163 resultados para ‘Keep-out’ signal
Resumo:
Energy performance labelling and certification have been introduced widely to address market failures affecting the uptake of energy efficient technologies, by providing a signal to support decision making during contracting processes. The UK has recently introduced the Energy Performance Certificate (EPC) as a signal of building energy performance. The aims of this article are: to evaluate how valid EPC's are signals of occupier satisfaction with office facilities; and to understand whether occupant attitudes towards environmental issues have affected commercial office rental values. This was achieved by surveying occupant satisfaction with their workplaces holistically using a novel multi-item rating scale which gathered 204 responses. Responses to this satisfaction scale were matched with the corresponding EPC and rental value of occupier's workplaces. The satisfaction scale was found to be both a reliable and valid measure. The analysis found that EPC asset rating correlates significantly with occupant satisfaction with all facility attributes. Therefore, EPC ratings may be considered valid signals of overall facility satisfaction within the survey sample. Rental value was found to correlate significantly only with facility aesthetics. No evidence suggests rental value has been affected by occupants' perceptions towards the environmental impact of facilities. © 2013 The Authors.
Resumo:
MIMO DSP is employed to improve the performance of degenerate mode-group division multiplexing in 8 km of conventional GI-MMF. Compensation of the mode coupling, induced by the launch and propagation, between and inside each degenerate mode-group is investigated in order to reduce the DSP complexity. © 2013 IEEE.
Resumo:
Screech is a high frequency oscillation that is usually characterized by instabilities caused by large-scale coherent flow structures in the wake of bluff-body flameholders and shear layers. Such oscillations can lead to changes in flame surface area which can cause the flame to burn unsteadily, but also couple with the acoustic modes and inherent fluid-mechanical instabilities that are present in the system. In this study, the flame response to hydrodynamic oscillations is analyzed in a controlled manner using high-fidelity Computational Fluid Dynamics (CFD) with an unsteady Reynolds-averaged Navier-Stokes approach. The response of a premixed flame with and without transverse velocity forcing is analyzed. When unforced, the flame is shown to exhibit a self-excitation that is attributed to the anti-symmetric shedding of vortices in the wake of the flameholder. The flame is also forced using two different kinds of low-amplitude out-of-phase inlet velocity forcing signals. The first forcing method is harmonic forcing with a single characteristic frequency, while the second forcing method involves a broadband forcing signal with frequencies in the range of 500 - 1000 Hz. For the harmonic forcing method, the flame is perturbed only lightly about its mean position and exhibits a limit cycle oscillation that is characteristic of the forcing frequency. For the broadband forcing method, larger changes in the flame surface area and detachment of the flame sheet can be seen. Transition to a complicated trajectory in the phase space is observed. When analyzed systematically with system identification methods, the CFD results, expressed in the form of the Flame Transfer Function (FTF) are capable of elucidating the flame response to the imposed perturbation. The FTF also serves to identify, both spatially and temporally, regions where the flame responds linearly and nonlinearly. Locking-in between the flame's natural self-excited frequency and the subharmonic frequencies of the broadband forcing signal is found to alter the dynamical behaviour of the flame. Copyright © 2013 by ASME.
Resumo:
We experimentally demonstrate the use of an on-chip integrated Schottky plasmonic detector for testing, monitoring and tapping signals in plasmonic and photonic devices. Theoretical model and measurement of external and integrated devices will be presented. © OSA 2013.
Resumo:
We experimentally demonstrate the use of an on-chip integrated Schottky plasmonic detector for testing, monitoring and tapping signals in plasmonic and photonic devices. Theoretical model and measurement of external and integrated devices will be presented. © OSA 2013.
Resumo:
We experimentally demonstrate the use of an on-chip integrated Schottky plasmonic detector for testing, monitoring and tapping signals in plasmonic and photonic devices. Theoretical model and measurement of external and integrated devices will be presented. © OSA 2013.
Resumo:
We demonstrate an uncooled WDM system using standard WDM components and receiver signal processing, with a different number of receivers to transmitters, to allow wide temperature drift of the transmitter lasers. A 100 Gb/s 8-wavelength demonstrator has been developed, which proves the feasibility of the approach over 25 km of SMF. © 2012 Optical Society of America.
