256 resultados para CONDON ACTIVE VIBRATIONS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cascaded 4×4 SOA switches with on-chip power monitoring exhibit potential for lowpower 16×16 integrated switches. Cascaded operation at 10Gbit/s with an IPDR of 8.5dB and 79% lower power consumption than equivalent all-active switches is reported © 2013 OSA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An Agat-SF linear-scan streak image-converter camera was used to record output pulses of 2. 7 psec duration generated by an injection laser with an external dispersive resonator operated in the active mode-locking regime. The duration of the pulses was determined by the reciprocal of the spectral width and the product of the duration and the spectral width was 0. 30.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a complete system for expressive visual text-to-speech (VTTS), which is capable of producing expressive output, in the form of a 'talking head', given an input text and a set of continuous expression weights. The face is modeled using an active appearance model (AAM), and several extensions are proposed which make it more applicable to the task of VTTS. The model allows for normalization with respect to both pose and blink state which significantly reduces artifacts in the resulting synthesized sequences. We demonstrate quantitative improvements in terms of reconstruction error over a million frames, as well as in large-scale user studies, comparing the output of different systems. © 2013 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Active Voltage Control (AVC) is an implementation of classic Proportional-Derivative (PD) control and multi-loop feedback control to force an IGBT to follow a pre-set switching trajectory. Previously, AVC was mainly used for controlling series-connected IGBTs in order to enable voltage balance between IGBTs. In this paper, the nonlinear IGBT turn-off transient is further discussed and the turnoff of a single IGBT under AVC is further optimised in order to meet the demand of Power Electronic Building Block (PEBB) applications. © 2013 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-performance power switching devices (IGBT/MOSFET) realise high-performance power converters. Unfortunately, with a high switching speed of the IGBT or MOSFET freewheel diode chopper cell, the circuit has intrinsic sources of high-level EMI. Therefore, costly EMI filters or shielding are normally demanded on the load and supply side. Although an S-shaped voltage transient with a high order of derivation eliminates the discontinuity and could suppress HF spectrum of EMI emissions, a practical control scheme is still under development. In this paper, Active Voltage Control (AVC) is applied to successfully define IGBT switching dynamics with a smoothed Gaussian waveform so a reduced EMI can be achieved without extra EMI suppression devices. © 2013 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: After investing significant amounts of time and money in conducting formal risk assessments, such as root cause analysis (RCA) or failure mode and effects analysis (FMEA), healthcare workers are left to their own devices in generating high-quality risk control options. They often experience difficulty in doing so, and tend toward an overreliance on administrative controls (the weakest category in the hierarchy of risk controls). This has important implications for patient safety and the cost effectiveness of risk management operations. This paper describes a before and after pilot study of the Generating Options for Active Risk Control (GO-ARC) technique, a novel tool to improve the quality of the risk control options generation process. OUTCOME MEASURES: The quantity, quality (using the three-tiered hierarchy of risk controls), variety, and novelty of risk controls generated. RESULTS: Use of the GO-ARC technique was associated with improvement on all measures. CONCLUSIONS: While this pilot study has some notable limitations, it appears that the GO-ARC technique improved the risk control options generation process. Further research is needed to confirm this finding. It is also important to note that improved risk control options are a necessary, but not sufficient, step toward the implementation of more robust risk controls.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Active Voltage Control (AVC) is an implementation of classic Proportional-Derivative (PD) control and multi-loop feedback control to force IGBT to follow a pre-set switching trajectory. The initial objective of AVC was mainly to synchronise the switching of IGBTs connected in series so as to realise voltage balancing between devices. For a single IGBT switching, the AVC reference needs further optimisation. Thus, a predictive manner of AVC reference generation is required to cope with the nonlinear IGBT switching parameters while performing low loss switching. In this paper, an improved AVC structure is adopted along with a revised reference which accommodates the IGBT nonlinearity during switching and is predictive based on current being switched. Experimental and simulation results show that close control of a single IGBT switching is realised. It is concluded that good performance can be obtained, but the proposed method needs careful stability analysis for parameter choice. © 2013 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper looks at active control of the normal shock wave/turbulent boundary layer interaction (SBLI) using smart flap actuators. The actuators are manufactured by bonding piezoelectric material to an inert substrate to control the bleed/suction rate through a plenum chamber. The cavity provides communication of signals across the shock, allowing rapid thickening of the boundary layer approaching the shock, which splits into a series of weaker shocks forming a lambda shock foot, reducing wave drag. Active control allows optimum control of the interaction, as it would be capable of positioning the control region around the original shock position and control the rate of mass transfer. © 2004 by the American Institute of Aeronautics and Astronautics, Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a method for producing dense Active Appearance Models (AAMs), suitable for video-realistic synthesis. To this end we estimate a joint alignment of all training images using a set of pairwise registrations and ensure that these pairwise registrations are only calculated between similar images. This is achieved by defining a graph on the image set whose edge weights correspond to registration errors and computing a bounded diameter minimum spanning tree (BDMST). Dense optical flow is used to compute pairwise registration and we introduce a flow refinement method to align small scale texture. Once registration between training images has been established we propose a method to add vertices to the AAM in a way that minimises error between the observed flow fields and a flow field interpolated between the AAM mesh points. We demonstrate a significant improvement in model compactness using the proposed method and show it dealing with cases that are problematic for current state-of-the-art approaches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a novel vertically-coupled active-passive integration architecture that provides an order of magnitude reduction in coupling coefficient variation between misaligned waveguides when compared with a conventional vertically-coupled structure. © 2005 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a novel vertically-coupled active-passive integration architecture that provides an order of magnitude reduction in coupling coefficient variation between misaligned waveguides when compared with a conventional vertically-coupled structure. © 2005 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a novel vertically-coupled active-passive integration architecture that provides an order of magnitude reduction in coupling coefficient variation between misaligned waveguides when compared with a conventional vertically-coupled structure. © 2005 Optical Society of America.