192 resultados para DG-TAURI


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The performance of 40 Gbit/s optical time-division multiplexed (OTDM) communication systems can be severely limited when the extinction ratio of the optical pulses is low. This is a consequence of the coherent interference noise between individual OTDM channels. When taken alone, the multiple quantum well-distributed feedback laser+dispersion compensating fiber source exhibits a relatively poor extinction ratio which impairs its potential for use in a 40 Gbit/s OTDM system. However, with the addition of an electroabsorption modulator to suppress the pulse pedestals to better than 30 dB extinction, coherent interference noise is reduced, the bit-error-rate performance is greatly improved, and the source shows good potential for 40 Gbit/s OTDM communication.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A GaAs Vertical Cavity Surface Emitting Laser (VCSEL) that generates controlled modes offset from the center is described. The device is modulated with a 27-1 pseudo-random bit sequence and its output is transmitted along a 1 km length of multimode fiber (MMF). Open eyes are obtained for data rates as high as 1.4Gb/s. The transmission bandwidth increases by a factor of 4 over over-filled launch (OFL). This enhancement is stable against environment influences on the fiber.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The usage of subcarrier multiplexing (SCM) techniques to allow link transmission in excess of the specified fiber bandwidth is described. A series of 200-Mbit/s channels with carrier frequencies of up to more than twenty times the 3-dB fiber bandwidth have been successfully used, the maximum being limited by the available electronics. To assess the transmission of the fiber, digitally modulated channels are placed on high frequency carrier signals and then used to modulate a vertical-cavity surface-emitting lasers (VCSEL).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Etched VCSEL sources are reported which avoid bandwidth collapse in multimode fibre using a simple coupling technique to control the launch. These devices have allowed better than over-filled launch bandwidth for alignment tolerances of ±7 microns.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The paper describes a model for a 6-phase induction motor driven by an inverter operating in a 6-pulse (square wave) mode. The model is implemented and performance, in terms of torque, current, efficiency and pulsating torque, compared to the performance of a 3-phase motor (both sine and 6-pulse supplied). The models are verified experimentally, in particular the efficiency performance, and it is illustrated that the improvement in inverter efficiency when in 6-pulse operating mode may improve the performance of the overall system. © 2005 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The complications of impaction bone grafting in revision hip replacement includes fracture of he femur and subsidence of the prosthesis. In this in vitro study we aimed to investigate whether the use of vibration, combined with a perforated tamp during the compaction of morsellised allograft would reduce peak loads and hoop strains in the femur as a surrogate marker of the risk of fracture and whether it would also improve graft compaction and prosthetic stability. We found that the peak loads and hoop strains transmitted to the femoral cortex during graft compaction and subsidence of the stem in subsequent mechanical testing were reduced. This innovative technique has the potential to reduce the risk of intra-operative fracture and to improve graft compaction and therefore prosthetic stability. © 2007 British Editorial Society of Bone and Joint Surgery.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: When fresh morselized graft is compacted, as in impaction bone-grafting for revision hip surgery, fat and marrow fluid is either exuded or trapped in the voids between particles. We hypothesized that the presence of incompressible fluid damps and resists compressive forces during impaction and prevents the graft particles from moving into a closer formation, thus reducing the graft strength. In addition, viscous fluid such as fat may act as an interparticle lubricant, thus reducing the interlocking of the particles. METHODS: We performed mechanical shear testing in the laboratory with use of fresh-frozen human femoral-head allografts that had been passed through different orthopaedic bone mills to produce graft of differing particle-size distributions (grading). RESULTS: After compaction of fresh graft, fat and marrow fluid continued to escape on application of normal loads. Washed graft, however, had little lubricating fluid and better contact between the particles, increasing the shear resistance. On mechanical testing, washed graft was significantly (p < 0.001) more resistant to shearing forces than fresh graft was. This feature was consistent for different bone mills that produced graft of different particle-size distributions and shear strengths. CONCLUSIONS: Removal of fat and marrow fluid from milled human allograft by washing the graft allows the production of stronger compacted graft that is more resistant to shear, which is the usual mode of failure. Further research into the optimum grading of particle sizes from bone mills is required.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Vibration is commonly used in civil engineering applications to efficiently compact aggregates. This study examined the effect of vibration and drainage on bone graft compaction and cement penetration in an in vitro femoral impaction bone grafting model with the use of 3-dimensional micro-computed tomographic imaging. Three regions were analyzed. In the middle and proximal femoral regions, there was a significant increase in the proportion of bone grafts with a reciprocal reduction in water and air in the vibration-assisted group (P < .01) as compared with the control group, suggesting tighter graft compaction. Cement volume was also significantly reduced in the middle region in the vibration-assisted group. No difference was observed in the distal region. This study demonstrates the value of vibration and drainage in bone graft compaction, with implications therein for clinical application and outcome.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: When fresh morselized graft is compacted, as in impaction bone-grafting for revision hip surgery, fat and marrow fluid is either exuded or trapped in the voids between particles. We hypothesized that the presence of incompressible fluid damps and resists compressive forces during impaction and prevents the graft particles from moving into a closer formation, thus reducing the graft strength. In addition, viscous fluid such as fat may act as an interparticle lubricant, thus reducing the interlocking of the particles. Methods: We performed mechanical shear testing in the laboratory with use of fresh-frozen human femoral-head allografts that had been passed through different orthopaedic bone mills to produce graft of differing particle-size distributions (grading). Results: After compaction of fresh graft, fat and marrow fluid continued to escape on application of normal loads. Washed graft, however, had little lubricating fluid and better contact between the particles, increasing the shear resistance. On mechanical testing, washed graft was significantly (p < 0.001) more resistant to shearing forces than fresh graft was. This feature was consistent for different bone mills that produced graft of different particle-size distributions and shear strengths. Conclusions: Removal of fat and marrow fluid from milled human allograft by washing the graft allows the production of stronger compacted graft that is more resistant to shear, which is the usual mode of failure. Further research into the optimum grading of particle sizes from bone mills is required. Clinical Relevance: Understanding the mechanical properties of milled human allograft is important when impaction grafting is used for mechanical support. A simple means of improving the mechanical strength of graft produced by currently available bone mills, including an intraoperative washing technique, is described.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Orthogonal multipulse modulation is demonstrated to allow ≈30 Gb/s real-time transmission over multimode fibre using an 850 nm VCSEL. The scheme eases considerably component bandwidth requirements compared with conventional NRZ modulation. © 2011 OSA.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

On-body sensor systems for sport are challenging since the sensors must be lightweight and small to avoid discomfort, and yet robust and highly accurate to withstand and capture the fast movements associated with sport. In this work, we detail our experience of building such an on-body system for track athletes. The paper describes the design, implementation and deployment of an on-body sensor system for sprint training sessions. We autonomously profile sprints to derive quantitative metrics to improve training sessions. Inexpensive Force Sensitive Resistors (FSRs) are used to capture foot events that are subsequently analysed and presented back to the coach. We show how to identify periods of sprinting from the FSR data and how to compute metrics such as ground contact time. We evaluate our system using force plates and show that millisecond-level accuracy is achievable when estimating contact times. © 2012 Elsevier B.V. All rights reserved.