigate the expressive power of three classes of model-those with binary variables, with pairwise factors, and with planar topology-as well as their four intersections. We formalize a notion of "simple reduction" for the problem of inferring marginal probabilities and consider whether it is possible to "simply reduce" marginal inference from general discrete factor graphs to factor graphs in each of these seven subclasses. We characterize the reducibility of each class, showing in particular that the class of binary pairwise factor graphs is able to simply reduce only positive models. We also exhibit a continuous "spectral reduction" based on polynomial interpolation, which overcomes this limitation. Experiments assess the performance of standard approximate inference algorithms on the outputs of our reductions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Active Voltage Control (AVC) is an implementation of classic Proportional-Derivative (PD) control and multi-loop feedback control to force an IGBT to follow a pre-set switching trajectory. Previously, AVC was mainly used for controlling series-connected IGBTs in order to enable voltage balance between IGBTs. In this paper, the nonlinear IGBT turn-off transient is further discussed and the turnoff of a single IGBT under AVC is further optimised in order to meet the demand of Power Electronic Building Block (PEBB) applications. © 2013 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High-performance power switching devices (IGBT/MOSFET) realise high-performance power converters. Unfortunately, with a high switching speed of the IGBT or MOSFET freewheel diode chopper cell, the circuit has intrinsic sources of high-level EMI. Therefore, costly EMI filters or shielding are normally demanded on the load and supply side. Although an S-shaped voltage transient with a high order of derivation eliminates the discontinuity and could suppress HF spectrum of EMI emissions, a practical control scheme is still under development. In this paper, Active Voltage Control (AVC) is applied to successfully define IGBT switching dynamics with a smoothed Gaussian waveform so a reduced EMI can be achieved without extra EMI suppression devices. © 2013 IEEE.