121 resultados para offshore wind farm
Resumo:
Offshore wind has enormous worldwide potential to generate increasing amounts of clean, renewable energy. Monopile foundations are considered to be viable in supporting larger offshore wind turbines in shallow to medium depth waters. In this paper, the lateral and axial response of monopiles installed in undrained clays of varying shear strength and stiffness is investigated using three-dimensional finite element analysis. A combination of axial and lateral loads expected at an offshore wind farm located in a water depth of 30 m has been used in the analysis. Numerically derived monopile axial capacities will be compared to those calculated using an established method in the literature. In addition, the lateral monopile capacity will be determined at ultimate limit state and compared to that at the serviceability limit state. Through a parametric study, it will be shown that with the exception of extremely high axial loads that border on monopile axial capacities, variation in axial loads does not have a significant effect on the ultimate lateral capacity and lateral displacement of monopiles. © 2013 Indian Geotechnical Society.
Resumo:
Monopile foundations, currently designed using the p-y method, are technically viable in supporting larger offshore wind turbines in waters to a depth of 30 m. The p-y method was developed to better understand the behavior of laterally loaded long slender piles required for the offshore oil and gas installations. The lateral load-deformation behavior of two monopiles, 5 and 7.5 m dia, installed in soft clays of varying undrained shear strength and stiffness, was studied. A combination of axial and lateral loads expected at an offshore wind farm location with a water depth of 30 m was used in the analysis. It was established that the Matlock (1970) p-y curves are too soft and under-estimate the ultimate soil reaction at all depths except at the monopile tip. At the pile tip, the base shear was not accounted for in the p-y curves, hence resulting in the over-estimation of the soil reaction. Consequently, the Matlock (1970) p-y formulation significantly underestimates the monopile ultimate lateral capacity. The use of the Matlock (1970) p-y method would result in over-conservative designs of monopiles for offshore wind turbines. This is an abstract of a paper presented at the Offshore Technology Conference (Houston, TX 5/6-9/2013).
Resumo:
Wind power generation as one of the most popular renewable energy applications is absorbing more and more attention all over the world. However, output power fluctuations of wind farm due to random variations of wind speed can cause network frequency and voltage flicker in power systems. The power quality consequently declines, particularly in an isolated power system such as the power system in a remote community or a small island. This paper proposes an application of superconducting magnetic energy storage (SMES) to minimize output fluctuations of an isolated power system with wind farm. The isolated power system is fed by a diesel generator and a wind generator consisting of a wind turbine and squirrel cage induction machine. The control strategy is detailed and the proposed system is evaluated by simulation in Matlab/Simulink.
Resumo:
Offshore wind turbines impose unique combinations of loads on their foundations. They impose large lateral loads in relation to vertical loading which must be resisted, but are also subject to approximately a million cycles of loading through their design life. As the performance of these systems is dominated by their dynamic response, the stiffness of the foundations becomes critical in design. Conventional design codes which are conservative by virtue of predicting a lower stiffness than might be observed in practice may not be conservative for these problems. By utilizing centrifuge modeling the behaviour of monopile foundations in both sands and clays under cyclic loading can be investigated in order to predict the dynamic behaviour of these systems. © 2010 Taylor & Francis Group, London.
Resumo:
This paper proposes a magnetic circuit model (MCM) for the design of a brushless doubly-fed machine (BDFM). The BDFM possesses advantages in terms of high reliability and reduced gearbox stages, and it requires a fractionally-rated power converter. This makes it suitable for utilization in offshore wind turbines. It is difficult for conventional design methods to calculate the flux in the stator because the two sets of stator windings, which have different pole number, form a complex flux pattern which is not easily determined using common analytical approaches. However, it is advantageous to predict the flux density in the teeth and air-gap at the initial design stage for sizing purposes without recourse finite element analysis. Therefore a magnetic circuit model is developed in this paper to calculate the flux density. A BDFM is used as a case study with FEA validation. © 1965-2012 IEEE.
Resumo:
Offshore wind capacity is expected to grow exponentially over the next decade resulting in the production of a considerable amount of renewable energy. Monopiles are currently the most popular type of foundation for supporting offshore wind turbines in shallow to medium depth waters. In this paper, the load-deformation response of a 3.8 m diameter monopile installed in soft clays when subjected to axial and lateral loading is investigated using centrifuge testing and soil pore-fluid coupled three-dimensional finite element analysis. Monopile deformation is principally assessed in terms of its lateral displacements and bending moments. Its behaviour as a short rigid pile is discussed using concepts such as its rotation at mudline and the pile depth at which pivoting occurs. © 2014 Taylor & Francis Group.
Resumo:
The monopile is at present the most widely applied foundation concept for offshore wind turbines. Monopiles are designed utilising the well-established p-y method. Despite being well-established, there are multiple issues and limitations regarding its use. Investigation into the lateral behaviour of monopiles was carried out by performing monotonic and cyclic lateral load tests on an aluminium model monopile in the centrifuge. The monotonic responses and the behaviour of the monopile are described. Differences between the experimental and DNV design p-y curves and their implications are discussed. Efforts to characterise the shear force acting at the pile toe are also discussed. The results highlight the possible deficiencies of utilising the conventional DNV design p-y curves to design monopiles to resist cyclic lateral loads and the importance of research into the cyclic loading behaviour of monopiles to better improve their design to resist long-term cyclic loads. © 2014 Taylor & Francis Group.
Resumo:
Monopiles supporting offshore wind turbines are subjected to cyclic lateral loading. The properties of the applied cyclic lateral load are known to have an effect on the accumulation of permanent displacement and rotation at the pile head. The results of centrifuge testing on model piles show that certain loading regimes lead to the development of locked in soil stresses around the pile. These locked in soil stresses change the stiffness of the monopile response to cyclic lateral loading and the natural frequency of the pile-soil system. © 2014 Taylor & Francis Group.
Resumo:
The Brushless Doubly-Fed Machine (BDFM) is attractive for use in wind turbines, especially offshore, as it offers high reliability by virtue of the absence of brushgear. Critical issues in the use of the BDFM in this role at a system level include the appropriate mode of operation, the sizing of associated converter and the control of the machine. At a machine level, the design of the machine and the determination of its ratings are important. Both system and machine issues are reviewed in the light of recent advances in the study of the BDFM, and preliminary comparisons are made with the well-established doubly fed wound rotor induction generator. © 2006 IEEE.