Resumo:
This paper outlines necessary and sufficient conditions for network reconstruction of linear, time-invariant systems using data from either knock-out or over-expression experiments. These structural system perturbations, which are common in biological experiments, can be formulated as unknown system inputs, allowing the network topology and dynamics to be found. We assume that only partial state measurements are available and propose an algorithm that can reconstruct the network at the level of the measured states using either time-series or steady-state data. A simulated example illustrates how the algorithm successfully reconstructs a network from data. © 2013 EUCA.
Resumo:
In the present paper, highly porous fibre networks made of 316L fibres, with different fibre volume fractions, are characterized in terms of network architecture, elastic constants and fracture energies. Elastic constants are measured using quasi-static mechanical and modal vibration testing, yielding local and globally averaged properties, respectively. Differences between quasi-static and dynamic elastic constants are attributed to through-thickness shear effects. Regardless of the method employed, networks show signs of material inhomogeneity at high fibre densities, in agreement with X-ray nanotomography results. Strong auxetic (or negative Poisson's ratio) behaviour is observed in the through-thickness direction, which is attributed to fibre kinking induced during processing. Measured fracture energies are compared with model predictions incorporating information about in-plane fibre orientation distribution, fibre volume fraction and single fibre work of fracture. Experimental values are broadly consistent with model predictions, based on the assumption that this energy is primarily associated with plastic deformation of individual fibres within a process zone of the same order as the inter-joint spacing. © 2013 Published by Elsevier Ltd. on behalf of Acta Materialia Inc. All rights reserved.
Resumo:
Two recent studies provide important insights into the organization of premotor circuitries, showing that control of highly-specific skilled forelimb movements, such as reaching and grasping, requires activation of specific subpopulations of neurons in the brainstem and spinal cord.
Resumo:
Optical technologies have received large interest in recent years for use in board-level interconnects. Polymer multimode waveguides in particular, constitute a promising technology for high-capacity optical backplanes as they can be cost-effectively integrated onto conventional printed circuit boards (PCBs). This paper presents the first optical backplane demonstrator based on the use of PCB-integrated polymer multimode waveguides and a regenerative shared bus architecture. The backplane demonstrator is formed with commercially-available low-cost electronic and photonic components onto conventional FR4 substrates and comprises two opto-electronic (OE) bus modules interconnected via a prototype regenerator unit. The system enables interconnection between the connected cards over four optical channels, each operating at 10 Gb/s. Bus extension is achieved by cascading OE bus modules via 3R regenerator units, overcoming therefore the inherent limitation of optical bus topologies in the maximum number of cards that can be connected to the bus. Details of the design, fabrication, and assembly of the different parts of this optical bus backplane are presented and related optical and data transmission characterisation studies are reported. The optical layer of the OE bus modules comprises a four-channel three-card waveguide layout that is compatible with VCSEL/PD arrays and ribbon fibres. All on-board optical paths exhibit insertion losses below 13 dB and intra-channel crosstalk lower than -29 dB. The robustness of the signal distribution from the bus inputs to all respective bus output ports in the presence of input misalignment is demonstrated, while 1 dB input alignment tolerances of approximately ±10 μm are obtained. The electrical layer of the OE bus modules comprises the essential driving circuitry for 1×4 VCSEL and PD arrays and the corresponding control and power regulation circuits. The interface between the optical and electrical layers of the bus modules is achieved with simple OE connectors that enable end-fired optical coupling into and out of the on-board polymer waveguides. The backplane demonstrator achieves error-free (BER < 10-12) 10 Gb/s data transmission over each optical channel, enabling therefore, an aggregate interconnection capacity of 40 Gb/s between any connected cards. © 1983-2012 IEEE.
Resumo:
A 3x3 SOA-based switch is demonstrated for routing both radio-over-fiber and digital signals simultaneously. High extinction ratio digital baseband signals are transmitted and sufficient linearity is found for high performance RF signal distribution. © 2006 Optical Society of America.