204 resultados para Source separation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a map of the transformation of energy in China as a Sankey diagram. After a review of previous work, and a statement of methodology, our main work has been the identification, evaluation, and treatment of appropriate data sources. This data is used to construct the Sankey diagram, in which flows of energy are traced from energy sources through end-use conversion devices, passive systems and final services to demand drivers. The resulting diagram provides a convenient and clear snapshot of existing energy transformations in China which can usefully be compared with a similar global analysis and which emphasises the potential for improvements in energy efficiency in 'passive systems'. More broadly, it gives a basis for examining and communicating future energy scenarios, including changes to demand, changes to the supply mix, changes in efficiency and alternative provision of existing services. © 2012 Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Opengazer is an open source application that uses an ordinary webcam to estimate head pose, facial gestures, or the direction of your gaze. This information can then be passed to other applications. For example, used in conjunction with Dasher, opengazer allows you to write with your eyes. Opengazer aims to be a low-cost software alternative to commercial hardware-based eye trackers. The first version of Opengazer was developed by Piotr Zieliński, supported by Samsung and the Gatsby Charitable Foundation. Research and development for Opengazer has been continued by Emli-Mari Nel, and was supported until 2012 by the European Commission in the context of the AEGIS project, and also by the Gatsby Charitable Foundation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experiments are conducted to examine the mechanisms behind the coupling between corner separation and separation away from the corner when holding a high-Machnumber M∞ = 1.5 normal shock in a rectangular channel. The ensuing shock wave interaction with the boundary layer on the wind tunnel floor and in the corners was studied using laser Doppler anemometry, Pitot probe traverses, pressure sensitive paint and flow visualization. The primary mechanism explaining the link between the corner separation size and the other areas of separation appears to be the generation of compression waves at the corner, which act to smear the adverse pressure gradient imposed upon other parts of the flow. Experimental results indicate that the alteration of the -region, which occurs in the supersonic portion of the shock wave/boundary layer interaction (SBLI), is more important than the generation of any blockage in the subsonic region downstream of the shock wave. © Copyright 2012 Cambridge University Press.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We derive a random-coding upper bound on the average probability of error of joint source-channel coding that recovers Csiszár's error exponent when used with product distributions over the channel inputs. Our proof technique for the error probability analysis employs a code construction for which source messages are assigned to subsets and codewords are generated with a distribution that depends on the subset. © 2012 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Space heating accounts for a large portion of the world's carbon dioxide emissions. Ground Source Heat Pumps (GSHPs) are a technology which can reduce carbon emissions from heating and cooling. GSHP system performance is however highly sensitive to deviation from design values of the actual annual energy extraction/rejection rates from/to the ground. In order to prevent failure and/or performance deterioration of GSHP systems it is possible to incorporate a safety factor in the design of the GSHP by over-sizing the ground heat exchanger (GHE). A methodology to evaluate the financial risk involved in over-sizing the GHE is proposed is this paper. A probability based approach is used to evaluate the economic feasibility of a hypothetical full-size GSHP system as compared to four alternative Heating Ventilation and Air Conditioning (HVAC) system configurations. The model of the GSHP system is developed in the TRNSYS energy simulation platform and calibrated with data from an actual hybrid GSHP system installed in the Department of Earth Science, University of Oxford, UK. Results of the analysis show that potential savings from a full-size GSHP system largely depend on projected HVAC system efficiencies and gas and electricity prices. Results of the risk analysis also suggest that a full-size GSHP with auxiliary back up is potentially the most economical system configuration. © 2012 Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider a large scale network of interconnected heterogeneous dynamical components. Scalable stability conditions are derived that involve the input/output properties of individual subsystems and the interconnection matrix. The analysis is based on the Davis-Wielandt shell, a higher dimensional version of the numerical range with important convexity properties. This can be used to allow heterogeneity in the agent dynamics while relaxing normality and symmetry assumptions on the interconnection matrix. The results include small gain and passivity approaches as special cases, with the three dimensional shell shown to be inherently connected with corresponding graph separation arguments. © 2012 Society for Industrial and Applied Mathematics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We examine the role of heat source geometry in determining rates of airflow and thermal stratification in natural displacement ventilation flows. We modify existing models to account for heat sources of finite (non-zero) area, such as formed by a sun patch warming the floor of a room. Our model allows for predictions of the steady stratification and ventilation flow rates that develop in a room due to a circular heat source at floor level. We compare our theoretical predictions with predictions for the limiting cases of a point source of heat (yielding a stratified interior), and a uniformly heated floor (yielding a mixed interior). Our theory shows a smooth transition between these two limits, which themselves result in extremes of ventilation, as the ratio of the heat source radius to the room height increases. Our model for the transition from displacement to mixing ventilation is compared to previous work and demonstrates that the transition can occur for smaller sources than previously thought, particularly for rooms with large floor area compared to ceiling height. © 2009 Elsevier Ltd.